Features
  • Supply voltage ranges from 1.7 to 5.5V for VDD and 1.2 to 5.5V for VDDIO.
  • Pressure range up to 0.7MPa.
  • Fastest conversion time of 2.2ms.
  • Standby current is less than 0.1μA.
  • Supports I2C and SPI interfaces.
  • Calibrated and temperature compensated.
Application Examples
  • Sport watch
  • Diving watch
  • Smart watch
Descriptions

The PBM220 series is a high-resolution digital barometer featuring a MEMS piezoresistive pressure sensor and a signal conditioning ASIC. It includes a 24-bit sigma-delta ADC, OTP memory for calibration data, and serial interface circuits. It supports both I2C and SPI interfaces for communication with microcontrollers. The sensor is designed for low power consumption and is suitable for portable or battery-powered devices. It is water-resistant, meeting the ISO 2281 standard for 100m water resistance.

Ordering Information
  • PBM220-A07NDT: Absolute 0-0.7MPa, SPI/I2C, SMD JEDEC tray
  • PBM220-A07NDR: Absolute 0-0.7MPa, SPI/I2C, SMD Tape & Reel
  • PBM220-A07NDU: Absolute 0-0.7MPa, SPI/I2C, SMD Tube
Electrical Characteristics
  • Pressure range: 0 to 0.7 MPa
  • Operating temperature range: -40 to 85°C
  • Supply current varies with resolution settings, with ultra-high resolution consuming up to 16.0 μA.
  • Standby current is less than 0.1 μA.
  • Conversion times vary from 2.2ms to 10.7ms depending on resolution.
  • Absolute pressure accuracy is within ±5 kPa over the range of 0 to 0.7 MPa at 0 to 40°C.
Absolute Maximum Conditions
  • Supply Voltage: AVDD and VDDIO range from -0.3 to 6.5 V.
  • Storage Temperature Range: -40 to 125°C.
  • Maximum Overpressure: 3 MPa according to ISO 6425.
Application Information

The PBM220 requires an external microprocessor for calibration using data stored in OTP memory. It is suitable for portable devices due to its low power consumption and is designed for water-resistant applications.

Control Registers

Registers are used for data output, configuration, calibration, and control of the SPI interface. Specific addresses and default values are provided for each register.

SPI Interface

The SPI interface supports mode 0 (CPOL=0, CPHA=0) with a maximum clock frequency of 10 MHz. Timing specifications for setup and hold times are provided.

I2C Interface

The I2C interface uses SCL and SDA lines with a device address configured via the SDO/ADDR pin. The protocol includes start and stop conditions, with specific timing requirements for setup and hold times.

Package Information

Details on outline dimensions and recommended footprint are provided for the PBM220 package.

Tape and Reel Specification
  • Tape Dimensions: All dimensions are specified in millimeters.
  • Sensor Orientation: Details regarding the orientation of sensors relative to the tape are provided.
Document History and Modifications
  • Revision 0.1: First edition released on 2016/7/6.
  • Revision 0.2: Modifications include changes to noise in pressure and absolute pressure accuracy on page 4, and a change in product coding style, dated 2016/11/6.
Contact Information
  • Headquarters: Pewatron AG, Zurich, Switzerland. Phone: +41 44 877 35 00, Email: [email protected]
  • Germany Office: Pewatron AG, Munich, Germany. Phone: +49 89 260 38 47, Email: [email protected]
  • Sales Contacts: Various sales representatives are listed for different regions and product categories, including Kurt Stritzelberger, Basil Frei, Eric Letsch, Peter Felder, Gerhard Vetter, Thomas Clausen, Sebastiano Leggio, Christian Mohrenstecher, Philipp Kistler, and Roman Homa, with their respective contact details.
See more

Catalog excerpts

PBM220-07N_100-33-421-007-EH-0617-1

Features □ Supply voltage: 1.7 to 5.5V(Vdd) 1.2 to 5.5V(Vddio) □ 0.7MPa pressure range □ 2.2ms fastest conversion time □ Calibrated and temperature compensated Application Examples □ Sport watch □ Diving watch □ Smart watch Descriptions The PBM220 is a new generation of high resolution digital barometer. The PBM220 is a digital pressure sensor which consists of a MEMS piezoresistive pressure sensor and a signal conditioning ASIC. The ASIC include a 24bits sigma-delta ADC, OTP memory for calibration data, and serial interface circuits. The PBM220 could provide both I2C and SPI interface to communicate with microcontroller. Pressure calibrated and temperature compensated were key features of the PBM220. The data stored in OTP memory could be used to calibrate the PBM220. The calibration procedure should be implemented by an external microprocessor. The PBM220 is low power and supply voltage designed and suitable for portable devices or battery-supplied ones. The PBM220 is designed for water resistant applications. It could meet the criterion of 100m water resistant according to ISO 2281 standard. Ordering information Competitive sensor & power supply solutions worldwide

