1. Catalogs
  2. AOIP
  3. CALYS 80P

CALYS 80P

CALYS 80P
1 / 10 PagesView full catalog

CALYS 80P

Product catalog summary
Description
CALYS 80P is a high-accuracy field pressure calibrator with an accuracy of 0.01%. It is designed for advanced process maintenance and is suitable for both field and lab measurements. The device supports simultaneous measurement and generation over two isolated channels for pressure and process signals, and can also measure resistance signals and resistive probes. It offers extended functionalities such as temperature simulation, scaling, steps, synthesizer, and statistical functions, enhancing data exploitation and traceability. The device can store up to 10 instrument configurations and over 1,500 measurements with date and time.

Pressure Calibration
CALYS 80P can be configured with single or dual range internal pressure modules for gauge, absolute, and differential pressure measurements. External interchangeable pressure modules extend the range up to 700 bar. The device is user-friendly, allowing quick calibration tasks across the process chain. It can store 10 calibration procedures and upload data to a computer for customized calibration certificates using DATACAL software.

Key Features
- Switch test, leak test
- Dual channel display for simultaneous indication of measured and simulated values
- Graphic mode for trend display

Specifications
Temperature
- Uncertainty: % of reading + fixed value
- Range: -200°C to +850°C for various Pt and Cu sensors
- Accuracy: 0.01% RDG + specific fixed value

Pressure
- Media: AISI 316 SS compatible fluids
- Temperature compensation: Automatic
- Accuracy: ±0.025% F.S.
- Overpressure: 125% F.S.

Process
- DC Voltage and Current: Measurement and simulation with specified ranges and accuracies
- Resistance: Measurement with specified ranges and accuracies

Further Features
- Scaling, statistical functions, transmitter tests, switch and leak tests
- Transmitter function for converting input signals to 4-20 mA output

General Specifications
- Size: 290 x 98 x 57 mm
- Weight: Nett 1.4 kg, Gross 2.5 kg
- Display: 240 x 320 pixel LCD
- Power supply: 100 – 120 - 230 VAC, 50/60 Hz
- Battery: Rechargeable Ni-Mh
- Communication: RS 232, full bidirectional TTL
- Storage: > 1,500 measured values

Environmental Specifications
- Operating range: -10 to 55°C
- Storage temperature: 0°C to +60°C
- IP protection: IP54

Safety Specifications
- Protections: Thermal fuse, high voltage suppressor, resistor-diode voltage limiter
- Class: II 1G Ex ia IIC T4

Models and Accessories
- Internal and external pressure sensors with various ranges
- External hand pumps and further accessories
- Calibration software DATACAL MC
- Certification: COFRAC certificate of calibration

Packing Information
- Size: 290 mm x 98 mm x 57 mm
- Weight: Nett 1.4 kg, Gross 2.5 kg
See more

Catalog excerpts

CALYS 80P-1

CALYS 80P, field pressure calibrator with high accuracy 0.01% CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%.

 Open the catalog to page 1
CALYS 80P-2

Description CALYS 80P is a field pressure calibrator within CALYS range with high accuracy of 0.01%. CALYS are the perfect tools for advanced process maintenance and use on test bench in nonhazardous areas. Suitable for all field and lab measurements, CALYS 80P is dedicated to simultaneous measurement and generation over two isolated channels of pressure and process signals. It can also measure resistance signals and resistive probes. Providing extended functionalities (temperature simulation, scaling, steps, synthesizer, statistical functions…) and audit trails, CALYS series makes advanced data...

 Open the catalog to page 2
CALYS 80P-3

Specifications Specifications and performances in temperature @23°C ±5°C Uncertainty is given in % of reading (CALYS 80P display) + fixed value. Resistive probes: Measurement and simulation Sensor Range (Input and Output) Connections: 2, 3 and 4 wires Rtd measurement excitation current: 0.2 mA Rtd cable compensation: up to 100 mΩ (for each wire) Rtd cable compensation error (Pt100): ±0.005°C/ of total wire Maximum load resistance: 600 Ω @ 20 mA Specifications and performances in pressure @23°C ±5°C Pressure Pressure media: AISI 316 SS compatible fluids (water, gas, and oil) Temperature compensation:...

