CALYS 1200 Precision documented multifunction calibrator
Open the catalog to page 1CALYS 1200 is a field documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, it can simultaneously measure, generate and record over two isolated channels various signals of temperature, pressure, resistance, process and frequency in one single instrument. Description CALYS 1200 is a field documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for...
Open the catalog to page 2Graphic screen and display resolution CALYS 1200 allows the digit number after the dot to be selected: This function is justified by the needs of users who want or not to display the best resolution for calibration or on the contrary limit it for simple verifications. CALYS 1200 dual display indicates permanently the measurement value, and also the emitted value, the gauge and the used functions. On the top date, time and also external temperature are also indicated. During measuring average, maximum, minimum and the number of measurements are displayed on the left. While for emission this part...
Open the catalog to page 3Specifications Performances & technical specifications in temperature @23°C ±5°C Uncertainty is given in % of reading + fixed value. Resistive probes: Measurement and simulation Probe type Resistive probes measurements in 2, 3 or 4 wires: automatic recognition of number of connected wires, with indication on screen. Accuracies are given for 4-wire mounted probes. Take into account particular error of temperature sensor used and implementation conditions. Temperature coefficient: < 10% of accuracy /°C Measuring current: 0.25 mA (Measurement) or from 0.1 to 1 mA (Emission) Settling time: < 1 ms...
Open the catalog to page 4Thermocouples: Measurement and simulation Type
Open the catalog to page 5Accuracy is given for reference @ 0°C. When using the internal reference junction (except for couple B) add an additional uncertainty of 0.2 °C at 0 °C. It is possible (except for thermocouple B) to choose by programming the cold junction localization: External at 0°C, internal (temperature compensation of instrument’s terminals) or manually entered. Temperature coefficient: <10% of accuracy /°C Display unit: °C and F Thermocouples G, D: Spécifications on instruction manual available on request Specifications and performances in pressure @23°C ±5°C> Pressure: Measurement by external digital sensor...
Open the catalog to page 6Available in relative, absolute and differential pressure. Connector: ¼ gas Resolution: 0.02% FS Accuracy: - 0.05% FS from 10 to 40°C - 0.1% FS from -10 to +10°C and from 40 to 80°C This digital pressure module ACL433 is connected to CALYS 1200 through RS485 serial cable to the digital input connector. All data are digital. Measurements are compensated in temperature by a polynomial correction implemented into the firmware at factory. Performances & technical spécifications in process @23°C ±5°C DC current: Measurement Range Rin: < 25 Ω With or without loop supply (24 V) For measurements of transmitter...
Open the catalog to page 7Direct voltage: Measurement Range Rin: input resistance Temperature coefficient: < 7 ppm/°C beyond reference domain Direct voltage: Emission Range Iout: output current from transmitter Temperature coefficient: < 7 ppm/°C beyond reference domain Settling time: < 5 ms Resistance: Measurement Range 2, 3 or 4 wires resistance measurement: automatic recognition of number of connected wires, with indication on screen Accuracies are given for 4-wire mounted probes Temperature coefficient: < 7 ppm/°C beyond reference domain Open circuit terminal voltage: < 10 V Continuity test: Open circuit for R > 1000...
Open the catalog to page 8Temperature coefficient: < 7 ppm/°C beyond reference domain Current settling time: < 1 ms Iext : Current received by the calibrator Frequency and counting: Measurement Range Temperature coefficient: < 5 ppm/°C beyond reference domain Scale unit: Pulse / min and Hz Trigger level: 1 V Measurement on frequency signals or dry contacts Counting will be performed on defined time or infinite time Frequency and pulses: Emission Range Temperature coefficient: < 5 ppm/°C beyond reference domain Scale unit: Pulse / min and Hz Pulse emission and dry contact simulation Max amplitude: 20 V selectable by user...
Open the catalog to page 9Models and accessories Instrument: CALYS1200 Precision documenting multifunction calibrator Delivered in standard with: Quick start manual Battery charger Set of 6 testing leads Factory test report Accessories: ACL433 External digital pressure sensor, range to be specified at the order: Absolute or relative pressure: Range from -1 -> 1; 3; 10; 30 bar Absolute pressure: Range from -1 -> 100; 300; 1000 bar ACL9311 Set of 6 measuring cables with removable crocodile clips ER 49504-000 USB cable Software: DATACAL Calibration software for CALYS 1000 / 1200 / 1500 Supplied with USB cable Certification:...
Open the catalog to page 105 Pages
10 Pages
6 Pages
5 Pages
10 Pages
5 Pages
6 Pages
7 Pages
7 Pages
5 Pages
7 Pages
6 Pages
6 Pages
12 Pages
6 Pages
6 Pages
5 Pages
6 Pages
6 Pages
6 Pages
6 Pages
5 Pages
7 Pages
8 Pages
10 Pages
7 Pages
9 Pages
7 Pages
10 Pages
12 Pages
5 Pages
6 Pages
8 Pages
7 Pages
4 Pages
11 Pages
12 Pages
5 Pages
8 Pages
4 Pages
11 Pages
6 Pages
8 Pages
4 Pages
10 Pages
12 Pages
4 Pages
2 Pages
6 Pages