HX-EP - 1

HX-EP SERIES DIGITAL OUTPUT Utilizing an incremental encoder as the sensor, the HX-EP series position transducer provides a two channel square wave current sinking output signal in quadrature. The standard output is a single-ended TTL compatible square. The resolution values shown in the specifications table indicate resolution for times 1 counting mode where a count is registered for one up transition in channel A. With interface electronics capable of times 2 or times 4 counting mode, a true resolutional increase of 2 or 4 may be obtained. For example, the HX-EP-50 has a resolution of approximately .004" per count in times 1 counting mode whereas the resolution is approximately .001" per count in times 4 counting mode. The actual resolution of a HX-EP transducer differs from unit to unit because of tolerances associated with the wire rope diameter and the capstan upon which the wire rope winds. The nylon jacketed wire rope option will have the effect of slightly reducing the resolution. Linearity and repeatability remain independent of resolution. In applications where the output count is interpreted as a percentage of total travel, resolutional differences from unit to unit are not critical. However, in applications where the digital output is to be interfaced to a digital display to give an output in engineering units, the calibration constant supplied with the transducer may be used to calculate a suitable scale multiplier to produce the correct engineering units. Alternative outputs shown in the Electrical Outputs table below are available to facilitate interfacing to a variety of different types of equipment. ALL RANGES GREATER THAN 100” ELECTRICAL OUTPUT For electrical output description, waveform and wiring, See Standard Series Supplemental Data, TABLE 8. FOOTNOTES TO SPECIFICATIONS 1. Supplemental Data section located at end of HX Series pages. 2. The resolution shown is a calculated number based upon the capstan diameter, wire rope diameter and line count of the encoding device. The tolerance on the resolution accounts for resolutional differences from unit to unit due to manufacturing tolerances on the capstan and wire rope. In practice, the output count in a given unit of travel is an integer. MODEL NUMBER CONFIGURATION Basic Configuration (See Supplemental Data, Table 12) WIRE ROPE EXIT DIRECTION U se Number designators shown ELECTRICAL OUTPUT INGRESS PROTECTION For Description See Supplemental Data, TABLE 8 NOTES FOR OPTION BOXES 7 , 8, and 9 (NEMA 4): Transducer equipped with body mounted connector and with or without mating connector. Mating connector with electrical cable available separately as part number 10119-xM where ‘x’ is length of electrical cable in meters. IP-68–NEMA 6 CABLE MOUNTED CONNECTOR (NEMA 6): Transducer equipped with bulkhead fitting and length of electrical cable. Remote end of electrical cable may be outfitted with water proof connector. Mating connector with electrical cable available separately as part number 10424-xM where ‘x’ is length of electrical cable in meters.

Open the catalog to page 1
HX-EP - 2

SUPPLEMENTAL DATA OPTION DESCRIPTIONS OPTION OPTION DESIGNATOR Replaces standard stainless steel wire rope with Ø.018 nylon jacketed wire rope. This option increases wire rope life dramatically but may increase non-linearity by as much as ±.05% of full scale. Replaces standard stainless steel wire rope with Ø.037 nylon jacketed wire rope. WIRE ROPE NYLON JACKETED WIRE ROPE RANGES TO 80” ONLY NYLON JACKETED WIRE ROPE RANGES 100" TO 500" ONLY WIRE ROPE EXIT DIRECTION ALTERNATE WIRE ROPE EXIT RANGES TO 80” (2.0 m) (dimensions in brackets are millimeters) ALTERNATE WIRE ROPE EXIT RANGES 100”...

Open the catalog to page 2
HX-EP - 3

ADDITIONAL OPTIONS EP, HX-EP SERIES OPTIONAL ELECTRICAL OUTPUTS OUTPUT DESCRIPTION 5 VDCTTL compatible open collector current sinking output. Two channels with optional index channel available. 11 is same as Option 10 but adds the index (Z) channel. Current sinking output with 10KQ internal pullup resistors 8 to 28 VDC input voltage. 51 is same as Option 50 but adds the 5 VDC Push-Pull Differential Line Drive Push-Pull, current sourcing and current sinking output. 5 VDC input voltage. Output is compliant with requirements of TIA/EIA- 422-B. 31 is same as Option 30 but adds the index (Z)...

Open the catalog to page 3
HX-EP - 4

SUPPLEMENTAL DATA MECHANICAL SPECIFICATIONS Stainless Steel & Anodized Aluminum Housing High Impact, Corrosion Resistant Thermoplastic Housings 1. With 1K ohm potentiometer, wire rope misalignment 2° maximum at full stroke, relatively dust free environment, nylon jacketed wire rope on units with ranges 80" and less. Use value from this column to indicate over- Check mark indicates available measurement range Product Photo Specifications subject to change without notice Supporting your great ideas a member of the Angst + Pfister Group

Open the catalog to page 4
HX-EP - 5

SUPPLEMENTAL DATA DIMENSIONAL INFORMATION HX SERIES RANGES 80" (2 m) OR LESS HX SERIES RANGES GREATER THAN 80" (2 m) JN MODELS WITH ZERO AND SPAN :DNTREILS, REMOVE SELF SEALING SCREWS TE ACCESS ADJUSTMENT ^MOUNTING SURFACE [dimensions in brackets are millimeters] 1. Transducer mounts with 0.25 or M6 socket head cap bolts EN MEDELS WITH ZERE AND SPAN CONTROLS, REMOVE SELF SEALING SCREWS TE ACCESS ADJUSTMENT 1. Transducer mounts with 0.50 or M12 socket head cap bolts, 2. Dimension "C" is the cable offset that occurs as the cable is extended from the transducer. For "C" in inches, C = .0016 x...

