DIGITAL OUTPUT Solid State Pressure SensorCCD Series - Model 54D FEATURES • DIP or SMD Package • Calibrated Span and Offset • Multi-order Temperature compensation • OWI, I2C or SPI Interface • 3V or 5V Supply • Customized Configuration upon request DESCRIPTION The Series CCD Model 54D is a smart pressure transducer with digital output via 1-wire serial, I2C or SPI interface. Digital compensation of sensor offset, sensitivity, temperature drift and nonlinearity is accomplished in factory via an internal DSP running a correction algorithm with calibration coefficients stored in on-chip EEPROM. A variety of characteristic configuration, including accuracy, sampling rate, temperature compensated range are available to provide simple and ready-to-use solution for a wide rage of application. It can be operated in supply voltage of 2.7 to 5.5 V, and can be extended to 30V with an external JFET. The Series CCD is available for pressure range from 0.15 psi to 150 psi. Special configuration as low as 2.5 mbar is also applicable. Please contact factory for detail. Competitive sensor & power supply solutions worldwide PEWATRON
Open the catalog to page 1Ordering Information Series CCD 54 Digital 54D L XXX G - X 0 X X Option 0: No special reguest Series Supply Voltage Blank = 4.75 to 5.25 V L = 2.75 to 3.33 V Type of Pressure G: Gage (Port B only) H: Gage (Dual Port) A: Absolute (Port A only) D: Differential I: Negative Gage (Port B only) Leading Direction Pressure range Medium Pressure 003 = 0 ~ 3 psi 005 = 0 ~ 5 psi 007 = 0 ~ 7 psi 015 = 0 ~ 15 psi 030 = 0 ~ 30 psi 050 = 0 ~ 50 psi 100 = 0 ~ 100 psi 150 = 0 ~ 150 psi Low Pressure L15 = 0 ~ 0.15 psi L30 = 0 ~ 0.3 psi L50 = 0 ~ 0.5 psi L70 = 0 ~ 0.7 psi Ultra-low Pressure L03 = 0 ~ 2.5 mbar L07...
Open the catalog to page 2CharacteristicsUnless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH Parameters 1. Supply 3 V or 5 V must be ordered separately. 5. 1.2X for 150 psi 2. Smaller range and other units are also available for ordering 6. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 3. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 7. Output is ratiometric to supply voltage 4. For differential pressure, offset = 2000 hex, FS = 666/3999 8. Output load resistance to Vss or Vdd: 2.5KQ (min), 10KQ (typ) PORT DIFF...
Open the catalog to page 3CCD54D 1610-21567-0038-E-0913 CharacteristicsUnless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH Parameters 1. Supply 3 V or 5 V must be ordered separately. 5. Over-pressure will vary on different range 2. Smaller range and other units are also available for ordering 6. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 3. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 8. Output load resistance to Vss or Vdd: 2.5KQ (min), 10KQ (typ) 4. For differential pressure, offset = 2000 hex, FS = 666/3999 9. Zeroing...
Open the catalog to page 4Characteristics Unless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH NOTES: 1. Supply 3V or 5V must be ordered separately. 6. Power up to output 2. Smaller range and other units are also available for ordering 7. Over-pressure will vary on different range 3. Vary with sensor configuration. Refer to individual data sheet. 8. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 4. Accuracy includes N°L, hysterisis, TCS and TCO over 0/50°C, BFSL definition 9. Output load resistance to Vss or Vdd: 2.5KO (min), 10KO (typ) 5. For differential pressure,...
Open the catalog to page 5CharacteristicsUnless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH Parameters 1. Supply 3V or 5V must be ordered separately. 5. Minimum pull-up on SDA and SCL is 1KQ 2. Smaller range and other units are also available for ordering 6. 1.2X for 150 psi 3. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 7. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 4. For differential pressure, offset = 2000 hex, FS = 666/3999 9. The factory setting for I2C slave address is 0x28 PORT DIFF 1 PORT GAGE 1 PORT ABS NOTE: 1. Port...
Open the catalog to page 6CharacteristicsUnless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH Parameters 1. Supply 3V or 5V must be ordered separately. 5. Minimum pull-up on SDA and SCL is 1KQ 2. Smaller range and other units are also available for ordering 6. Over-pressure will vary on different range 3. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 7. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 4. For differential pressure, offset = 2000 hex, FS = 666/3999 8. The factory setting for I2C slave address is 0x28...
Open the catalog to page 7CharacteristicsUnless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH Parameters 1. Supply 3V or 5V must be ordered separately. 6. Minimum pull-up on SDA and SCL is 1KQ 2. Custom range and other units are available for ordering 7. Over-pressure may vary from pressure ranges 3. May vary with sensor configuration 8. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 4. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 9. The factory setting for I2C slave address is 0x28 5. For differential pressure, offset =...
Open the catalog to page 8Communication Interface Manchester codes by a transition at the cell boundary are used to represent the binary values of pressure and temperature. Bit Encoding Data Cell 50% duty cycle used to set up strobe time Read Operation There are two modes (DPT digital pressure output with temperature, and DTO digital pressure out only) available for the output of transducer. For DPO mode, the transducer first transmits the high byte of pressure data followed by the low byte. The pressure data is 14-bits in resolution, so the upper two bits of the high byte are always zero padded. There is a half stop...
Open the catalog to page 94 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
5 Pages
16 Pages
3 Pages
14 Pages
3 Pages
6 Pages
7 Pages
2 Pages
9 Pages
5 Pages
5 Pages
6 Pages
6 Pages
9 Pages
8 Pages
11 Pages
9 Pages
5 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
33 Pages
39 Pages
37 Pages
4 Pages
4 Pages
4 Pages
14 Pages
15 Pages
14 Pages
11 Pages
7 Pages
5 Pages
5 Pages
5 Pages
6 Pages
10 Pages
6 Pages
5 Pages
11 Pages
4 Pages
6 Pages
4 Pages
5 Pages
5 Pages
4 Pages
5 Pages
6 Pages
5 Pages
5 Pages
6 Pages
4 Pages
7 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
16 Pages
3 Pages
5 Pages
25 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
3 Pages
11 Pages
16 Pages
2 Pages
12 Pages
6 Pages
5 Pages
3 Pages
3 Pages
2 Pages
3 Pages
3 Pages
11 Pages
4 Pages
3 Pages
7 Pages
3 Pages
4 Pages
3 Pages
2 Pages
2 Pages
14 Pages
3 Pages
3 Pages
4 Pages
3 Pages
9 Pages
5 Pages
3 Pages
3 Pages
5 Pages
5 Pages
6 Pages
5 Pages
6 Pages
10 Pages
13 Pages
3 Pages
5 Pages
5 Pages
5 Pages
4 Pages
5 Pages
3 Pages
8 Pages