DAP-04 series
8Pages

{{requestButtons}}

Catalog excerpts

DAP-04 series - 1

DALI-PWM Signal Converter DAP-04 series SELV EHIC C■ Features ■ Applications • Universal AC input / Full range ( up to 305VAC) • Indoor lighting • Convert DALI signal to PWM signal • Office lighting • 4 DALI addressable output channels • Decorative lighting • Built-in push dim function • InPut signal : DALI or Push dim • Comply with DALI standards (IEC62386-101, 102, 207) Output signal : open collector pWM • PWM active high or active low selectable by jumper signal • Linear or logarithm dimming curve selectable (comply with IEC62386-207) • Dimming range : 1 ~ 100% • Built-in relay for ON/OFF control of LED power supply • Fully isolated plastic case • Class n power unit, no FG • IP20 design • Power consumption < 0.5W (Note.1) • 3 years warranty ■ Description DAP-04 series is a "DALI signal to PWM signal "converter, spec ifically working with the MEAN WELL AC/DC LED power supplies with 3-in-1 dimming function (1~10V/ PWM / Resistance). ■ Order Name Encoding DAP - 04 -f Blank : Standard model with ACT-HI function S01 : Standard model with 4 or 1 DALI address selectable function (Note.2) Number of output channels Series name Competitive sensor Et power supply so

Open the catalog to page 1
DAP-04 series - 2

DALI-PWM Signal Converter DAP-04 series SPECIFICATION MODEL Competitive sensor Et power supply solutions worldwide

Open the catalog to page 2
DAP-04 series - 3

DALI-PWM Signal Converter DAP-04 series ■ Block Diagram PUSH dim(primary side) • Maximum length of the cable, from push button to last driver, is 20 meter. • Factory default dimming setting : 100%. • Every long pushing action will change the dimming direction. DALI interface(primary side) • DALI protocol including 16 groups and 64 addresses. Competitive sensor & power supply solutions worldwide

Open the catalog to page 3
DAP-04 series - 4

DALI-PWM Signal Converter Connection of Dimming Operation DALI Dimming solution : DAP-04 series with MEAN WELL's LED power supply MEAN WELL's AC/DC LED PSU V+ VAD/DC LED PSU 1 DIM+ AC/N DIM- V+ VAD/DC LED PSU 4 DIM+ AC/N DIMAC/L DALI Bus DALI controller DAP-04 series (DALI-PWM signal converter) ※Note: 1 . Choose a suitable cable for connecting the DAP-04 series and DALI controller and make sure the maximum voltage drop between these two units should not be higher than 2V. (Maximum cable length for 1.5mm 2 cables is 300m.) 2.Only DIM 1 has output PWM dimming signal for DAP-04-S01 with 1 DALI...

Open the catalog to page 4
DAP-04 series - 5

DALI-PWM Signal Converter Dimming with LED PSU ON/OFF The DAP-04 series is equipped with a relay that can be used to turn ON/OFF MEAN WELL LED PSUs. The relay is in the closed position when the DIM1 generates dimming signal; the relay is in the open position when there is no output signal on the DIM1. MEAN WELL AC/DC LED PSU VLED Lighting Fixture DIM+ DAP-04 series (DALI-PWM signal converter ) An additional magnetic switch is needed when the total input current of the selected LED PSUs is higher than 8A or used with LED PSUs whose inrush current is greater than 50A, please refer to the...

Open the catalog to page 5
DAP-04 series - 6

DALI-PWM Signal Converter SYNCHRONIZATION OPERATION DAP-04 series provides 4-channel outputs; every channel controls up to 20 units of MEAN WELL LED PSU. The 4 channels can thus control up to 80 units of MEAN WELL LED PSU. (Note. 1) The dimming percentage of the MEAN WELL LED PSUs controlled by the same channel of DAP-04 is the same. The dimming percentage per DAP-04 series channel can be controlled independently. T he maximum allowable voltage drop between the DAP-04 series and LED PSUs should not be higher than 0.5V. Dimmingable DAP-04 series (DALI-PWM signal converter) Note. 1 .Light...