 Open the catalog to page 3
CALYS 80P-4

Measurement by internal pressure module Reference Accuracy: ±0.025% F.S. Overpressure: 125% F.S. Port: female, 1/8" BSP Measurement by external pressure module Reference Accuracy: ±0.025% F.S. Overpressure: 125% F.S. Port: male, 1/4" BSP Connection wire length: 2 m Specifications and performances in process @23°C ±5°C DC voltage: Measurement and simulation 50-52 Avenue Paul Langevin, F-91130 Ris Orangis - Tél. : 01 69 02 88 88 - Fax : 01 69 02 04 38

 Open the catalog to page 4
CALYS 80P-5

Input impedance: < 10 MΩ for ranges up to 2 V > 500 kΩ for ranges up to 29 V Output impedance (emf output): < 0.5 Ω with a maximum current of 0.5 mA Output noise (at 300 Hz): < 2 μV pp for ranges up to 200 mV < 10 μV pp for ranges up to 2 V < 80 μV pp for ranges up to 20 V DC current: Measurement and simulation With or without loop supply Type Input impedance: < 20 Ω at 1 mA Emission limited to 21 mA max on passive current loop Loop supply: 24 V ±5% Resistance: Measurement Range Connections: 2, 3 and 4 wires Measurement excitation current: 0.2 mA Maximum load resistance: 1000 Ω @ 20 mA Further...

 Open the catalog to page 5
CALYS 80P-6

Statistical functions hold, max, min, offset, zero, average Transmitters tests The feature enables any pressure or temperature transmitter to be controlled and calibrated with simultaneous display of input and output values in % F.S. or in actual unit. The measuring circuit is also able to power the loop for a direct connection to the transmitter under test. Transmitter function CALYS 80P can be used as a transmitter. Any input signal (electric or pressure) can be converted into a 4-20 mA output. The galvanic insulation between the input and output channels allows this function to be used on...

 Open the catalog to page 6
CALYS 80P-7

Environmental specifications Reference range Operating reference range Storage temperature limits Maximum height Safety specifications Protections Thermal fuse High voltage suppressor Resistor-diode voltage limiter class II 1G Ex ia IIC T4 (-20°C from T Ambient to +50°C)

 Open the catalog to page 7
CALYS 80P-8

Models and accessories Instrument: CALYS80P On-site documenting pressure calibrator with high accuracy 0.01% Delivered in standard with: Internal pressure module to select from the list below Battery charger Protection rubber holster Factory test report Internal pressure sensors - AISI316SS - ± 0.025% FS: (2 maximum) IPM000100G -100 / 100 mbar (gauge) - Res. 0.001 mbar -500 / 500 mbar (gauge) - Res. 0.01 mbar External pressure sensors - AISI316SS - ± 0.025% FS: EPM000100G -100 / 100 mbar (gauge) - Res. 0.001 mbar -500 / 500 mbar (gauge) - Res. 0.01 mbar

 Open the catalog to page 8
CALYS 80P-9

External hand pump: F3280013 From -0.8 to 2 bar pressure pump From -0.95 to 40 bar pressure pump From 0 to 350 bar oil / water pump External 700 bar oil / water pump External 700 bar oil / water pump with high pressure hose External 1000 bar oil/water pump with high pressure hose 700 bar oil/water compact bench Electrical signal test leads Vinyl carrying case with accessories folder MiniDin Connectors Kit Tc J, K, T, S Female connector MiniDin Connectors Kit Tc J, K, T, S Male connector Calibration software for CALYS 60 IS / 80 IS / 120 IS / 80P / 80P IS Supplied with USB cable COFRAC certificate...

 Open the catalog to page 9
CALYS 80P-10

With all relevant data points where the device has been tested Packing information: Size Weight (nett) Weight (gross)

 Open the catalog to page 10
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.