The very high accuracy 3-channel thermometer MilliK is capable of performances of 0.003°C with SPRTs and PRTs and high accuracy measurements with thermistors, thermocouples and even 4-20 mA process inputs. The number of channels can be expanded to 33 inputs with the MillisKanner. Description The MilliK precision thermometer sets a new standard for the high accuracy measurement and calibration of Platinum resistance thermometers, thermistors, thermocouple and process instrumentation (4-20 mA) over the range -270°C to 1820°C. In addition to low uncertainty measurements from reference standards...
Open the catalog to page 2• SPRTs, PRTs, Thermistors, Thermocouples and 4 - 20mA Process Inputs • Controls calibration baths and dry blocks • Long term data acquisition • Eliminates unwanted thermal EMFs and lead wire errors • Galvanically isolated inputs • Connectivity: 2 serial interfaces, Ethernet and USB host
Open the catalog to page 3Specifications Specifications and performances in temperature, channel 1 + 2 SPRTs / PRTs: Measurement Type At 0°C: 4 mK Over full range: 7 mK At 0°C: 4 mK Over full range: 7 mK Temperature conversions: IEC 60751 (2008), Callendar-van Dusen, ITS-90 Measuring current: 1 mA and 1.428 mA at ±0.4% reversing Keep-warm current: 1 mA and 1.428 mA Thermistors: Measurement Type Measuring current: 5 µA reversing Thermocouples: Measurement Type Specifications and performances in process, channel 3 50-52 Avenue Paul Langevin, F-91130 Ris Orangis - Tél. : 01 69 02 88 88 - Fax : 01 69 02 04 38
Open the catalog to page 4Current: Measurement Range Further features Statistical functions In addition to instantaneous display, the user can select mean of 2-100 measurements with standard deviation Measurement time General specifications Size Graphical color back-lit LCD display, 230 x 420 Display unit: °C, °F, K, Ω, mV, mA Power supply Communication ports Serial interface, Ethernet, USB Storage capacity > 180 days of measurements stored with date and time on internal memory Environmental specifications Reference range Operating reference range
Open the catalog to page 5Models and accessories Instrument: MilliK 924 3-channel expandable precision thermometer for PRTs, thermocouples, thermistors and 4-20 mA transmitters, -270°C to 1820°C Delivered in standard with: Cal Notepad software Serial communication cable User manual Traceable certificate External channel expander: 914a MillisKanner channel expander (first unit) Delivered in standard with: Connection cable for MilliK 932-42-33 units Universal power supply 90 / 240 V (50/60 Hz), to power up to 4 MillisKanner Digital connection cable Additional connection cable MilliK / MillisKanner Scanner MillisKanner (référence...
Open the catalog to page 6Semi standard Pt100 (-50°C to 250°C), with LEMO connector and carrying Semi standard Pt100 (-50°C to 670°C), with LEMO connector and carrying Semi standard Pt100 (-80°C to 670°C), with LEMO connector and carrying Semi standard Pt100 (-200°C to 165°C), with LEMO connector and carrying Semi standard PRT: 909L/100/480/TTI Semi standard Pt100 in metal (-200°C to 165°C), length: 480 mm, with LEMO connector and carrying case 909Q/100/480/TTI Semi standard Pt100 in quartz (-200°C to 550°C), length: 480 mm, with LEMO connector and carrying case Terminal adapter Soft carrying case Packing information:...
Open the catalog to page 75 Pages
10 Pages
10 Pages
6 Pages
5 Pages
10 Pages
5 Pages
6 Pages
7 Pages
7 Pages
5 Pages
7 Pages
6 Pages
6 Pages
12 Pages
6 Pages
6 Pages
5 Pages
6 Pages
6 Pages
6 Pages
6 Pages
5 Pages
8 Pages
10 Pages
7 Pages
9 Pages
7 Pages
10 Pages
12 Pages
5 Pages
6 Pages
8 Pages
7 Pages
4 Pages
11 Pages
12 Pages
5 Pages
8 Pages
4 Pages
11 Pages
6 Pages
8 Pages
4 Pages
10 Pages
12 Pages
4 Pages
2 Pages
6 Pages