ANALOG OUPUT Solid State Pressure SensorCCD Series - Model 53A FEATURES • DIL/SMD Ceramic Package • Calibrated Span and Offset • Multi-order Temperature Compensation • Ratiometric Analog Output • 150 PSI maximum # Customized Configuration Available DESCRIPTION The Series CCD 53A is a smart pressure sensor with calibrated and amplified output. The ceramic hybrid package performs excellent isolation to external stress during operation. Digital compensation of sensor offset, sensitivity, temperature drift and nonlinearity is accomplished in factory via an internal DSP running a correction algorithm with calibration coefficients stored in on-chip EEPROM. A variety of output configuration, including resolution, sampling rate, output interface are available to provide simple and ready-to-use solution for a wide rage of application. The Series CCD 53A is available for pressure range from 0.15 psi to 150 psi. . Special configuration as low as 2.5 mbar is also applicable. Please contact factory for detail. Competitive sensor & power supply solutions worldwide PEWATRON
Open the catalog to page 1Ordering Information Series CCD 53 Analog Option 10: No special reguest 97: Compensated Temp 0~85 degC Other options available upon request. Series Supply Voltage Blank = 4.75 to 5.25 V L = 2.75 to 3.33 V Type of Pressure G: Gage (Port B only) H: Gage (Dual Port) A: Absolute (Port A only) D: Differential (Dual Port) Pressure range Medium Pressure 003 = 0 ~ 3 psi 005 = 0 ~ 5 psi 007 = 0 ~ 7 psi 015 = 0 ~ 15 psi 030 = 0 ~ 30 psi 050 = 0 ~ 50 psi 100 = 0 ~ 100 psi 150 = 0 ~ 150 psi Low Pressure L15 = 0 ~ 0.15 psi L30 = 0 ~ 0.3 psi L50 = 0 ~ 0.5 psi L70 = 0 ~ 0.7 psi Ultra-low Pressure L03 = 0 ~...
Open the catalog to page 2Characteristics Unless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH NOTES: 1. Supply 3V or 5V must be ordered separately. 5. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 2. Smaller range and other units are also available for ordering 6. Output is ratiometric to supply voltage 3. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 7. Output load resistance to Vss or Vdd: 2.5KQ (min), 10KQ (typ) 4. For differential, offset = 2.50V, Span = ±2.00V NOTE: 1. Port B is used for positive differential 2. Port A is used for...
Open the catalog to page 3Characteristics Unless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH 1. Supply 3 V or 5 V must be ordered separately. 5. Over-pressure will vary on different range 2. Smaller range and other units are also available for ordering 6. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 3. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 7. Output is ratiometric to supply voltage 4. For differential, offset = 2.50V, Span = ±2.00V 8. Output load resistance to Vss or Vdd: 2.5KQ (min), 10KQ (typ)...
Open the catalog to page 4Characteristics Unless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH 1. Supply 3 V or 5 V must be ordered separately. 5. Over-pressure will vary on different range 2. Smaller range and other units are also available for ordering 6. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 3. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 7. Output is ratiometric to supply voltage 4. For differential, offset = 2.50V, Span = ±2.00V 8. Output load resistance to Vss or Vdd: 2.5KQ (min), 10KQ (typ)...
Open the catalog to page 5Characteristics Unless otherwise specified, all parameters are measured at 3/5V, 25 °C and 60% RH NOTES: 1. Supply 3V or 5V must be ordered separately. 5. Wetted material: PA, RTV, Epoxy, ceramic, Au, nickel and silicon 2. Smaller range and other units are also available for ordering 6. Output is ratiometric to supply voltage 3. Accuracy includes NOL, hysterisis, TCS and TCO over 0/50°C, BFSL definition 7. Output load resistance to Vss or Vdd: 2.5KQ (min), 10KQ (typ) 4. For differential, offset = 2.50V, Span = ±2.00V NOTE: 1. Port B is used for positive differential 2. Port A is used for...
Open the catalog to page 6Office Germany: Pewatron Deutschland GmbH EdisonstraEe 16 D-85716 UnterschleiEheim Phone +49 89 374 288 87-0 [email protected] PEWATRON 5ENS0R5 • POWER SOLUTIONS Geometrical sensors Sensor elements Thorsten Ravagni Phone +49 60 479 53 627 [email protected] Sales Other Countries / Product Management Pressure Sensors Gas sensors / Gas sensor modules Load cells Dr. Thomas Clausen Phone + 41 44 877 35 13 [email protected] Flow / Level / Medical products Linear position sensors Angle sensors Eric Letsch Phone + 41 44 877 35 14 [email protected] Accelerometers / Level...
Open the catalog to page 74 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
5 Pages
16 Pages
3 Pages
14 Pages
3 Pages
6 Pages
7 Pages
2 Pages
9 Pages
5 Pages
5 Pages
6 Pages
6 Pages
9 Pages
8 Pages
11 Pages
9 Pages
5 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
33 Pages
39 Pages
37 Pages
4 Pages
4 Pages
4 Pages
14 Pages
15 Pages
14 Pages
11 Pages
20 Pages
5 Pages
5 Pages
5 Pages
6 Pages
10 Pages
6 Pages
5 Pages
11 Pages
4 Pages
6 Pages
4 Pages
5 Pages
5 Pages
4 Pages
5 Pages
6 Pages
5 Pages
5 Pages
6 Pages
4 Pages
7 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
16 Pages
3 Pages
5 Pages
25 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
3 Pages
11 Pages
16 Pages
2 Pages
12 Pages
6 Pages
5 Pages
3 Pages
3 Pages
2 Pages
3 Pages
3 Pages
11 Pages
4 Pages
3 Pages
7 Pages
3 Pages
4 Pages
3 Pages
2 Pages
2 Pages
14 Pages
3 Pages
3 Pages
4 Pages
3 Pages
9 Pages
5 Pages
3 Pages
3 Pages
5 Pages
5 Pages
6 Pages
5 Pages
6 Pages
10 Pages
13 Pages
3 Pages
5 Pages
5 Pages
5 Pages
4 Pages
5 Pages
3 Pages
8 Pages