Catalog excerpts
ZL41 Cell sCMOS Easy & Cost-Effective Super-Resolution to ~ 100 nm Key Specifications Live cell imaging Developmental biology Cell and tissue imaging Calcium imaging Productive: up to 22 mm field of view Cell trafficking
Open the catalog to page 1Introduction | Applications | Super-Resolution | Specifications | Product Drawings & Ordering Want Easy Super-Resolution? You got it... ZL41 Cell is compatible with our camera-based realtime super-resolution technology, SRRF-Stream+. ZL41 Cell builds on the strengths of the original Zyla series: high-speed, high-sensitivity and high-resolution imaging performance. ZL41 Cell is perfectly suited to many experiments that push the boundaries of speed and sensitivity. Standard Widefield ZL41 Cell 4.2 provides exceptional sensitivity for live cell imaging with a combination of 82% QE and very low...
Open the catalog to page 2Introduction | Applications | Super-Resolution | Specifications | Product Drawings & Ordering Application and Techniques Quality, Throughput, Performance, Accessibility… 3 High sensitivity & wide dynamic range – quantify very weak and very bright structures with one image. 3 Superb image quality – high resolution and uniform backgrounds for publication quality imaging. 3 Capture everything – large field of view matches that of modern microscopes. Achieve better statistics and higher throughout in high content experiments. 3 Blazingly fast – more and more studies of cell processes require...
Open the catalog to page 3Introduction | Applications | Super-Resolution | Specifications | Product Drawings & Ordering Super-Resolution Ready SRRF-STREAM+ Want to enable fast and easy super-resolution down to 100 nm? Our exclusive camera-based technology enables super-resolution microscopy on conventional modern fluorescence microscopes in real-time. SRRF (Super-Resolution Radial Fluctuations), is a highly effective approach to super-resolution developed by the Henriques research group (Gustafsson et al., 2016). Andor’s unique and exclusive implementation of SRRF-Stream+ allows camera-based real-time...
Open the catalog to page 4Introduction | Applications | Super-Resolution | Specifications | Product Drawings & Ordering Technical Specifications Quantum Efficiency (QE) Curve •3 Model Specific Specifications Sensor type Active pixels (W x H) Front Illuminated Scientific CMOS Front Illuminated Scientific CMOS 200 (100 MHz x 2 sensor halves) 560 (280 MHz x 2 sensor halves) 216 (108 MHz x 2 sensor halves) 540 (270 MHz x 2 sensor halves) Sensor size Pixel readout rate (MHz) Read noise (e-) Median [rms] •2 Maximum Quantum Efficiency •3 Sensor Operating Temperature Air cooled Water cooled Rolling Shutter and True Global...
Open the catalog to page 5Introduction | Applications | Super-Resolution | Specifications | Product Drawings & Ordering Creating The Optimum Product for You Step 1. Camera Type Product Drawings Dimensions in mm [inches] Select the camera type Third-angle projection ZL41 Cell 4.2, 4.2 Megapixel, Rolling shutter, 100 fps, Camera Link, SRRF-Stream+ ready ZL41 Cell 4.2, 4.2 Megapixel, Rolling shutter, 53 fps, USB 3.0, SRRF-Stream+ ready ZL41 Cell 5.5, 5.5 Megapixel, Rolling and Global shutter, 40 fps, USB 3.0 For water cooled or spectroscopy options please enquire with your local sales representative. Select the...
Open the catalog to page 6Order Today Need more information? At Andor we are committed to finding the correct solution for you. With a dedicated team of technical advisors, we are able to offer you one-to-one guidance and technical support on all Andor products. For a full listing of our local sales offices, please see: andor.oxinst.com/contact Our regional headquarters are: Europe Japan Belfast, Northern Ireland Tokyo Phone +44 (28) 9023 7126 Phone +81 (3) 6732 8968 Fax +44 (28) 9031 0792 Fax +81 (3) 6732 8939 North America China Concord, MA, USA Beijing Phone +1 (860) 290 9211 Phone +86 (10) 5884 7900 Fax +1 (860)...
Open the catalog to page 7All Andor Technology catalogs and technical brochures
-
Marana sCMOS
9 Pages
-
MicroPoint 4
9 Pages
-
Sona sCMOS
9 Pages
-
Optistat
11 Pages
-
Multi-Wavelength Imaging
11 Pages
-
BC43
13 Pages
-
andor-kymera-193-specifications
15 Pages
-
andor-dragonfly-specifications
14 Pages
-
Solis-Brochure
6 Pages
-
Spectroscopy-Solutions-Brochure
24 Pages
-
iKon-M/L SO Series
10 Pages
-
iStar CCD and sCMOS
8 Pages
-
Neo 5.5 sCMOS
6 Pages
-
Mechelle 5000
5 Pages
-
Cameras for Astronomy
8 Pages
-
Microspectroscopy Gatefold
8 Pages
-
Spectroscopy Brochure
25 Pages
-
Apogee Alta F9000
5 Pages
-
Apogee Aspen CG230
5 Pages
-
Apogee Aspen CG47
5 Pages
-
Apogee Aspen CG6
5 Pages
-
ApogeeAspen CG9000
5 Pages
-
iXon EMCCD
13 Pages
-
Zyla for Physical Sciences sCMOS
12 Pages
-
iVac OEM 2
2 Pages
-
iKon-M OEM 2-page PV
2 Pages
-
iKon-M X-Ray 2
2 Pages
-
Newton EMCCD
16 Pages
-
iQ Software
12 Pages
-
sCMOS
16 Pages
-
Luca vs Interline CCD
6 Pages
-
Low Light Imaging
8 Pages
-
Darkcurrent
3 Pages
-
iXon Back-illuminated
6 Pages
-
Revolution
23 Pages
-
High Energy Detection_2014
28 Pages
-
Clara Flyer
2 Pages
-
PRODUCT PORTFOLIO 2013
51 Pages
-
Andor Revolution XD brochure
23 Pages
-
Revolution DSD
11 Pages
-
Active Illumination Solutions
25 Pages
-
Clara Interline CCD Series
2 Pages
-
Intensified Camera Series
9 Pages
-
Neo and Zyla sCMOS
27 Pages
-
iXon
33 Pages
Archived catalogs
-
High Energy Detection_2019
8 Pages
-
Astronomy Brochure_2014
19 Pages
-
Astronomy Brochure
19 Pages
-
iKon-M USB X-Ray Brochure
2 Pages