Catalog excerpts
HIPASE SIMPLIFY YOUR SOLUTION
Open the catalog to page 1The new generation of integration ANDRITZ has extensive long-term experience in the areas of excitation, electrical protection, synchronization, and automation of hydropower plants. This has laid the groundwork for development of the new HIPASE platform. HIPASE integrates the specific requirements of various applications in a single unit in powerful fashion so that they are perfectly attuned to one another. The innovative HIPASE product platform was developed especially for use in hydropower plants and includes the following applications: including power supply; application component),...
Open the catalog to page 2integrated engineering The uniform HIPASE Engineering Tool is the optimal tool for easy, efficient configuration of the entire HIPASE platform. It is used for all applications, including excitation, protection, turbine governor, and synchronization. The HIPASE Engineering Tool distinguishes itself through its future-oriented user interface and work-oriented menu structure, providing exceptionally user-friendly operation. It is optimally attuned to users' requirements and needs. All engineering phases of a project can be managed with this tool. In particular, these are: • Parameterization •...
Open the catalog to page 3ExcitationHIPASE-E is a voltage regulator with all limiters, the additional regulators, and gate control set for synchronous single-phase and three-phase machines across a broad frequency range. Instruments Generator Voltage The regulator structure is modular and takes advantage of ANDRITZ'S long experience. The proven control and regulation functions have been re-used and adapted according to the latest requirements of the energy sector. The user can combine the limiters and additional regulators according to plant requirements. The HIPASE-E application component includes the current...
Open the catalog to page 4Electrical protectionHIPASE-P is the optimal solution for state-of-the-art, high-performance generator and transformer protection at various rated frequencies (50 Hz, 60 Hz and 16.7 Hz). A special application component was developed for HIPASE-P, which generates and processes analog signals for special protective functions. Examples of these protective functions are: • Rotor earth fault • Stator earth fault with external frequency shift • Shaft current with adjustable harmonic wave assessment • SFC overcurrent • SFC earth fault • Temperature measurement With the use of the compact housing...
Open the catalog to page 5Turbine regulationHIPASE-T considers the requirements of various turbine types (Francis, Kaplan and Pelton) and the plant due to a scalable, modular application. As essential component of the unit, the turbine governor is responsible for transforming the existing hydraulic energy into electrical energy as efficiently as possible. It guarantees a stable speed for the turbines in no-load and isolated operation, and ensures adherence to the set points in mains operation. The enhanced core algorithm meets the increasing challenges for the turbine governor with respect to frequency and primary...
Open the catalog to page 6SynchronizationHIPASE-S is a state-of-the-art synchronization device for paralleling generators to grids in electrical systems with a frequency of 50 Hz, 60 Hz, and 16.7 Hz. In HIPASE-S there are expanded settings for synchronization, which cover all requirements of modern grids, for example an internal correction of switching groups and the assessment of the rotation direction of systems to be synchronized. HIPASE-S has a lot of persistent RAM for recording and saving long-lasting and many short synchronization processes. With three-phase voltage and current measurement, it is possible to...
Open the catalog to page 7ANDRITZ HYDRO GmbH contact-hydro.acp@andritz.com All data, information, statements, photographs and graphic illustrations in this brochure are without any obligation and raise no liabilities to or form part of any sales contracts of ANDRITZ GROUP or any affiliates for equipment and/or systems referred to herein. All rights reserved. No part of this copyrighted work may be reproduced, modified or distributed in any form or by any means, or stored in any database or retrieval system without the prior written permission of ANDRITZ HYDRO GmbH or its affiliates. Any such unauthorized use for any...
Open the catalog to page 8All ANDRITZ AG catalogs and technical brochures
-
ANDRITZ BELT PRESS CPF-Q
12 Pages
-
GOUDA DRUM DRYER
32 Pages
-
TURBO GENERATOR SERVICE
8 Pages
-
TURBO GENERATORS
12 Pages
-
Image brochure
15 Pages
-
ANDRITZ METALS presentation
26 Pages
-
ANDRITZ SeaSOx brochure
9 Pages
-
ANDRITZ Maerz brochure
11 Pages
-
ANDRITZ belt press
8 Pages
-
Mill sifter
4 Pages
-
Yeast drying
4 Pages
-
PUREVO - the pharma centrifuge
20 Pages
-
Hydrasand
8 Pages
-
Lattomattic
2 Pages
-
Pump solutions for mining
5 Pages
-
Belt Drying System BDC
2 Pages
-
Mining & Minerals
9 Pages
-
F-type decanter centrifuge
4 Pages
-
Torrefaction of biomass
2 Pages
-
Solid bowl decanter D
4 Pages
-
Solid bowl decanter A
3 Pages
-
Power press belt filter
2 Pages
-
Aquaguard
2 Pages
-
Girapac
2 Pages
-
Aqua Screen
2 Pages
-
Aquadrum
2 Pages
-
Air pollution control
13 Pages
-
Aquatic feed
6 Pages