General description Features The PHPS 5600 is pressure transducer in a miniature metal housing for industrial applications. Input pressure is sensed with silicon piezoresistive bridge. Measured pressure is transformed into standard output voltage range from 0.5 to 4.5 V or other. A switching output is integrated in transducer, which can be externally adjusted with potentiometer and switching level seen with LED indicator. Temperature compensation and calibration is performed by programmable digital signal conditioner. Wide supply range 7 to 40 V, standard 0,5 to 4,5 V voltage output, digital output and switching output provides users maximum freedom for any type of application with dry air or non-corrosive gases and liquids. Small size and robust M8 threaded housing is very convenient for applications with limited space. Total length is less than 40 mm with standard M8 electrical connector. The whole group consists of pressure ranges from 20 mbar to 7 bar. Gage pressure configuration available for this group. • Wide supply voltage range 7 to 40 V • Wide compensated range (0 to 70°C) • Total accuracy down to 0,5%FS over 0 to 70°C, all effects included (maximum) • Digital I2C output up to 15 bits (pressure + temperature) • Overcurrent and overvoltage protection • Overload and short circuit protection • Integrated EMC protection • High performance OEM applications • Standard M8 output connector • Gage pressure configuration Applications • Industrial process control • Pressure transducer • Air flow monitoring • Process control • Leak detection • Pneumatic controls Competitive sensor & power supply solutions wo
Open the catalog to page 1Competitive sensor & power supply solutions worldwide
Open the catalog to page 2Competitive sensor & power supply solutions worldwide
Open the catalog to page 31) Over pressure is the maximum pressure which may be applied without causing damage to the sensing element. 2) Burst pressure is the maximum pressure which may be applied without causing leakage damage to the sensing element. 3) Digital signal is non-ratiometric to the power supply Vcc. 4) Offset voltage is the voltage output at zero pressure. 5) Full scale output is the voltage output at full pressure range. 6) Full scale span is the algebraic difference between the output at full scale pressure range and offset. 7) Digital output signal (temperature) is not ratiometric to power supply...
Open the catalog to page 4Pressure range Pressure type Pressure direction Transducer type Competitive sensor & power supply solutions worldwide
Open the catalog to page 5Headquarter Switzerland: Pewatron AG Thurgauerstrasse 66 CH-8050 Zurich Phone +41 44 877 35 00 info@pewatron.com Office Germany: Pewatron Deutschland GmbH EdisonstraEe 16 D-85716 UnterschleiEheim Phone +49 89 374 288 87 00 info.de@pewatron.com PEWATRON 5ENS0R5 • POWER SOLUTIONS We are here for you. Addresses and Contacts. Sales Germany & Austria Geometrical sensors Other products Kurt Stritzelberger Phone + 49 89 374 288 87 22 kurt.stritzelberger@pewatron.com Pressure sensors Other products Gerhard Vetter Phone + 49 89 374 288 87 26 gerhard.vetter@pewatron.com Sales Switzerland &...