 Open the catalog to page 1
PBM220-07N_100-33-421-007-EH-0617-2

Competitive sensor & power supply solutions worldwide

 Open the catalog to page 2
PBM220-07N_100-33-421-007-EH-0617-3

1 Functional Block and Pin Descriptions Competitive sensor & power supply solutions worldwide

 Open the catalog to page 3
PBM220-07N_100-33-421-007-EH-0617-4

Competitive sensor & power supply solutions worldwide

 Open the catalog to page 4
PBM220-07N_100-33-421-007-EH-0617-5

Owing to state of the art, the PBM220 build a new standard of digital barometer. A 24bits sigma-delta ADC and a MEMS pressure sensor are integrated in a LGA substrate. Pressure calibrated and temperature compensated were key features of the PBM220. The PBM220 is low power and supply voltage designed and suitable for portable devices or battery-supplied ones. The data stored in OTP memory could be used to calibrate the PBM220. The calibration procedure should be implemented by a external microprocessor. By I2C or SPI interface, you can get the calibration data stored in OTP and the raw data of...

 Open the catalog to page 5
PBM220-07N_100-33-421-007-EH-0617-6

5 Control registers Table 5.1 control registers Reg 0xF6-0xF8 Data_out: 24 bits ADC output data Reg 0xF4 OSR<1:0>: 00:1024X, 01:2048X, 10:4096X, 11:8192X Measurement_control<5:0>: 101110, indicate a temperature conversion. 110100, indicate a pressure conversion. Reg 0xE0 Softreset : Write only register. If set to 0xB6, will perform a power on reset sequence. Auto returned to 0 after the soft reset completed. Reg {0xF1, 0xD0, 0xBB:0xAA} Calibration Registers : Total 20bytes calibration registers used for sensor calibration. Reg 0x6B PartID: 8 bits Part ID, the default value is 0x42. Reg 0x00 SDO_active:...

 Open the catalog to page 6
PBM220-07N_100-33-421-007-EH-0617-7

Table 5.2 Summary of instructions Competitive sensor & power supply solutions worldwide

 Open the catalog to page 7
PBM220-07N_100-33-421-007-EH-0617-8

Figure 6.1 SPI timing diagram The falling edge of CSB, in conjunction with the rising edge of SCLK, determines the start of framing. Once the beginning of the frame has been determined, timing is straightforward. The first phase of the transfer is the instruction phase, which consists of 16 bits followed by data that can be of variable lengths in multiples of 8 bits. If the device is configured with CSB tied low, framing begins with the first rising edge of SCLK. The instruction phase is the first 16 bits transmitted. As shown in Figure 5.2, the instruction phase is divided into a number of bit...

 Open the catalog to page 8
PBM220-07N_100-33-421-007-EH-0617-9

Data follows the instruction phase. The amount of data sent is determined by the word length (Bit W0 and Bit W1). This can be one or more bytes of data. All data is composed of 8-bit words. Data can be sent in either MSB-first mode or LSB-first mode (by setting ‘LSB_first’ bit). On power up, MSB-first mode is the default. This can be changed by programming the configuration register. In MSB-first mode, the serial exchange starts with the highest-order bit and ends with the LSB. In LSB-first mode, the order is reversed. (Figure 6.3) CSB \/ scl dqn-tcare\ nnnAnnnnnnfVinnnnfvinnnAiViAnnnnnnn(dqn'tcare...

 Open the catalog to page 9
PBM220-07N_100-33-421-007-EH-0617-10

Table 7.2 Electrical specification of the I2C interface pins The I2C interface protocol has special bus signal conditions. Start (S), stop (P) and binary data conditions are shown below. At start condition, SCL is high and SDA has a falling edge. Then the slave address is sent. After the 7 address bits, the direction control bit R/W selects the read or write operation. When a slave device recognizes that it is being addressed, it should acknowledge by pulling SDA low in the ninth SCL (ACK) cycle. At stop condition, SCL is also high, but SDA has a rising edge. Data must be held stable at SDA when...

