ISOPALM 200
7Pages

{{requestButtons}}

Catalog excerpts

ISOPALM 200 - 1

ISOPALM 200 Cable fault locator The fault locator ISOPALM 200 is designed to identify and locate with high precision any faults on telecom cables: insulation faults (bare, blasted, buried wires) and break on wires (partial or total break). Display of fault location in meters Suitable for Pupin coils Homogeneous and heterogeneous cables

Open the catalog to page 1
ISOPALM 200 - 2

Description The fault locator ISOPALM 200 is designed to identify and locate with high precision any faults on telecom cables: insulation faults (bare, blasted, buried wires) and breaks on wires (partial or total break). Display of fault location in meters Suitable for Pupin coils Homogeneous and heterogeneous cables ISOPALM 200 also has the ability to make loop resistance measurements, insulation resistance measurements and resistance ratio measurements ΔR. It uses standard impedance / impedance ratio measurement methods, and brings, due to innovative technology, key advantages to the user...

Open the catalog to page 2
ISOPALM 200 - 3

When wires of a same pair are of different types, ISOPALM 200 can use a third cable to calculate the distance to a fault. Display of fault position in meters After programming in the instrument of the parameters of every section of the cable under test (length, linear resistance, eventually temperature and pupins), the ISOPALM 200 displays the distance to the fault in meters with a resolution of 0.1 to 1 m according to the cable length. The distance is calculated either from the cable length or from the loop resistance. For more accuracy in the location of the fault, both results can be...

Open the catalog to page 3
ISOPALM 200 - 4

Specifications Measurement of AC / DC voltage Range Resistance measurement Range Isolation measurement at test voltage 50 to 100 V Range Isolation measurement at test voltage 150 to 300 V Range From 0 to 999 kΩ: 2 digits after coma From 1 MΩ to 9.99 MΩ: 2 digits after coma From 10 MΩ to 99.9 MΩ: 1 digit after coma From 100 MΩ to 5 GΩ: 0 digit after coma Isolation measurement at test voltage 350 to 500 V Range From 0 to 999 kΩ: 2 digits after coma From 1 MΩ to 9.99 MΩ: 2 digits after coma From 10 MΩ to 99.9 MΩ: 1 digit after coma

Open the catalog to page 4
ISOPALM 200 - 5

From 100 MΩ to 10 GΩ: 0 digit after coma Capacitance measurement Range Fault location Type Fault between 2 wires on the same pair Fault between 2 wires on different pairs Fault between 1 wire and the ground Fault location methods integrated into the instrument Method Location of broken wire: With measurement of loop resistance, if Rab > 10 000 Ω, the wire is broken Test on homogeneous cables Location of insulation fault: If Ihealthy > 1000, Iunhealthy (ou Ib > 1000 Ia) Test on homogeneous and heterogeneous cables Fabe / Küpfmüller Location of insulation fault: If Ihealthy/ Iunhealthy > 2 x...

Open the catalog to page 5
ISOPALM 200 - 6

Environmental specifications Reference range Operating reference range Limit operating range Storage temperature limits Maximum height Safety specifications Class In accordance with EN 61010-1 Category II, pollution 2

Open the catalog to page 6
ISOPALM 200 - 7

Models and accessories Instrument: ISOPALM 200 Cable fault locator Delivered in standard with: Remote looping device Set of testing leads and crocodile clips User manual Transport case, shoulder strap and stand Packing information: Size

Open the catalog to page 7

All AOIP catalogs and technical brochures

  1. RAYOMATIC 16

    7 Pages

  2. RLV

    5 Pages

  3. EPM

    10 Pages

  4. UNIGAS 3000

    7 Pages

  5. RN 5306

    5 Pages

  6. TTI 10

    6 Pages

  7. RN 5360

    5 Pages

  8. MEGOHM 200

    7 Pages

  9. MF 28

    6 Pages

  10. CALYS 1000

    7 Pages

  11. IND 45

    6 Pages

  12. CALYS 1500

    12 Pages

  13. RAYOMATIC PE

    6 Pages

  14. IRTEC P IVT

    5 Pages

  15. RAYOMATIC TC

    6 Pages

  16. ICO 51

    6 Pages

  17. LKS 1000

    5 Pages

  18. MILLIK

    7 Pages

  19. TC 6621 / 6622

    10 Pages

  20. SN 8310

    7 Pages

  21. CALYS 60 IS

    9 Pages

  22. CP 6632

    7 Pages

  23. THERMYS 150

    10 Pages

  24. CALYS 120 IS

    12 Pages

  25. ZX

    5 Pages

  26. OM 10

    6 Pages

  27. OM 21

    8 Pages

  28. CRIT 100

    4 Pages

  29. IRtec P

    11 Pages

  30. FD 5 / 10 / 15

    12 Pages

  31. VNE20

    5 Pages

  32. OM 16

    8 Pages

  33. CALYS 80 IS

    11 Pages

  34. CALYS 80P

    10 Pages

  35. P200 PRO

    8 Pages

  36. CALYS 150

    8 Pages