Open the catalog to page 6All Angst+Pfister Sensors and Power AG catalogs and technical brochures
-
SQ-UST_L_0105-01
4 Pages
-
SQ-UST_L_0104-01
4 Pages
-
SQ-UST_L_0103-01
4 Pages
-
SQ-UST_L_0003-01
3 Pages
-
SQ-UST_L_0002-01
3 Pages
-
SQ-UST_L_0001-01
3 Pages
-
PFLOW Series
5 Pages
-
Model PFLOW3000 Series
16 Pages
-
LoadSensor StarterKit
3 Pages
-
Model PFLOW2001 Series
14 Pages
-
PSB82_1685-21629-0010-E-1118
3 Pages
-
PEWA200 Pressure Transmitter
7 Pages
-
PZA-MC25-N/P
2 Pages
-
PEWA100
9 Pages
-
HLP-80H series
5 Pages
-
HLP-40H series
5 Pages
-
HBG-60P series
6 Pages
-
UHP-750 series
6 Pages
-
XLG-50 seri es
9 Pages
-
DAP-04 series
8 Pages
-
POB-30 series
11 Pages
-
RHP-1U Rack System
9 Pages
-
RFP-M8M4-5A
5 Pages
-
RFP-M5M3-3A
4 Pages
-
RFP-M2M3-3A
4 Pages
-
RFP-M1M3-3A
4 Pages
-
NCL CL1 01
4 Pages
-
IRL RGB 01
4 Pages
-
IRL CL2 01
4 Pages
-
MSR385WD
3 Pages
-
MSR145WD
3 Pages
-
MSR 145
3 Pages
-
M2029
3 Pages
-
MSR165
3 Pages
-
CRM102.1
33 Pages
-
CRM200
39 Pages
-
CRM100
37 Pages
-
FPM
4 Pages
-
FGN
4 Pages
-
FPN
4 Pages
-
PBM220-A14N series
14 Pages
-
PBM220 series
15 Pages
-
PBM210-A20K Series
14 Pages
-
STX Series – Model 13A
11 Pages
-
CCD Series – Model 53A
7 Pages
-
CCD Series – Model 54D
20 Pages
-
APB2Series
5 Pages
-
AP4Series
5 Pages
-
AP2Series
5 Pages
-
PHPS-7500 OEM
6 Pages
-
PPCP3-M1
10 Pages
-
AG4Series
6 Pages
-
AG2Series
5 Pages
-
New Pewatron brochure
11 Pages
-
GST220A
4 Pages
-
GSM40B
6 Pages
-
GSM36B
4 Pages
-
GSC25E
5 Pages
-
TDR-480
5 Pages
-
GC120
4 Pages
-
HDR-30
5 Pages
-
GSM220A
6 Pages
-
EPP-400
5 Pages
-
ENP-120
5 Pages
-
ENC-120
6 Pages
-
ATX-100
4 Pages
-
RPS-200
7 Pages
-
APBR30X75
2 Pages
-
APBR30X60
2 Pages
-
APBR 30X50 MM
2 Pages
-
PSB54/16
2 Pages
-
PSB54/14
2 Pages
-
PSB36T/16
2 Pages
-
PSB35T/12
2 Pages
-
PSB25T/16
2 Pages
-
PSB25T/12
2 Pages
-
PSB21/12
2 Pages
-
PSB 21
2 Pages
-
AD-Series
16 Pages
-
DMU11
3 Pages
-
HDR-30 series
5 Pages
-
DMU30-01
25 Pages
-
DMU30
3 Pages
-
DKA30 serie s
2 Pages
-
DCW12
2 Pages
-
DCW05
2 Pages
-
EH - EF 80 C/P/K
3 Pages
-
7S Series
3 Pages
-
Model CE36M
3 Pages
-
EX 80 A
3 Pages
-
STX13A-D_100-31-410-005-EH-0817
11 Pages
-
PBM220_100-33-421-003-EH-1216
16 Pages
-
ABS5_100-33-102-001-EH-1016
2 Pages
-
PHPS-8500_100-31-331-003-EH-0617
12 Pages
-
100 33 102 012 EH 0315
6 Pages
-
100 33 102 007 EH 0315
5 Pages
-
UFO
3 Pages
-
UFO-M2
3 Pages
-
Dummy DC-Motoren
2 Pages
-
FCX-MP1000-Extern-FH-CH
3 Pages
-
GC30E
3 Pages
-
RPS-400
11 Pages
-
GC 330
4 Pages
-
EL30
3 Pages
-
EA PROFIBUS
7 Pages
-
EAMW
3 Pages
-
AAM58
4 Pages
-
EAM36
3 Pages
-
CARBONOXY25
2 Pages
-
CARBONDIO-%
2 Pages
-
FCX-ML25-EXTERN-CH
14 Pages
-
FCX-MC25-CH
3 Pages
-
FCX-MC05-CH
3 Pages
-
FCX-TR0025
4 Pages
-
LP-10HA
3 Pages
-
FCX-UC-CH
9 Pages
-
901.1-EX
5 Pages
-
FC22
3 Pages
-
MILLINEWTON
3 Pages
-
PFLOW10U-2210
5 Pages
-
901.1
5 Pages
-
HX-EP
6 Pages
-
VQ548MP & MP-7217
5 Pages
-
Air quality sensing
6 Pages
-
Tailor-made
10 Pages
-
RAZTEC
13 Pages
-
The SGX-SureCO
3 Pages
-
930 Climair
5 Pages
-
984 pressure transmitter
5 Pages
-
PEM pressure transmitter
5 Pages
-
Pressure sensor CCD54
4 Pages
-
MSP-600 600W AC/DC
5 Pages
-
FCX-MP1000-Extern-FH-CH
3 Pages
-
Pewatron_Flyer_EN
8 Pages