Open the catalog to page 5
HX-EP - 6

We are here for you. Addresses and Contacts Sales Switzerland & Liechtenstein Sales International Key Accounts Matthias Rüegg Ruhbergstrasse 32 CH-9230 Flawil Peter Felder Thurgauerstrasse 66 CH-8052 Zürich Sales Austria Sales Germany Postcode 10000 –59999 Postcode 80000 –99999 Kurt Stritzelberger Neumarkter Str. 86a D-81673 Munich Dieter Hirthe Auf der Entenweide 4 69502 Hemsbach Kurt Stritzelberger Neumarkter Str. 86a D-81673 Munich Sales Other Countries / Product Management Sensors Power Supplies Physical Sensors Data Acquisition DC-DC Converters Switching Power Supplies DC-AC Inverters...

Open the catalog to page 6

All Angst+Pfister Sensors and Power AG catalogs and technical brochures

  1. PFLOW Series

    5 Pages

  2. PZA-MC25-N/P

    2 Pages

  3. PEWA100

    9 Pages

  4. POB-30 series

    11 Pages

  5. RFP-M8M4-5A

    5 Pages

  6. RFP-M5M3-3A

    4 Pages

  7. RFP-M2M3-3A

    4 Pages

  8. RFP-M1M3-3A

    4 Pages

  9. NCL CL1 01

    4 Pages

  10. IRL RGB 01

    4 Pages

  11. IRL CL2 01

    4 Pages

  12. MSR385WD

    3 Pages

  13. MSR145WD

    3 Pages

  14. MSR 145

    3 Pages

  15. M2029

    3 Pages

  16. MSR165

    3 Pages

  17. CRM102.1

    33 Pages

  18. CRM200

    39 Pages

  19. CRM100

    37 Pages

  20. FPM

    4 Pages

  21. FGN

    4 Pages

  22. FPN

    4 Pages

  23. PBM220 series

    15 Pages

  24. APB2Series

    5 Pages

  25. AP4Series

    5 Pages

  26. AP2Series

    5 Pages

  27. PPCP3-M1

    10 Pages

  28. AG4Series

    6 Pages

  29. AG2Series

    5 Pages

  30. GST220A

    4 Pages

  31. GSM40B

    6 Pages

  32. GSM36B

    4 Pages

  33. GSC25E

    5 Pages

  34. TDR-480

    5 Pages

  35. GC120

    4 Pages

  36. HDR-30

    5 Pages

  37. GSM220A

    6 Pages

  38. EPP-400

    5 Pages

  39. ENP-120

    5 Pages

  40. ENC-120

    6 Pages

  41. ATX-100

    4 Pages

  42. RPS-200

    7 Pages

  43. APBR30X75

    2 Pages

  44. APBR30X60

    2 Pages

  45. PSB54/16

    2 Pages

  46. PSB54/14

    2 Pages

  47. PSB36T/16

    2 Pages

  48. PSB35T/12

    2 Pages

  49. PSB25T/16

    2 Pages

  50. PSB25T/12

    2 Pages

  51. PSB21/12

    2 Pages

  52. PSB 21

    2 Pages

  53. AD-Series

    16 Pages

  54. DMU11

    3 Pages

  55. DMU30-01

    25 Pages

  56. DMU30

    3 Pages

  57. DCW12

    2 Pages

  58. DCW05

    2 Pages

  59. 7S Series

    3 Pages

  60. Model CE36M

    3 Pages

  61. EX 80 A

    3 Pages

  62. UFO

    3 Pages

  63. UFO-M2

    3 Pages

  64. GC30E

    3 Pages

  65. RPS-400

    11 Pages

  66. GC 330

    4 Pages

  67. EL30

    3 Pages

  68. EA PROFIBUS

    7 Pages

  69. EAMW

    3 Pages

  70. AAM58

    4 Pages

  71. EAM36

    3 Pages

  72. CARBONOXY25

    2 Pages

  73. CARBONDIO-%

    2 Pages

  74. FCX-MC25-CH

    3 Pages

  75. FCX-MC05-CH

    3 Pages

  76. FCX-TR0025

    4 Pages

  77. LP-10HA

    3 Pages

  78. FCX-UC-CH

    9 Pages

  79. 901.1-EX

    5 Pages

  80. FC22

    3 Pages

  81. MILLINEWTON

    3 Pages

  82. 901.1

    5 Pages

  83. Tailor-made

    10 Pages

  84. RAZTEC

    13 Pages

  85. 930 Climair

    5 Pages