CALYS 150 Advanced documenting multifunction calibrator thermometer
11Pages

{{requestButtons}}

Catalog excerpts

CALYS 150 Advanced documenting multifunction calibrator thermometer - 1

CALYS 150 Advanced documenting multifunction calibrator thermometer

Open the catalog to page 1
CALYS 150 Advanced documenting multifunction calibrator thermometer - 2

CALYS 150, most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer (IN / IN). It calibrates HART transmitters (HART communicator integrated) and thermistors. Description CALYS 150 field documenting multifunction calibrator is the top instrument of the range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, it can simultaneously measure and generate over two isolated channels various signals of temperature,...

Open the catalog to page 2
CALYS 150 Advanced documenting multifunction calibrator thermometer - 3

Connect your probes by simply pushing on the terminal top and insert wires of up to 3 mm or 10 AWG diameter and compensated thermocouple connectors. Wires are held tight between two brass plates ensuring thermal stability and a very good cold junction compensation for thermocouples. This system also enables 4 mm banana plugs and security connectors to be connected on the terminal top. CALYS series, 4 models from basic use to advanced performances Specifications Temperature accuracy DC current + Loop supply 24 V Range Accuracy Range Accuracy Range Accuracy Range Accuracy Range Accuracy...

Open the catalog to page 3
CALYS 150 Advanced documenting multifunction calibrator thermometer - 4

treatment AMS 2750 Additional functions Additional functions Advanced data exploitation: Scaling, relative measurement, simulation of ramps and steps, synthetizer, square root, statistical functions Transmitter function Switch test Calibration of transmitters Additional functions Comparison calibration HART: Digital calibration and data transfer Calibration of thermistors DATACAL calibration software for configuration and data management 10,000 data stored and recalled on screen as curve or list

Open the catalog to page 4
CALYS 150 Advanced documenting multifunction calibrator thermometer - 5

Specifications Specifications and performances in temperature @23°C ±5°C Uncertainty is given in % of reading (CALYS 150 display) + fixed value. Resistive probes: Measurement and simulation Sensor Range (Input and Output) Accuracy / 1 year (Measurement) Accuracy / 1 year (Simulation) Resistive probes measurements in 2, 3 or 4 wires: automatic recognition of number of connected wires, with indication on screen Accuracies are given for 4-wire mounted probes Take into account particular error of temperature sensor used and implementation conditions Admissible measuring current: 0.01 mA to 4 mA...

Open the catalog to page 5
CALYS 150 Advanced documenting multifunction calibrator thermometer - 6

Input range Accuracy / 1 Output year (Measur range ement) Accuracy / 1 year (Simulation)

Open the catalog to page 6
CALYS 150 Advanced documenting multifunction calibrator thermometer - 7

Thermocouples: PlatineL, Mo, NiMo/NiCo, G, D, L, C: For specifications, refer to the instruction manual (Available on request) Accuracy is given for reference @ 0°C. When using the internal reference junction (except couple B) add an additional uncertainty of 0.2 °C at 0 °C. It is possible (thermocouple B excepted) to choose by programming the cold junction localization: External at 0°C, internal (temperature compensation of instrument’s terminals) or manually entered. Temperature coefficient: <10% of accuracy /°C Display unit: °C and F. Thermistors: Measurement (Channel 1) With 50 Kohms...

Open the catalog to page 7
CALYS 150 Advanced documenting multifunction calibrator thermometer - 8

Specifications and performances in process @23°C ±5°C DC current: Measurement With or without loop supply Range Measurement range Temperature coefficient: < 7 ppm/°C from 0°C to 18°C and 28°C to 50 °C Loop supply: 24 V ± 10% HART® compatibility: Input impedance Rin = 280 Ω Display with linear or quadratic scaling DC voltage: Measurement Range Measurement range Frequency, counting: Measurement Range Scale unit: Pulse / min and Hz Trigger level: 1 V Measurement on frequency signals or dry contacts. Counting will be performed on defined time or infinite time. Resistance: Measurement Range...

