SAPPHIRE® PLUS Total Flood Fire Suppression System

SAPPHIRE® PLUS Total Flood Fire Suppression System

SAPPHIRE® PLUS Total Flood Fire Suppression System

Product catalog summary
Overview: The document is a data sheet for the SAPPHIRE® PLUS Total Flood Fire Suppression System by ANSUL®, utilizing 3M™ Novec™ 1230 Fire Protection Fluid. It highlights features, applications, specifications, and ordering information.
Features: The system is UL/ULC Listed, FM Approved, and meets EN 12094 standards. It is designed according to NFPA 2001, EN 15004, and ISO 14520. The system offers electric, pneumatic, or manual operation and supports centralized storage with reduced pipe diameters.
Applications: Suitable for data centers, electrical switching rooms, machinery spaces, medical facilities, heritage sites, air traffic control, and oil and gas facilities.
Description: The SAPPHIRE PLUS system uses a storage pressure of 1,015 psi (70 bar), allowing for flexible system layout and the use of smaller pipe diameters. Selector valves enable protection of multiple areas with one container bank.
Approvals and Listings: The system is UL/ULC Listed, FM Approved, and CE Marked.
Specifications:
  • Environmental Data: Ozone Depletion Potential (ODP) is 0, Global Warming Potential (GWP) is 1, and Atmospheric Lifetime (ALT) is 3 to 5 days.
  • Operating Temperature: 0 °F to 122 °F (-18 °C to 50 °C) for UL, FM, and CE; 32 °F to 149 °F (0 °C to 65 °C) for UL and FM.
  • Physical Properties of Novec 1230 Fluid: Molecular weight is 316.04, boiling point is 120.6 °F (49.2 °C), and freezing point is -162.4 °F (-108.0 °C).
Ordering Information: The document provides detailed part numbers and specifications for different container sizes and configurations from manufacturing locations in the USA, UK, and India. It includes dimensions, weight, and temperature ratings.
See more

Catalog excerpts

SAPPHIRE® PLUS Total Flood Fire Suppression System-1

DATA SHEET SAPPHIRE® PLUS Total Flood Fire Suppression System Features n  UL/ULC Listed and FM Approved n  ully meets EN 12094 F n  esigned according to NFPA 2001, EN 15004, and ISO 14520 D n  L and FM verified software U n  elector valve systems S n  vailable with standard pressure gauge or contacted A pressure gauge for pressure monitoring n  lectric, pneumatic, or manual operation E n  entralized storage locations C n  educed pipe diameters for traditional systems R Applications The ANSUL® SAPPHIRE® PLUS Total Flood Fire Suppression System utilizes 3M™ Novec™ 1230 Fire Protection Fluid as the suppression agent. Novec 1230 fluid is effective for the following total flooding fire suppression applications: n Data centers n  lectrical switching rooms E n Machinery spaces n Medical facilities n  eritage and cultural sites H n  ir traffic control A n  il and gas facilities O Specifications Environmental Data Ozone Depletion Potential (ODP) Global Warming Potential (GWP) Atmospheric Lifetime (ALT) Operating and storage temperature Note: Temperature range is dependent on fill density and nozzle coverage. For details, refer to the latest revision of the SAPPHIRE PLUS Total Flood Fire Suppression System Manual (Part No. 571000). Description Conventional SAPPHIRE systems use a storage pressure of 363 psi (25 bar) or 609 psi (42 bar), which is suitable for many applications. The SAPPHIRE PLUS system uses a storage pressure of 1,015 psi (70 bar) to provide the designer with more flexibility when planning the layout of the system. This superpressurization means the containers can be placed further from the hazard area, if required. The use of smaller pipe diameters, and the use of selector valves help to protect multiple areas using one bank of containers. Approvals and Listings n  UL/ULC Listed n  FM Approved n  CE Marked Physical Properties of 3M Novec Properties Molecular weight Boiling point at 1,013 bar (absolute) Freezing point Vapor pressure 68 °F (20 °C) Liquid density 68 °F (20 °C) Saturated vapor density 68 °F (20 °C) Heat of vaporization at boiling point Chemical formula Chemical name * bar = 0.1 MPa = 100,000 Pa = 14.5 psi; 1 1 MPa = 1 N/mm2 Safety Data Sheets (SDS) are available at www.ansul.com One Stanton Street  |  Marinette, WI 54143-2542, USA  | +1-715-735-7411 | www.ansul.com © 2018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revisi

 Open the catalog to page 1
SAPPHIRE® PLUS Total Flood Fire Suppression System-2

Ordering Information From Marinette, Wisconsin, USA (UL/ULC Listed and FM Approved) Standard1 Contacted1 DOT*/TPED Gauge/Con. Gauge/Con. Nom. Size | Temp. Part No. Part No. L (lb) | °F (°C) Height to Outlet Diameter in. (mm) in. (mm) Manifold Bracket Height with AHA in. (mm) * anada and the USA mutually recognize the regulatory approvals for UN pressure receptacles. This means that UN pressure receptacles manufactured in C accordance with 49 CFR (Code of Federal Regulations) marked with USA as the country of approval, commonly referred to as DOT, satisfy the TC requirements. From Great Yarmouth,...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.