CCD Series – Model 54D
20Pages

{{requestButtons}}

Catalog excerpts

CCD Series – Model 54D - 1

DIGITAL OUTPUT Solid State Pressure SensorCCD Series - Model 54D FEATURES • DIP or SMD Package • Calibrated Span and Offset • Multi-order Temperature compensation • OWI, I2C or SPI Interface • 3V or 5V Supply • Customized Configuration upon request DESCRIPTION The Series CCD Model 54D is a smart pressure transducer with digital output via 1-wire serial, I2C or SPI interface. Digital compensation of sensor offset, sensitivity, temperature drift and nonlinearity is accomplished in factory via an internal DSP running a correction algorithm with calibration coefficients stored in on-chip EEPROM. A variety of characteristic configuration, including accuracy, sampling rate, temperature compensated range are available to provide simple and ready-to-use solution for a wide rage of application. It can be operated in supply voltage of 2.7 to 5.5 V, and can be extended to 30V with an external JFET. The Series CCD is available for pressure range from 0.15 psi to 150 psi. Special configuration as low as 2.5 mbar is also applicable. Please contact factory for detail. Competitive sensor & power supply solutions worldwide PEWATRON

Open the catalog to page 1
CCD Series – Model 54D - 2

Ordering Information Series CCD 54 Digital 54D L XXX G - X 0 X X Option 0: No special reguest Series Supply Voltage Blank = 4.75 to 5.25 V L = 2.75 to 3.33 V Type of Pressure G: Gage (Port B only) H: Gage (Dual Port) A: Absolute (Port A only) D: Differential I: Negative Gage (Port B only) Leading Direction Pressure range Medium Pressure 003 = 0 ~ 3 psi 005 = 0 ~ 5 psi 007 = 0 ~ 7 psi 015 = 0 ~ 15 psi 030 = 0 ~ 30 psi 050 = 0 ~ 50 psi 100 = 0 ~ 100 psi 150 = 0 ~ 150 psi Low Pressure L15 = 0 ~ 0.15 psi L30 = 0 ~ 0.3 psi L50 = 0 ~ 0.5 psi L70 = 0 ~ 0.7 psi Ultra-low Pressure L03 = 0 ~ 2.5...

Open the catalog to page 2
CCD Series – Model 54D - 3

CharacteristicsUnless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH Parameters 1. Supply 3 V or 5 V must be ordered separately. 5. 1.2X for 150 psi 2. Smaller range and other units are also available for ordering 6. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 3. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 7. Output is ratiometric to supply voltage 4. For differential pressure, offset = 2000 hex, FS = 666/3999 8. Output load resistance to Vss or Vdd: 2.5KQ (min), 10KQ (typ) PORT...

Open the catalog to page 3
CCD Series – Model 54D - 4

CCD54D 1610-21567-0038-E-0913 CharacteristicsUnless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH Parameters 1. Supply 3 V or 5 V must be ordered separately. 5. Over-pressure will vary on different range 2. Smaller range and other units are also available for ordering 6. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 3. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 8. Output load resistance to Vss or Vdd: 2.5KQ (min), 10KQ (typ) 4. For differential pressure, offset = 2000 hex, FS =...

Open the catalog to page 4
CCD Series – Model 54D - 5

Characteristics Unless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH NOTES: 1. Supply 3V or 5V must be ordered separately. 6. Power up to output 2. Smaller range and other units are also available for ordering 7. Over-pressure will vary on different range 3. Vary with sensor configuration. Refer to individual data sheet. 8. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 4. Accuracy includes N°L, hysterisis, TCS and TCO over 0/50°C, BFSL definition 9. Output load resistance to Vss or Vdd: 2.5KO (min), 10KO (typ) 5. For differential...

Open the catalog to page 5
CCD Series – Model 54D - 6

CharacteristicsUnless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH Parameters 1. Supply 3V or 5V must be ordered separately. 5. Minimum pull-up on SDA and SCL is 1KQ 2. Smaller range and other units are also available for ordering 6. 1.2X for 150 psi 3. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 7. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 4. For differential pressure, offset = 2000 hex, FS = 666/3999 9. The factory setting for I2C slave address is 0x28 PORT DIFF 1 PORT GAGE 1 PORT ABS NOTE: 1....

Open the catalog to page 6
CCD Series – Model 54D - 7

CharacteristicsUnless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH Parameters 1. Supply 3V or 5V must be ordered separately. 5. Minimum pull-up on SDA and SCL is 1KQ 2. Smaller range and other units are also available for ordering 6. Over-pressure will vary on different range 3. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 7. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 4. For differential pressure, offset = 2000 hex, FS = 666/3999 8. The factory setting for I2C slave address...

Open the catalog to page 7
CCD Series – Model 54D - 8

CharacteristicsUnless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH Parameters 1. Supply 3V or 5V must be ordered separately. 6. Minimum pull-up on SDA and SCL is 1KQ 2. Custom range and other units are available for ordering 7. Over-pressure may vary from pressure ranges 3. May vary with sensor configuration 8. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 4. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 9. The factory setting for I2C slave address is 0x28 5. For differential pressure, offset...