Open the catalog to page 8
CALYS 150 Advanced documenting multifunction calibrator thermometer - 9

Resistance measurement in 2, 3 or 4 wires: automatic recognition of number of connected wires, with indication on screen Accuracies are given for 4-wire mounted probes DC current: Emission With or without loop supply Range Temperature Coefficient < 7 ppm/°C from 0°C to 18°C and 28°C to 50 °C Specifications given for CALYS 150 configurations in: - Active mode (+24V ON) 1 Meter in passive mode (+24 V OFF) - Passive mode (+24 V OFF) 1 Meter in active mode (+24 V ON) Pre-programmed steps 0% 25% 50% 75% 100% 4-20 mA linear 4 8 12 16 20 0-20 mA linear 0 5 10 15 20 4-20 mA quad 4 5 8 13 20 0-20 mA...

Open the catalog to page 9
CALYS 150 Advanced documenting multifunction calibrator thermometer - 10

Emission with pulsed current available: refer to the instruction manual for specifications Temperature coefficient: < 5 ppm/°C from 0°C to 18°C and 28°C to 50 °C. Current establishing time: <1ms Compatibility with smart transmitters Iext : Current received by the calibrator Further features Scaling in measurement and simulation modes Scaling allows process signals to be displayed in % of FS or in all other units. This function also allows sensors to be corrected after a calibration. Relative measurement

Open the catalog to page 10
CALYS 150 Advanced documenting multifunction calibrator thermometer - 11

Models and accessories Instrument: CALYS 150 On-site documenting multifunction calibrator Delivered in standard with: Quick start manual Battery charger Set of 6 testing leads Carrying strap Factory test report Accessories: ACL433 External digital pressure sensor for CALYS 75 / 100 / 150 (Absolute or relative pressure) Different ranges available from 0 to 1,000 bar Range from -1 -> 1; 3; 10; 30 (absolute or relative pressure) Range from -1 -> 100; 300; 1,000 (absolute pressure only) Standard accuracy: 0.05% FS AN6050 Transport case for CALYS series ACL9311 Set of 6 measuring cables with...

Open the catalog to page 11

All AOIP catalogs and technical brochures

  1. DRAGO 934

    5 Pages

  2. CALYS 1200

    10 Pages

  3. CALYS 1000

    10 Pages

  4. RAYOMATIC 16

    7 Pages

  5. RLV

    5 Pages

  6. EPM

    10 Pages

  7. UNIGAS 3000

    7 Pages

  8. RN 5306

    5 Pages

  9. TTI 10

    6 Pages

  10. RN 5360

    5 Pages

  11. MEGOHM 200

    7 Pages

  12. MF 28

    6 Pages

  13. IND 45

    6 Pages

  14. CALYS 1500

    12 Pages

  15. RAYOMATIC PE

    6 Pages

  16. IRTEC P IVT

    5 Pages

  17. RAYOMATIC TC

    6 Pages

  18. ICO 51

    6 Pages

  19. LKS 1000

    5 Pages

  20. MILLIK

    7 Pages

  21. TC 6621 / 6622

    10 Pages

  22. SN 8310

    7 Pages

  23. CALYS 60 IS

    9 Pages

  24. CP 6632

    7 Pages

  25. THERMYS 150

    10 Pages

  26. CALYS 120 IS

    12 Pages

  27. ZX

    5 Pages

  28. OM 10

    6 Pages

  29. OM 21

    8 Pages

  30. ISOPALM 200

    7 Pages

  31. CRIT 100

    4 Pages

  32. IRtec P

    11 Pages

  33. FD 5 / 10 / 15

    12 Pages

  34. VNE20

    5 Pages

  35. OM 16

    8 Pages

  36. CALYS 80 IS

    11 Pages

  37. CALYS 80P

    10 Pages

  38. P200 PRO

    8 Pages

  39. CALYS 150

    8 Pages

Archived catalogs