Group: ASGARD
Catalog excerpts
FD 5 / 10 / 15, fast acquisition modules with universal synchronized inputs and embedded webserver software FD systems are a series of fast (470 Hz/channel) and flexible data acquisition modules available in 3 models of 5 / 10 / 15 universal synchronized inputs.
Open the catalog to page 1Description FD systems are a series of fast (470 Hz / channel) and flexible data acquisition modules to be used in the field and on test benches. 3 different models are available with 5, 10 or 15 universal synchronized inputs (1 ADC per channel). All necessary configuration and management software (WEB server technology) are embedded into the plug-and-play system and allow remote control of the acquisition through any web browser: Setup, start, result display, monitoring and data exportation. FD memory capacity (internal and external via USB drive or SD card), allows several months of data...
Open the catalog to page 2Specifications Specifications and performances in temperature @23°C ±5°C Uncertainty is given in % of reading + fixed value. Resistive probes: Measurement Type High accuracy / 1 year (periodic mode) Standard accuracy / 1 year (periodic mode) Low accuracy / 1 year (continuous mode) High accuracy / 1 year Standard accuracy / 1 year Low accuracy / 1 year (continuous Thermocouples: Measurement Type
Open the catalog to page 3(periodic mode) (periodic mode)
Open the catalog to page 4Accuracy is given for reference @ 0°C. When using the internal reference junction (except couple B), add an additional uncertainty at 0°C of ±0.5 °C in high or standard accuracy and ±0.8°C in low accuracy. Temperature coefficient: < 5% of accuracy /°C It is possible (thermocouple B excepted) to choose by programming the cold junction localization: - External at 0°C - Internal (temperature compensation of instrument’s terminals) - Manually entered - External (measurement at an input channel)
Open the catalog to page 5Specifications and performances in process @23°C ±5°C DC voltage: Measurement Range Measuring range High accuracy / 1 year (periodic mode) Standard Low accuracy / 1 accuracy / 1 year year (periodic mode) (continuous mode) Input impedance: 10 MΩ for ranges up to 1 V 1 MΩ for ranges up to 100 V Temperature coefficient: < 7 ppm/°C beyond reference domain for 100 mV and 1 V ranges < 15 ppm/°C beyond reference domain for 10 V, 50 V and 100 V ranges) DC current: Measurement With or without loop supply Range Measuring range High accuracy / 1 year (periodic mode) Standard Low accuracy / 1 accuracy...
Open the catalog to page 6Uncertainties given for 4-wire measurement Automatic detection of connection scheme: 2 wires, 3 wires, or 4 wires. In 2-wire connection, measurement includes line resistances. In 3-wire connection, add the line resistance imbalance 200 kΩ range: short or shielded wires Temperature coefficient: < 20 ppm/°C beyond reference domain Frequency, pulse: Measurement Type Temperature coefficient: < 5 ppm/°C beyond reference domain Trigger level: 1 V Shots/min and Hz scale Measurement on frequency output and dry contacts Specifications and performances in process @23°C ±5°C Analogue output Range...
Open the catalog to page 7Calculation channels The embedded software is able to perform data calculations and store calculation results. Calculations can come from input channel values or conditional calculations (Data processing, statistics, conditioning, Boolean calculations). Calculation channels can be used to condition outputs (relays, analogue outputs). Every channel can be configured with 4 alarms levels for monitoring purposes. Alarms events are stored in a dedicated file (alarm file). Only allowed users can access to the file. Every channel can be scaled for sensor correction or application of a special...
Open the catalog to page 8Storage capacity Internal of 100,000 values External on USB drive External on SD card Environmental specifications Reference range Operating reference range Storage temperature limits Maximum height
Open the catalog to page 9FD5-5 5-channel stand-alone acquisition system Delivered in standard with: • User manual • Power adapter • Crossed Ethernet cable and USB cable • 5 x 4-contact female terminal blocks • 1 x 6-contact female terminal block • Installation CD with drivers and utilities • Factory test report FD5-10 10-channel stand-alone acquisition system Delivered in standard with: • User manual • Power adapter • Crossed Ethernet cable and USB cable • 10 x 4-contact female terminal blocks • 1 x 6-contact female terminal block • Installation CD with drivers and utilities • Factory test report FD5-15 15-channel...
Open the catalog to page 10Carrying case WIFI access point 3G / GPRS router, Ethernet / RS 485-232 secure by VPN H90 quad-band magnetic antenna, cable length: 1500 mm Software: VISULOGTM Monitoring & data processing software light version – 1 licence VISULOGTM-ETAL Monitoring & data processing software light version – 1 licence + Calibration module VISULOGTM-PHARMA Monitoring & data processing software light version – 1 licence + Module for advanced management of access rights, 21 CFR Part 11 compliant VISULOGTM-ETAL-PHARMA Monitoring & data processing software light version – 1 licence + Calibration module + Module...
Open the catalog to page 11All AOIP catalogs and technical brochures
-
DRAGO 934
5 Pages
-
CALYS 1200
10 Pages
-
CALYS 1000
10 Pages
-
RAYOMATIC 16
7 Pages
-
RLV
5 Pages
-
EPM
10 Pages
-
UNIGAS 3000
7 Pages
-
RN 5306
5 Pages
-
LKS 1000 Leakshooter camera
6 Pages
-
TTI 10
6 Pages
-
RN 5360
5 Pages
-
MEGOHM 200
7 Pages
-
MF 28
6 Pages
-
IND 45
6 Pages
-
CALYS 1500
12 Pages
-
RAYOMATIC USB 2.2
6 Pages
-
RAYOMATIC PE
6 Pages
-
IRTEC P IVT
5 Pages
-
RAYOMATIC 16 2.2
6 Pages
-
RAYOMATIC NET
6 Pages
-
RAYOMATIC TC
6 Pages
-
ICO 51
6 Pages
-
LKS 1000
5 Pages
-
MILLIK
7 Pages
-
TM 6602 / 6612 / 6630
8 Pages
-
TC 6621 / 6622
10 Pages
-
SN 8310
7 Pages
-
CALYS 60 IS
9 Pages
-
CP 6632
7 Pages
-
THERMYS 150
10 Pages
-
CALYS 120 IS
12 Pages
-
ZX
5 Pages
-
OM 10
6 Pages
-
OM 21
8 Pages
-
ISOPALM 200
7 Pages
-
CRIT 100
4 Pages
-
IRtec P
11 Pages
-
VNE20
5 Pages
-
OM 16
8 Pages
-
SATURN CYCLOP 878
4 Pages
-
CALYS 80 IS
11 Pages
-
CALYS 80P
10 Pages
-
P200 PRO
8 Pages
-
CALYS 150
8 Pages
-
motor starter
4 Pages
-
Frontdaq 10 isolated channels
4 Pages
-
Data Acquisition Systems DATALOG
12 Pages
-
Accuracy Thermometer PHP 602
2 Pages
Archived catalogs
-
2016 RAYOMATIC USB
6 Pages