5000W Single Output Power Supply Bauar t ge pru ft Sicherheit eg el ma ge od o s be wac g ww w.tuv.com ID 200 0000 000 ■ Features ‧3ψ 3-wire / △ 196~305VAC or 3ψ 4-wire / Y 340~530VAC wide input range ‧Built-in active PFC function ‧High efficiency up to 91% ‧Protections: Short circuit / Overload / Over voltage / ■ Applications ‧Industrial control equipments ‧ Automation equipments ‧ Laser engravers ‧ Telecommunication systems Over temperature / Fan fail ‧Forced air cooling by built-in fan with speed control function ‧Output voltage can be trimmed between 20~120% by 1~6VDC external control signal ‧Output current can be trimmed between 20~100% by 1~5VDC external control signal ‧Current sharing up to 3 units ‧Alarm signal output (relay contact and open collector signal): AC fail, DC OK, fan fail, OTP ‧Built-in 12V/0.1A auxiliary output for remote control ‧Built-in remote ON/OFF control ‧Built-in remote sense function ‧5 years warranty ■ Description RST-5000 is one 5000W single output enclosed type AC/DC power supply series. This series accepts the wide range 3-phase AC input (3ψ 3-wire / △ 196~305VAC or 3ψ 4-wire / Y 340~530VAC) and supplies 24VDC and 48VDC at the output. RST-5000 particularly provides the wide range adjustment function for output voltage and current by means of an external control signal; moreover, RST-5000 offers two overload protection mechanisms, the “continuous constant current limiting” mode and the “constant current limiting with delay shutdown after 5 seconds” mode, well providing the flexibility for high power system design. RST-5000 has the built-in active PFC function and the working efficiency is high up to 91%. With the builtin fan, the entire series can supply the full load output under 50℃ ambient temperature. The parallel function is bui lt to transmit an even higher power with up to 3 units. Other functions include the remote sense function, the 12V/0.1A auxiliary power, the alarm signal output (both relay contact and open collector signal) for AC fail, DC OK, fan fail and over temperature protection, and etc. RST-5000 series acquires the major global safety regulation certificates. ■ Model Encoding RST - 5000 - 24 Output voltage Output wattage Series name
Open the catalog to page 15000W Single Output Power Supply SPECIFICATION MODEL RST-5000-24 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER 4800W RIPPLE & NOISE (max.) Note.2 150mVp-p OUTPUT VOLTAGE ADJ. RANGE Note.4 23.5 ~ 28.8V VOLTAGE TOLERANCE Note.3 ±1.0% LINE REGULATION ±0.5% LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE AUXILIARY POWER(AUX) REMOTE ON/OFF CONTROL FUNCTION ALARM SIGNAL OUTPUT OUTPUT VOLTAGE TRIMMING OUTPUT CURRENT TRIMMING CURRENT SHARING WORKING TEMP. WORKING HUMIDITY...
Open the catalog to page 25000W Single Output Power Supply Block Diagram PFC fosc : 70KHz PWM fosc : 100KHz +S RECTIFIERS & PFC RECTIF IERS & FI LTER POWER SWITCHING DETECTION CIRCUIT CURRENT LIMIT CONTROL CIRCUIT O.V.P. CS PV PC RC DC-OK AC-FAIL FAN-FAIL OTP ISOLATOR & RELAY RECTIF IERS & FI LTER Derating Curve Static Characteristics
Open the catalog to page 35000W Single Output Power Supply Function Description of CN313, 314 Pin No. Function Description 1 Current sharing signal. When units are connected in parallel, the CS pins of the units should be connected to allow current balance between units. Please refer to the Function Manual section for details. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. Connect to external DC voltage source for output voltage trimming. Output voltage can be trimmed between...