 Open the catalog to page 10
PBM220-07N_100-33-421-007-EH-0617-11

DATA ACK START ADDRESS R/W ACK condition DATA ACK STOP Competitive sensor & power supply solutions worldwide

 Open the catalog to page 11
PBM220-07N_100-33-421-007-EH-0617-12

8.3.2 Sensor orientation relative to the tape Competitive sensor & power supply solutions worldwide

 Open the catalog to page 12
PBM220-07N_100-33-421-007-EH-0617-13

Competitive sensor & power supply solutions worldwide

 Open the catalog to page 13
PBM220-07N_100-33-421-007-EH-0617-14

Office Germany: Pewatron AG Neumarkter StraEe 86a D-81673 Munich Phone +49 89 260 38 47 [email protected] PEWATRON SENSORS ■ POWER SUPPLIES We are here for you. Addresses and Contacts. Postcode 1000 - 2999 Eric Letsch Pewatron AG Thurgauerstrasse 66 CH-8052 Zurich Phone + 41 44 877 35 14 Mobile + 41 76 491 66 70 [email protected] Sales International Key Accounts Sales Austria Sales Other Countries / Product Pressure Sensors Gas sensors / Gas sensor modules Load cells Thomas Clausen Phone + 41 44 877 35 13 [email protected] Linear position sensors Angle sensors Eric Letsch Phone...

 Open the catalog to page 14

All Angst+Pfister Sensors and Power AG catalogs and technical brochures

  1. PFLOW Series

    5  Pages

  2. PZA-MC25-N/P

    2  Pages

  3. PEWA100

    9  Pages

  4. DAP-04 series

    8  Pages

  5. POB-30 series

    11  Pages

  6. RFP-M8M4-5A

    5  Pages

  7. RFP-M5M3-3A

    4  Pages

  8. RFP-M2M3-3A

    4  Pages

  9. RFP-M1M3-3A

    4  Pages

  10. NCL CL1 01

    4  Pages

  11. IRL RGB 01

    4  Pages

  12. IRL CL2 01

    4  Pages

  13. MSR385WD

    3  Pages

  14. MSR145WD

    3  Pages

  15. MSR 145

    3  Pages

  16. M2029

    3  Pages

  17. MSR165

    3  Pages

  18. CRM102.1

    33  Pages

  19. CRM200

    39  Pages

  20. CRM100

    37  Pages

  21. FPM

    4  Pages

  22. FGN

    4  Pages

  23. FPN

    4  Pages

  24. PBM220 series

    15  Pages

  25. APB2Series

    5  Pages

  26. AP4Series

    5  Pages

  27. AP2Series

    5  Pages

  28. PHPS-7500 OEM

    6  Pages

  29. PPCP3-M1

    10  Pages

  30. AG4Series

    6  Pages

  31. AG2Series

    5  Pages

  32. GST220A

    4  Pages

  33. GSM40B

    6  Pages

  34. GSM36B

    4  Pages

  35. GSC25E

    5  Pages

  36. TDR-480

    5  Pages

  37. GC120

    4  Pages

  38. HDR-30

    5  Pages

  39. GSM220A

    6  Pages

  40. EPP-400

    5  Pages

  41. ENP-120

    5  Pages

  42. ENC-120

    6  Pages

  43. ATX-100

    4  Pages

  44. RPS-200

    7  Pages

  45. APBR30X75

    2  Pages

  46. APBR30X60

    2  Pages

  47. APBR 30X50 MM

    2  Pages

  48. PSB54/16

    2  Pages

  49. PSB54/14

    2  Pages

  50. PSB36T/16

    2  Pages

  51. PSB35T/12

    2  Pages

  52. PSB25T/16

    2  Pages

  53. PSB25T/12

    2  Pages

  54. PSB21/12

    2  Pages

  55. PSB 21

    2  Pages

  56. AD-Series

    16  Pages

  57. DMU11

    3  Pages

  58. HDR-30 series

    5  Pages

  59. DMU30-01

    25  Pages

  60. DMU30

    3  Pages

  61. DKA30 serie s

    2  Pages

  62. DCW12

    2  Pages

  63. DCW05

    2  Pages

  64. 7S Series

    3  Pages

  65. Model CE36M

    3  Pages

  66. EX 80 A

    3  Pages

  67. UFO

    3  Pages

  68. UFO-M2

    3  Pages

  69. GC30E

    3  Pages

  70. RPS-400

    11  Pages

  71. GC 330

    4  Pages

  72. EL30

    3  Pages

  73. EA PROFIBUS

    7  Pages

  74. EAMW

    3  Pages

  75. AAM58

    4  Pages

  76. EAM36

    3  Pages

  77. CARBONOXY25

    2  Pages

  78. CARBONDIO-%

    2  Pages

  79. FCX-MC25-CH

    3  Pages

  80. FCX-MC05-CH

    3  Pages

  81. FCX-TR0025

    4  Pages

  82. LP-10HA

    3  Pages

  83. FCX-UC-CH

    9  Pages

  84. 901.1-EX

    5  Pages

  85. FC22

    3  Pages

  86. MILLINEWTON

    3  Pages

  87. PFLOW10U-2210

    5  Pages

  88. 901.1

    5  Pages

  89. HX-EP

    6  Pages

  90. Tailor-made

    10  Pages

  91. RAZTEC

    13  Pages

  92. 930 Climair

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.