![AOIP - logo](https://img.directindustry.com/images_di/logo-p/L7451.gif)
Group: ASGARD
Catalog excerpts
![ISOPALM 200 - 1](https://img.directindustry.com/pdf/repository_di/7451/isopalm-200-524053_1m.jpg)
ISOPALM 200 Cable fault locator The fault locator ISOPALM 200 is designed to identify and locate with high precision any faults on telecom cables: insulation faults (bare, blasted, buried wires) and break on wires (partial or total break). Display of fault location in meters Suitable for Pupin coils Homogeneous and heterogeneous cables
Open the catalog to page 1![ISOPALM 200 - 2](https://img.directindustry.com/pdf/repository_di/7451/isopalm-200-524053_2m.jpg)
Description The fault locator ISOPALM 200 is designed to identify and locate with high precision any faults on telecom cables: insulation faults (bare, blasted, buried wires) and breaks on wires (partial or total break). Display of fault location in meters Suitable for Pupin coils Homogeneous and heterogeneous cables ISOPALM 200 also has the ability to make loop resistance measurements, insulation resistance measurements and resistance ratio measurements ΔR. It uses standard impedance / impedance ratio measurement methods, and brings, due to innovative technology, key advantages to the user...
Open the catalog to page 2![ISOPALM 200 - 3](https://img.directindustry.com/pdf/repository_di/7451/isopalm-200-524053_3m.jpg)
When wires of a same pair are of different types, ISOPALM 200 can use a third cable to calculate the distance to a fault. Display of fault position in meters After programming in the instrument of the parameters of every section of the cable under test (length, linear resistance, eventually temperature and pupins), the ISOPALM 200 displays the distance to the fault in meters with a resolution of 0.1 to 1 m according to the cable length. The distance is calculated either from the cable length or from the loop resistance. For more accuracy in the location of the fault, both results can be...
Open the catalog to page 3![ISOPALM 200 - 4](https://img.directindustry.com/pdf/repository_di/7451/isopalm-200-524053_4m.jpg)
Specifications Measurement of AC / DC voltage Range Resistance measurement Range Isolation measurement at test voltage 50 to 100 V Range Isolation measurement at test voltage 150 to 300 V Range From 0 to 999 kΩ: 2 digits after coma From 1 MΩ to 9.99 MΩ: 2 digits after coma From 10 MΩ to 99.9 MΩ: 1 digit after coma From 100 MΩ to 5 GΩ: 0 digit after coma Isolation measurement at test voltage 350 to 500 V Range From 0 to 999 kΩ: 2 digits after coma From 1 MΩ to 9.99 MΩ: 2 digits after coma From 10 MΩ to 99.9 MΩ: 1 digit after coma
Open the catalog to page 4![ISOPALM 200 - 5](https://img.directindustry.com/pdf/repository_di/7451/isopalm-200-524053_5m.jpg)
From 100 MΩ to 10 GΩ: 0 digit after coma Capacitance measurement Range Fault location Type Fault between 2 wires on the same pair Fault between 2 wires on different pairs Fault between 1 wire and the ground Fault location methods integrated into the instrument Method Location of broken wire: With measurement of loop resistance, if Rab > 10 000 Ω, the wire is broken Test on homogeneous cables Location of insulation fault: If Ihealthy > 1000, Iunhealthy (ou Ib > 1000 Ia) Test on homogeneous and heterogeneous cables Fabe / Küpfmüller Location of insulation fault: If Ihealthy/ Iunhealthy > 2 x...
Open the catalog to page 5![ISOPALM 200 - 6](https://img.directindustry.com/pdf/repository_di/7451/isopalm-200-524053_6m.jpg)
Environmental specifications Reference range Operating reference range Limit operating range Storage temperature limits Maximum height Safety specifications Class In accordance with EN 61010-1 Category II, pollution 2
Open the catalog to page 6![ISOPALM 200 - 7](https://img.directindustry.com/pdf/repository_di/7451/isopalm-200-524053_7m.jpg)
Models and accessories Instrument: ISOPALM 200 Cable fault locator Delivered in standard with: Remote looping device Set of testing leads and crocodile clips User manual Transport case, shoulder strap and stand Packing information: Size
Open the catalog to page 7All AOIP catalogs and technical brochures
-
DRAGO 934
5 Pages
-
CALYS 1200
10 Pages
-
CALYS 1000
10 Pages
-
RAYOMATIC 16
7 Pages
-
RLV
5 Pages
-
EPM
10 Pages
-
UNIGAS 3000
7 Pages
-
RN 5306
5 Pages
-
LKS 1000 Leakshooter camera
6 Pages
-
TTI 10
6 Pages
-
RN 5360
5 Pages
-
MEGOHM 200
7 Pages
-
MF 28
6 Pages
-
IND 45
6 Pages
-
CALYS 1500
12 Pages
-
RAYOMATIC USB 2.2
6 Pages
-
RAYOMATIC PE
6 Pages
-
IRTEC P IVT
5 Pages
-
RAYOMATIC 16 2.2
6 Pages
-
RAYOMATIC NET
6 Pages
-
RAYOMATIC TC
6 Pages
-
ICO 51
6 Pages
-
LKS 1000
5 Pages
-
MILLIK
7 Pages
-
TM 6602 / 6612 / 6630
8 Pages
-
TC 6621 / 6622
10 Pages
-
SN 8310
7 Pages
-
CALYS 60 IS
9 Pages
-
CP 6632
7 Pages
-
THERMYS 150
10 Pages
-
CALYS 120 IS
12 Pages
-
ZX
5 Pages
-
OM 10
6 Pages
-
OM 21
8 Pages
-
CRIT 100
4 Pages
-
IRtec P
11 Pages
-
FD 5 / 10 / 15
12 Pages
-
VNE20
5 Pages
-
OM 16
8 Pages
-
SATURN CYCLOP 878
4 Pages
-
CALYS 80 IS
11 Pages
-
CALYS 80P
10 Pages
-
P200 PRO
8 Pages
-
CALYS 150
8 Pages
-
motor starter
4 Pages
-
Frontdaq 10 isolated channels
4 Pages
-
Data Acquisition Systems DATALOG
12 Pages
-
Accuracy Thermometer PHP 602
2 Pages
Archived catalogs
-
2016 RAYOMATIC USB
6 Pages