An ideal blend of design, technology and wellness, bioclimatic pergolas make it possible to obtain an outdoor structure that is perfectly integrated within the residential or contract context, contributing to the reduction of polluting processes with a significant advantage for the environment. ANTUATOR manufactures in-line type linear actuators for motorized bioclimatic pergolas. Easy to install and use, they allow precise and complete control of environments. They are maintenance-free, clean and environmentally-friendly.
Open the catalog to page 2ANTUATOR'sANT-38P is created specially for the bioclimatic pergola market. Comes withahighlPdegree, metal housing, in-line design, long life span and compatible with most control systems, ANT-38P can be perfect solution for all kinds of pergola system. - Max speed at max load: 2.3mm/s -IP rating: IP67M/IP69K - Options: hall sensor, over current protection
Open the catalog to page 3DIMENSION Aluminum Version (mm) The dimensional tolerance not shown in the drawing can refer to IS02768-mk Stainless Steel Version (mm) The dimensional tolerance not shown in the drawing can refer to IS02768-mk
Open the catalog to page 4SPECIFICATIONS AND OPTIONS Voltage 12VDC 24VDC Push force Pull force Self-locking force Speed on load No load speed
Open the catalog to page 5CURVE Accuracy of speed or current: ±15%, in general, applications in the dashed are not recommended. MOUNTING BRACKETS
Open the catalog to page 6Installation: © Because of max force 2500N, the ANT-38P can be mounted in the middle position to work 2 pergolas. ©Very compact in-line design enable the actuator be mounted inside of the frame. ©Totally water proof design for outdoor using.
Open the catalog to page 8OVER CURRENT PROTECTION Over current protection can be added to the actuator,when the actuator extends to full stroke or overloaded.it will protect the actuator by limiting motors current.The function of over current protection is to protect the actuator from damage. (Circuit breaking current A) - The anode(+) and cathode(-) for input and output circuit can be interchangeable, input voltage is DC12V or DC24V. - The circuit breaking response time is 0.1-0.5s. - The ambient temperature range must be -20°C to 60°C and storage temperature is-40°Cto+70°C. - Max duty cycle is 10% or 2 minutes in use...
Open the catalog to page 9HALLSENSORWIRE DIAGRAM White Hall sensor B Vout Green Hall sensor A Vout Red Hall sensor VCC + Black Hall sensor GND -Blue Motor-Brown Motor+ • Two channel Hall sensor PNP type Hall sensor can be added to the actuator and the function of hall sensor Is to provide a signal feedback to the receiver to judge the motor speed. If we know how many signals hall sensor can produce in one circle,we will know how many signals the hall sensor can provide to the receiver when the motor runs one circle and then we can control the actuator speed and stroke precisely. Hall sensor resolution=Lead screw pitch/...
Open the catalog to page 10| ANT-26NFeatures and Benefits - Max load: 500N (push/pull) - Max speed at max load: 4mm/s -IP rating: IP66/IP67 - Options: hall sensor, over current protection
Open the catalog to page 11SPECIFICATIONS AND OPTIONS Voltage 12 24 Push force Pull force Self-locking force Speed on load No load speed
Open the catalog to page 12CURVE Accuracy of speed or current: ±15%, in general, applications in the dashed are not recommended. CURVE (Force/ current) Current(A)-24VDC Force(N) Pull-push force MOUNTING BRACKETS
Open the catalog to page 13- Options: hall sensor, over current protection Standard means without any additional function(Over current protection,hall sensor) The dimensional tolerance not shown in the drawing can refer to IS02768-mk
Open the catalog to page 14| ANT-52Features and Benefits - Max load: 6000N (push/pull) - Max speed at max load: 3mm/s -IP rating: IP66/IP67M - Options: hall sensor, over current protection
Open the catalog to page 16Stainless Steel Version (mm) Standard means without any additional function (Over current protection, hall sensor) The dimensional tolerance not shown in the drawing can refer to IS02768-mk Life tlme(cycles) 2>10k Wire length(m) 1.5
Open the catalog to page 17CURVE Accuracy of speed or current: ±15%, in general, applications in the dashed are not recommended. CURVE(Force/ current) CURVE( Force/ current) Current (24V)
Open the catalog to page 18Ordering Key:ANT-38P-AL-L-24-800-7-100/400-S-LSN-W-S ® (D (D © © © ® ®/@ © © @@ (D Brand:ANT (D Model: 26N,38P,45,52 © Materials: AL=Aluminum, S/S=Stainless Steel © Motor noise: L=Low noise version © Voltage: 24=24VDC, 12 = 12VDC © Load capacity: X=N ® Speed at load: X=mm/s © Stroke length: X=mm © Fully retracted length: X=mm © Housing color: S=Silver © Added function: LSC= Limit switch+over current protection LSH= Limitswitch + Hall sensor © Protection Class: W=IP67M © Frontfixture type: S=Special design C=Clevis type
Open the catalog to page 19Waterproof Precision, Smart Integration Add: Room 604, BlockA, No.199 Jinwan Road, Pudong New Area, Shanghai Web-.www.antuator.com E-mail: [email protected] ForSpanish market, please contact: Nice Automatismos Espana S.A. Cl Puerto Navafria, 11 y13 Pol. Ind. Expansion Mostoles 28935 Madrid [email protected] +34 919 616 33 00
Open the catalog to page 2028 Pages
31 Pages