CALYS 1500 Advanced laboratory electrical calibrator / Dual input thermometer
Open the catalog to page 1CALYS 1500, most advanced and accurate laboratory electrical calibrator of the range, does not only work as a simulator (IN / OUT) but also as a dual channel thermometer (IN / IN) to perform comparison calibration. It calibrates HART transmitters (HART communicator) and thermistors. Description CALYS 1500, most advanced and accurate laboratory electrical calibrator of the range, does not only work as a simulator (IN / OUT) but also as a dual channel thermometer (IN / IN) to perform comparison calibration. It calibrates HART transmitters (HART communicator) and thermistors. It is the perfect...
Open the catalog to page 2Innovative and ergonomic design • Metal housing for enhanced robustness • Capacitive touch panel • USB communication • Carrying handle • Battery and main powered Graphic screen and display resolution CALYS 1500 allows the digit number after the dot to be selected: This function is justified by the needs of users who want or not to display the best resolution for calibration or on the contrary limit it for simple verifications. CALYS 1500 dual display indicates permanently the measurement value, and also the emitted value, the gauge and the used functions. On the top date, time and also...
Open the catalog to page 3Specifications Specifications and performances in temperature @23°C ±5°C Uncertainty is given in % of reading (CALYS 1500 display) + fixed value. Temperature coefficient: < 10% of accuracy /°C beyond reference domain Resistive probes measurements in 2, 3 or 4 wires: automatic recognition of number of connected wires, with indication on screen Accuracies are given for 4-wire mounted probes Take into account particular error of temperature sensor used and implementation conditions Admissible measuring current: 0.25 mA (Measurement) or 0.1 mA to 1 mA (Emission) 50-52 Avenue Paul Langevin,...
Open the catalog to page 4Thermocouples: Measurement and simulation Type
Open the catalog to page 5Temperature coefficient: < 5% of accuracy /°C beyond reference domain Accuracy is given for reference @ 0°C. When using the internal reference junction (except couple B) add an additional uncertainty of 0.2 °C at 0 °C. It is possible (thermocouple B excepted) to choose by programming the cold junction localization: External at 0°C, internal (temperature compensation of instrument's terminals) or manually entered. Display unit: °C? F and K. Thermocouples: G, D: For specifications, refer to the instruction manual (Available on request) Pressure: Measurement by external digital sensor 50-52...
Open the catalog to page 6mV Temperature coefficient: < 5% of accuracy /°C beyond reference domain
Open the catalog to page 8Temperature coefficient: < 5 ppm/°C beyond reference domain lext : Current received by the calibrator File Menu Users can save up to 10 full configurations of the instruments and recall them. Configurations include all programming done on instrument. Scaling in measurement and simulation modes Scaling allows process signals to be displayed in % of FS or in all other units. This function also allows sensors to be corrected after a calibration. Relative measurement
Open the catalog to page 10Models and accessories Instrument: CALYS 1500 Benchtop precision documenting multifunction calibrator Delivered in standard with: • Quick start manual • Battery charger • Set of 6 testing leads • Factory test report Accessories: ACL433 External digital pressure sensor, range to be specified at the order: Absolute or relative pressure: Range from -1 -> 1; 3; 10; 30 bar Absolute pressure: Range from -1 -> 100; 300; 1000 bar ACL9311 Set of 6 measuring cables with removable crocodile clips ACL500 Hart modem for CALYS 150 ACL600 Cable to drive temperature dry blocks and baths for...
Open the catalog to page 11All AOIP catalogs and technical brochures
-
RAYOMATIC 16
7 Pages
-
RLV
5 Pages
-
EPM
10 Pages
-
UNIGAS 3000
7 Pages
-
RN 5306
5 Pages
-
LKS 1000 Leakshooter camera
6 Pages
-
TTI 10
6 Pages
-
RN 5360
5 Pages
-
MEGOHM 200
7 Pages
-
MF 28
6 Pages
-
CALYS 1000
7 Pages
-
IND 45
6 Pages
-
RAYOMATIC USB 2.2
6 Pages
-
RAYOMATIC PE
6 Pages
-
RAYOMATIC USB
6 Pages
-
IRTEC P IVT
5 Pages
-
RAYOMATIC 16 2.2
6 Pages
-
RAYOMATIC NET
6 Pages
-
RAYOMATIC TC
6 Pages
-
ICO 51
6 Pages
-
LKS 1000
5 Pages
-
MILLIK
7 Pages
-
TM 6602 / 6612 / 6630
8 Pages
-
TC 6621 / 6622
10 Pages
-
SN 8310
7 Pages
-
CALYS 60 IS
9 Pages
-
CP 6632
7 Pages
-
THERMYS 150
10 Pages
-
CALYS 120 IS
12 Pages
-
ZX
5 Pages
-
OM 10
6 Pages
-
OM 21
8 Pages
-
ISOPALM 200
7 Pages
-
CRIT 100
4 Pages
-
IRtec P
11 Pages
-
FD 5 / 10 / 15
12 Pages
-
VNE20
5 Pages
-
OM 16
8 Pages
-
SATURN CYCLOP 878
4 Pages
-
CALYS 80 IS
11 Pages
-
CALYS 80P
10 Pages
-
P200 PRO
8 Pages
-
CALYS 150
8 Pages
-
motor starter
4 Pages
-
Frontdaq 10 isolated channels
4 Pages
-
Data Acquisition Systems DATALOG
12 Pages
-
Accuracy Thermometer PHP 602
2 Pages