MSR165
3Pages

{{requestButtons}}

Catalog excerpts

MSR165 - 1

MSR 165 Data Logger for shock and vibration The data logger, which is equipped with a high resolution 3-axis acceleration sensor (± 15 g or ± 200 g), supplies valuable measured data about shocks, jolts and vibrations. With its measurement frequency of 1600/s, high-capacity memory and low power requirements, the MSR 165 is ideal for applications in the fields of transportation monitoring, fault diagnoses and load tests. The memory capacity of over two million stored measured values is sufficient for recording 10,000+ shocks; it can be extended to more than 1 billion measured values by using a microSD card. The measured data can be quickly transferred to a computer via the USB port or microSD card. The MSR PC software allows you to efficiently record and process the measured data. NEW: For extensive analysis and graphical representation of the data recorded in shock mode and to automatically create reports, the new MSR ShockViewer analysis software, which is specifically tailored to the requirements of transportation monitoring, is at your disposal. Technical data Housing: Size & weight: Anodised aluminium case, PC, encapsulated, waterproof (IP67) 39 x 23 x 72 mm, approx. 69 g Medium: Memory capacity: Colour: Key: Air, various liquids Over 2m measurement values, expandable to > 1bn Blue, anthracite Set bookmark or start and stop recording Integrated sensor: Working range: Accuracy: Measurement /  storage rate: Power supply: MSR 165 with external sensors Operating conditions: Storage conditions: Standards: Up to 1600 /s (±15%) Lithium-polymer battery (900 mAh), rechargeable via USB connection, recording period up to 6 months or replaceable batteries (Li-SOCl2, 3.6 V, 2 x 7700 mAh), for recordings up to 5 years Free Setup, Reader, Viewer- & Online software (Windows XP/Vista/7/8/10) USB Temperature -20…+65 °C •  Temperature +5…+45° C (ideal storage condition for the battery) • 10…95% re

Open the catalog to page 1
MSR165 - 2

Measurement parameters for the additional sensors (internal and external) In addition to 3-axis acceleration you can also simultaneously measure temperature, humidity, pressure and/or light using the MSR 165 data logger. There is a choice between internal and external sensors for these additional measurement parameters. The external sensors are available with cable lengths of 0.20 m, 1.0 m and 1.6 m. Measured parameters Additional analogue inputs for connecting third-party sensors MSR 165 Analogue Inputs Inc. alarm output and input for starting 4 analogue inputs with freely selecta-and...

Open the catalog to page 2
MSR165 - 3

Headquarter Switzerland: Pewatron AG Thurgauerstrasse 66 CH-8050 Zurich Phone +41 44 877 35 00 info@pewatron.com Office Germany: Pewatron Deutschland GmbH EdisonstraEe 16 D-85716 UnterschleiEheim Phone +49 89 374 288 87-0 info.de@pewatron.com PEWATRON 5ENS0R5 • POWER SOLUTIONS We are here for you. Addresses and Contacts. Sales Germany & Austria Postcode 00000 - 31999 Postcode 38000 - 39999 Postcode 80000 - 99999 Austria Kurt Stritzelberger Phone + 49 89 260 52 80 Mobile + 49 171 803 41 35 kurt.stritzelberger@pewatron.com Geometrical sensors Sensor elements Thorsten Ravagni Phone +49 60 479...

Open the catalog to page 3

All Angst+Pfister Sensors and Power AG catalogs and technical brochures

  1. PFLOW Series

    5 Pages

  2. PZA-MC25-N/P

    2 Pages

  3. PEWA100

    9 Pages

  4. POB-30 series

    11 Pages

  5. RFP-M8M4-5A

    5 Pages

  6. RFP-M5M3-3A

    4 Pages

  7. RFP-M2M3-3A

    4 Pages

  8. RFP-M1M3-3A

    4 Pages

  9. NCL CL1 01

    4 Pages

  10. IRL RGB 01

    4 Pages

  11. IRL CL2 01

    4 Pages

  12. MSR385WD

    3 Pages

  13. MSR145WD

    3 Pages

  14. MSR 145

    3 Pages

  15. M2029

    3 Pages

  16. CRM102.1

    33 Pages

  17. CRM200

    39 Pages

  18. CRM100

    37 Pages

  19. FPM

    4 Pages

  20. FGN

    4 Pages

  21. FPN

    4 Pages

  22. PBM220 series

    15 Pages

  23. APB2Series

    5 Pages

  24. AP4Series

    5 Pages

  25. AP2Series

    5 Pages

  26. PPCP3-M1

    10 Pages

  27. AG4Series

    6 Pages

  28. AG2Series

    5 Pages

  29. GST220A

    4 Pages

  30. GSM40B

    6 Pages

  31. GSM36B

    4 Pages

  32. GSC25E

    5 Pages

  33. TDR-480

    5 Pages

  34. GC120

    4 Pages

  35. HDR-30

    5 Pages

  36. GSM220A

    6 Pages

  37. EPP-400

    5 Pages

  38. ENP-120

    5 Pages

  39. ENC-120

    6 Pages

  40. ATX-100

    4 Pages

  41. RPS-200

    7 Pages

  42. APBR30X75

    2 Pages

  43. APBR30X60

    2 Pages

  44. PSB54/16

    2 Pages

  45. PSB54/14

    2 Pages

  46. PSB36T/16

    2 Pages

  47. PSB35T/12

    2 Pages

  48. PSB25T/16

    2 Pages

  49. PSB25T/12

    2 Pages

  50. PSB21/12

    2 Pages

  51. PSB 21

    2 Pages

  52. AD-Series

    16 Pages

  53. DMU11

    3 Pages

  54. DMU30-01

    25 Pages

  55. DMU30

    3 Pages

  56. DCW12

    2 Pages

  57. DCW05

    2 Pages

  58. 7S Series

    3 Pages

  59. Model CE36M

    3 Pages

  60. EX 80 A

    3 Pages

  61. UFO

    3 Pages

  62. UFO-M2

    3 Pages

  63. GC30E

    3 Pages

  64. RPS-400

    11 Pages

  65. GC 330

    4 Pages

  66. EL30

    3 Pages

  67. EA PROFIBUS

    7 Pages

  68. EAMW

    3 Pages

  69. AAM58

    4 Pages

  70. EAM36

    3 Pages

  71. CARBONOXY25

    2 Pages

  72. CARBONDIO-%

    2 Pages

  73. FCX-MC25-CH

    3 Pages

  74. FCX-MC05-CH

    3 Pages

  75. FCX-TR0025

    4 Pages

  76. LP-10HA

    3 Pages

  77. FCX-UC-CH

    9 Pages

  78. 901.1-EX

    5 Pages

  79. FC22

    3 Pages

  80. MILLINEWTON

    3 Pages

  81. 901.1

    5 Pages

  82. HX-EP

    6 Pages

  83. Tailor-made

    10 Pages

  84. RAZTEC

    13 Pages

  85. 930 Climair

    5 Pages