Open the catalog to page 6
DAP-04 series - 7

DALI-PWM Signal Converter DAP-04 series I Mechanical SpeCification Case No.DAP-04 Unit:mm Competitive sensor & power supply solutions worldwide

Open the catalog to page 7
DAP-04 series - 8

Headquarter Switzerland: Pewatron AG Thurgauerstrasse 66 CH-8050 Zurich Phone +41 44 877 35 00 info@pewatron.com Office Germany: Pewatron Deutschland GmbH EdisonstraEe 16 D-85716 UnterschleiEheim Phone +49 89 374 288 87-0 info.de@pewatron.com PEWATRON 5ENS0R5 • POWER SOLUTIONS We are here for you. Addresses and Contacts. Sales Germany & Austria Postcode 00000 - 31999 Postcode 38000 - 39999 Postcode 80000 - 99999 Austria Kurt Stritzelberger Phone + 49 89 260 52 80 Mobile + 49 171 803 41 35 kurt.stritzelberger@pewatron.com Geometrical sensors Sensor elements Thorsten Ravagni Phone +49 60 479...

Open the catalog to page 8

All Angst+Pfister Sensors and Power AG catalogs and technical brochures

  1. PFLOW Series

    5 Pages

  2. PZA-MC25-N/P

    2 Pages

  3. PEWA100

    9 Pages

  4. POB-30 series

    11 Pages

  5. RFP-M8M4-5A

    5 Pages

  6. RFP-M5M3-3A

    4 Pages

  7. RFP-M2M3-3A

    4 Pages

  8. RFP-M1M3-3A

    4 Pages

  9. NCL CL1 01

    4 Pages

  10. IRL RGB 01

    4 Pages

  11. IRL CL2 01

    4 Pages

  12. MSR385WD

    3 Pages

  13. MSR145WD

    3 Pages

  14. MSR 145

    3 Pages

  15. M2029

    3 Pages

  16. MSR165

    3 Pages

  17. CRM102.1

    33 Pages

  18. CRM200

    39 Pages

  19. CRM100

    37 Pages

  20. FPM

    4 Pages

  21. FGN

    4 Pages

  22. FPN

    4 Pages

  23. PBM220 series

    15 Pages

  24. APB2Series

    5 Pages

  25. AP4Series

    5 Pages

  26. AP2Series

    5 Pages

  27. PPCP3-M1

    10 Pages

  28. AG4Series

    6 Pages

  29. AG2Series

    5 Pages

  30. GST220A

    4 Pages

  31. GSM40B

    6 Pages

  32. GSM36B

    4 Pages

  33. GSC25E

    5 Pages

  34. TDR-480

    5 Pages

  35. GC120

    4 Pages

  36. HDR-30

    5 Pages

  37. GSM220A

    6 Pages

  38. EPP-400

    5 Pages

  39. ENP-120

    5 Pages

  40. ENC-120

    6 Pages

  41. ATX-100

    4 Pages

  42. RPS-200

    7 Pages

  43. APBR30X75

    2 Pages

  44. APBR30X60

    2 Pages

  45. PSB54/16

    2 Pages

  46. PSB54/14

    2 Pages

  47. PSB36T/16

    2 Pages

  48. PSB35T/12

    2 Pages

  49. PSB25T/16

    2 Pages

  50. PSB25T/12

    2 Pages

  51. PSB21/12

    2 Pages

  52. PSB 21

    2 Pages

  53. AD-Series

    16 Pages

  54. DMU11

    3 Pages

  55. DMU30-01

    25 Pages

  56. DMU30

    3 Pages

  57. DCW12

    2 Pages

  58. DCW05

    2 Pages

  59. 7S Series

    3 Pages

  60. Model CE36M

    3 Pages

  61. EX 80 A

    3 Pages

  62. UFO

    3 Pages

  63. UFO-M2

    3 Pages

  64. GC30E

    3 Pages

  65. RPS-400

    11 Pages

  66. GC 330

    4 Pages

  67. EL30

    3 Pages

  68. EA PROFIBUS

    7 Pages

  69. EAMW

    3 Pages

  70. AAM58

    4 Pages

  71. EAM36

    3 Pages

  72. CARBONOXY25

    2 Pages

  73. CARBONDIO-%

    2 Pages

  74. FCX-MC25-CH

    3 Pages

  75. FCX-MC05-CH

    3 Pages

  76. FCX-TR0025

    4 Pages

  77. LP-10HA

    3 Pages

  78. FCX-UC-CH

    9 Pages

  79. 901.1-EX

    5 Pages

  80. FC22

    3 Pages

  81. MILLINEWTON

    3 Pages

  82. 901.1

    5 Pages

  83. HX-EP

    6 Pages

  84. Tailor-made

    10 Pages

  85. RAZTEC

    13 Pages

  86. 930 Climair

    5 Pages