Open the catalog to page 8
CCD Series – Model 54D - 9

Communication Interface Manchester codes by a transition at the cell boundary are used to represent the binary values of pressure and temperature. Bit Encoding Data Cell 50% duty cycle used to set up strobe time Read Operation There are two modes (DPT digital pressure output with temperature, and DTO digital pressure out only) available for the output of transducer. For DPO mode, the transducer first transmits the high byte of pressure data followed by the low byte. The pressure data is 14-bits in resolution, so the upper two bits of the high byte are always zero padded. There is a half...

Open the catalog to page 9
CCD Series – Model 54D - 10

Timing The baud rate (transmission frequency) of the Manchester coded bit stream is determined during factory calibration and depends on the update rate and thus response time that the customer specifies for the transducer. If no response time is specified by the customer the default response time of 5ms (200Hz) will be selected. There are a total of 4 different update rates listed below. Using the two faster update rates will result in the baud rate being 32kHz and the two slower update rates will result in the baud rate being set to 8kHz. Hints for Writing Firmware: The Baud rates (8kHz...

Open the catalog to page 10

All Angst+Pfister Sensors and Power AG catalogs and technical brochures

  1. PFLOW Series

    5 Pages

  2. PZA-MC25-N/P

    2 Pages

  3. PEWA100

    9 Pages

  4. POB-30 series

    11 Pages

  5. RFP-M8M4-5A

    5 Pages

  6. RFP-M5M3-3A

    4 Pages

  7. RFP-M2M3-3A

    4 Pages

  8. RFP-M1M3-3A

    4 Pages

  9. NCL CL1 01

    4 Pages

  10. IRL RGB 01

    4 Pages

  11. IRL CL2 01

    4 Pages

  12. MSR385WD

    3 Pages

  13. MSR145WD

    3 Pages

  14. MSR 145

    3 Pages

  15. M2029

    3 Pages

  16. MSR165

    3 Pages

  17. CRM102.1

    33 Pages

  18. CRM200

    39 Pages

  19. CRM100

    37 Pages

  20. FPM

    4 Pages

  21. FGN

    4 Pages

  22. FPN

    4 Pages

  23. PBM220 series

    15 Pages

  24. APB2Series

    5 Pages

  25. AP4Series

    5 Pages

  26. AP2Series

    5 Pages

  27. PPCP3-M1

    10 Pages

  28. AG4Series

    6 Pages

  29. AG2Series

    5 Pages

  30. GST220A

    4 Pages

  31. GSM40B

    6 Pages

  32. GSM36B

    4 Pages

  33. GSC25E

    5 Pages

  34. TDR-480

    5 Pages

  35. GC120

    4 Pages

  36. HDR-30

    5 Pages

  37. GSM220A

    6 Pages

  38. EPP-400

    5 Pages

  39. ENP-120

    5 Pages

  40. ENC-120

    6 Pages

  41. ATX-100

    4 Pages

  42. RPS-200

    7 Pages

  43. APBR30X75

    2 Pages

  44. APBR30X60

    2 Pages

  45. PSB54/16

    2 Pages

  46. PSB54/14

    2 Pages

  47. PSB36T/16

    2 Pages

  48. PSB35T/12

    2 Pages

  49. PSB25T/16

    2 Pages

  50. PSB25T/12

    2 Pages

  51. PSB21/12

    2 Pages

  52. PSB 21

    2 Pages

  53. AD-Series

    16 Pages

  54. DMU11

    3 Pages

  55. DMU30-01

    25 Pages

  56. DMU30

    3 Pages

  57. DCW12

    2 Pages

  58. DCW05

    2 Pages

  59. 7S Series

    3 Pages

  60. Model CE36M

    3 Pages

  61. EX 80 A

    3 Pages

  62. UFO

    3 Pages

  63. UFO-M2

    3 Pages

  64. GC30E

    3 Pages

  65. RPS-400

    11 Pages

  66. GC 330

    4 Pages

  67. EL30

    3 Pages

  68. EA PROFIBUS

    7 Pages

  69. EAMW

    3 Pages

  70. AAM58

    4 Pages

  71. EAM36

    3 Pages

  72. CARBONOXY25

    2 Pages

  73. CARBONDIO-%

    2 Pages

  74. FCX-MC25-CH

    3 Pages

  75. FCX-MC05-CH

    3 Pages

  76. FCX-TR0025

    4 Pages

  77. LP-10HA

    3 Pages

  78. FCX-UC-CH

    9 Pages

  79. 901.1-EX

    5 Pages

  80. FC22

    3 Pages

  81. MILLINEWTON

    3 Pages

  82. 901.1

    5 Pages

  83. HX-EP

    6 Pages

  84. Tailor-made

    10 Pages

  85. RAZTEC

    13 Pages

  86. 930 Climair