Open the catalog to page 45000W Single Output Power Supply 2.Remote Sense The remote sense function compensates the voltage drop on the cable, between the PSU and the load, up to 0.3V. If the remote sense function is not required, +S and +V, as well as -S and -V, need to be connected to be free from noise and interference. (+S and +V, -S and -V are connected as factory default setting) +V +S -S -V +V LOAD -V Sense lines should be twisted in pairs Fig 2.1 3.Select PV mode (Output Voltage Trimming) 1 2 3 (1)Have the DIP switch set as ON OFF (2)Connecting an external DC source between PV+ and PV- on CN313 or CN314. +S and...
Open the catalog to page 55000W Single Output Power Supply 5.Select OLP Mode RST-5000 provides two selectable overload mechanisms by switching DIP switch position-1. (1)Continuous Constant Current mode Switch DIP switch position-1 to lower position(OFF), and RST-5000 will work in contiunous constant current mode when the output is overloaded or ‧ short-circuited. (2)Delay Shutdown mode Switch DIP switch position-1 to upper position(ON), and RST-5000 will shut down after 5 seconds, the so-called Delay Shutdown, when the output is ‧ overloaded or short-circuited. 6.Front Panel Indicators LED LED on when output voltage is...
Open the catalog to page 65000W Single Output Power Supply 8.Current Sharing (1)Parallel operation is available by connecting the units shown as follows. (+S,-S and CS+, CS- and RC+, RC- are connected mutually in parallel.) (2)The voltage difference among each output should be minimized that less than 0.2V is required. (3)The total output current must not exceed the value determined by the following equation. (Output current at parallel operation)=(The rated current per unit)x(Number of unit)x0.9 (4)In parallel operation 3 units is the maximum, please consult the manufacturer for other applications. (5)When the remote...
Open the catalog to page 75000W Single Output Power Supply ■Note : RST-5000 can also be operated by 1ψ2 - wire 196~305VAC input. Please refer to the connection diagram below. Operating with 1ψ2 - wire may lead to certain characteristics different from the specification, such as the larger Ripple and Noise. Should there be any issues, please contact MEAN WELL. L
Open the catalog to page 85000W Single Output Power Supply Mechanical Specification Control Pin No. Assignment(CN313,CN314) : HRS DF11-10DP-2DS or equivalent Assignment AC/N2 AC/L3 AC/N3 Mating Housing DIP Switch Position Assignment(DIP-SW): Please refer to the Function Manual. Position 1 2 Assignment OLP mode PC mode Installation Manual Please refer to : http://www.meanwell.com/we bnet/search/Installation Search.html
Open the catalog to page 94 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
5 Pages
16 Pages
3 Pages
14 Pages
3 Pages
6 Pages
7 Pages
2 Pages
9 Pages
5 Pages
5 Pages
6 Pages
6 Pages
9 Pages
8 Pages
11 Pages
9 Pages
5 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
33 Pages
39 Pages
37 Pages
4 Pages
4 Pages
4 Pages
14 Pages
15 Pages
14 Pages
11 Pages
7 Pages
20 Pages
5 Pages
5 Pages
5 Pages
6 Pages
10 Pages
6 Pages
5 Pages
11 Pages
4 Pages
6 Pages
4 Pages
5 Pages
5 Pages
4 Pages
5 Pages
6 Pages
5 Pages
5 Pages
6 Pages
4 Pages
7 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
16 Pages
3 Pages
5 Pages
25 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
3 Pages
11 Pages
16 Pages
2 Pages
12 Pages
6 Pages
5 Pages
3 Pages
3 Pages
2 Pages
3 Pages
3 Pages
11 Pages
4 Pages
3 Pages
7 Pages
3 Pages
4 Pages
3 Pages
2 Pages
2 Pages
14 Pages
3 Pages
3 Pages
4 Pages
3 Pages
9 Pages
5 Pages
3 Pages
3 Pages
5 Pages
5 Pages
6 Pages
5 Pages
6 Pages
13 Pages
3 Pages
5 Pages
5 Pages
5 Pages
4 Pages
5 Pages
3 Pages
8 Pages