CALYS 60 IS
9Pages

{{requestButtons}}

Catalog excerpts

CALYS 60 IS - 1

ATEX field documenting calibrator with accuracy 0.02% CALYS 60 IS is an ATEX documenting multifunction calibrator within CALYS IS range.

Open the catalog to page 1
CALYS 60 IS - 2

Description CALYS 80 IS is an ATEX documenting multifunction calibrator within CALYS IS range. It is the perfect tool for advanced process maintenance and use on test bench in hazardous and nonhazardous areas. Suitable for all field and lab measurements, it can simultaneously measure and generate over two isolated channels various signals of temperature, resistance, process, pressure and frequency in one single instrument. Providing extended functionalities (temperature simulation, scaling, steps, synthesizer, statistical functions…) and audit trails, CALYS IS series complies with both 21...

Open the catalog to page 2
CALYS 60 IS - 3

Specifications Specifications and performances in temperature @23°C ±5°C Uncertainty is given in % of reading (CALYS 60 IS display) + fixed value. Resistive probes: Measurement and simulation Sensor Range (Input and Output) Connections: 2, 3 and 4 wires Rtd simulation excitation current: from 0.1 to 4 mA without incremental error Rtd measurement excitation current: 0.2 mA Rtd cable compensation: up to 100 m (for each wire) Rtd cable compensation error (Pt100): ± 0.005°C/ of total wire Maximum load resistance: 600 Ω @ 20 mA Thermocouples: Measurement and simulation Type

Open the catalog to page 3
CALYS 60 IS - 4

Display units: °C, °F et K Resolution: 0.01°C / 0.01°F Temperature scale: ITS90 and IPTS68 Reference junction compensation: internal automatic from -10°C to +55°C or external Rj compensation drift: ± 0.002°C/°C (from -10 °C to +45 °C) - Class A Pt100 Input impedance: > 10 MΩ Specifications and performances in pressure @23°C ±5°C Pressure Pressure media: AISI 316 SS compatible fluids (water, gas, and oil) Temperature compensation: Automatic with built-in calibration matrix Engineering units: mbar, bar, hPa, kPa, Mpa, kg/cm2, kg/m2, psi, mmH2O, cmH2O, mH2O, Torr, atm, lb/ft2, inH2O, FTH2O,...

Open the catalog to page 4
CALYS 60 IS - 5

Accuracy: ± 0.025% F.S. Overpressure: 125% F.S. Port: male, 1/4" BSP Connection wire length: 2 m Specifications and performances in process @23°C ±5°C DC voltage: Measurement and simulation Range Input impedance: < 10 MΩ for ranges up to 2 V > 500 kΩ for ranges up to 20 V Output impedance (emf output): < 0.5 Ω with a maximum current of 0.5 mA Output noise (at 300 Hz): < 2 μV pp for ranges up to 200 mV < 10 μV pp for ranges up to 2 V < 80 μV pp for ranges up to 20 V DC current: Measurement and simulation With or without loop supply Range Input impedance: < 20 Ω at 1 mA Maximum load...

Open the catalog to page 5
CALYS 60 IS - 6

Source resistance effects: ± 1 μV error for 1000 Ω source resistance Simulation excitation current: from 0.1 to 4 mA without incremental error Measurement excitation current: 0.2 mA Maximum load resistance: 600 Ω @ 20 mA Frequency, pulse: Measurement and simulation Type Further features Scaling in measurement and simulation modes Setup of zero and span programmable within -399999 and +999999 Scaling allows process signals to be displayed in % of FS or in all other units. This function also allows sensors to be corrected after a calibration. Square root In combination with scaling function...

Open the catalog to page 6
CALYS 60 IS - 7

Switch test Temperature, signal and pressure switches can be tested using this advanced procedure. The calibrator will hold the display reading when the contact changes status. General specifications Size 240 x 320 pixel liquid crystal graphical display with backlite and contrast control Display of result as table of values or trend curve Power supply Type: NiMh Charging time: 8 h, 6 h if instrument switched off Life time: 8 h (Tc and V), 3 h at 20 mA Communication ports Storage capacity 10 data with manual or automatic recall Environmental specifications Reference range Operating reference...

Open the catalog to page 7
CALYS 60 IS - 8

Models and accessories Instrument: CALYS60 IS On-site ATEX documenting multifunction calibrator with accuracy 0.02% Delivered in standard with: User manual Battery charger Protection rubber holster Factory test report External pressure sensors - AISI316SS - ± 0.025% FS: EPM000100G -100 / 100 mbar (gauge) - Res. 0.001 mbar -500 / 500 mbar (gauge) - Res. 0.01 mbar External hand pump: F3280013 From -0.8 to 2 bar pressure pump From -0.95 to 40 bar pressure pump From 0 to 350 bar oil / water pump External 700 bar oil / water pump External 700 bar oil / water pump with high pressure hose

Open the catalog to page 8
CALYS 60 IS - 9

External 1000 bar oil/water pump with high pressure hose 700 bar oil/water compact bench Electrical signal test leads Vinyl carrying case with accessories folder MiniDin Connectors Kit Tc J, K, T, S Female connector MiniDin Connectors Kit Tc J, K, T, S Male connector Software: DATACAL Calibration software for CALYS 75 / 100 / 150 Supplied with USB cable COFRAC certificate of calibration With all relevant data points where the device has been tested Packing information: Size Weight without packing 1.4 g

Open the catalog to page 9

All AOIP catalogs and technical brochures

  1. RAYOMATIC 16

    7 Pages

  2. RLV

    5 Pages

  3. EPM

    10 Pages

  4. UNIGAS 3000

    7 Pages

  5. RN 5306

    5 Pages

  6. TTI 10

    6 Pages

  7. RN 5360

    5 Pages

  8. MEGOHM 200

    7 Pages

  9. MF 28

    6 Pages

  10. CALYS 1000

    7 Pages

  11. IND 45

    6 Pages

  12. CALYS 1500

    12 Pages

  13. RAYOMATIC PE

    6 Pages

  14. IRTEC P IVT

    5 Pages

  15. RAYOMATIC TC

    6 Pages

  16. ICO 51

    6 Pages

  17. LKS 1000

    5 Pages

  18. MILLIK

    7 Pages

  19. TC 6621 / 6622

    10 Pages

  20. SN 8310

    7 Pages

  21. CP 6632

    7 Pages

  22. THERMYS 150

    10 Pages

  23. CALYS 120 IS

    12 Pages

  24. ZX

    5 Pages

  25. OM 10

    6 Pages

  26. OM 21

    8 Pages

  27. ISOPALM 200

    7 Pages

  28. CRIT 100

    4 Pages

  29. IRtec P

    11 Pages

  30. FD 5 / 10 / 15

    12 Pages

  31. VNE20

    5 Pages

  32. OM 16

    8 Pages

  33. CALYS 80 IS

    11 Pages

  34. CALYS 80P

    10 Pages

  35. P200 PRO

    8 Pages

  36. CALYS 150

    8 Pages