
Catalog excerpts

OPEN-FRONT CCDs DIRECT DETECTION IMAGING Key Specifications • 1 MP or large area 4.2 MP sensors • Peak QE up to 95% (soft x-ray region) • High resolution 13x13 or 13.5x13.5 µm pixels • TE-cooling down to -100°C • Readout noise as low as 2.9 e• Labview and EPICS compatibility Key Applications P VUV/EUV/XUV Imaging P X-Ray Imaging P X-Ray Microscopy P X-Ray Diffraction (XRD) P X-Ray Plasma Imaging P X-Ray source characterization P X-Ray Phase Contrast Imaging P X-Ray Tomography P High Harmonic Generation (HHG) P Crys
Open the catalog to page 1
INTRODUCING IKON-M & -L SO High Resolution, High Sensitivity and High Dynamic Range ‘Direct’ Detection Andor’s iKon series offers outstanding sensitivity performance through a combination of > 95% QE back-illuminated sensors, low noise readout electronics and industry-leading, maintenance-free deep TE-cooling down to -100°C. It features high resolution 1 and 4.2 Megapixel large area sensor options (with 13 and 13.5 µm pixels respectively) for simultaneous high dynamic range and high spatial resolution imaging in the VUV and soft x-ray range. A convenient 16-point, knife-edge sealed 6”...
Open the catalog to page 2
FEATURES & BENEFITS Feature DN100CF / 6” CF / CF-152 flange and knife-edge sealing provided as standard for direct interfacing to vacuum chambers (rotatable design for iKon-M models). Choice of acquisition speed or large field-of-view to best match experimental needs. 13 x 13 and 13.5 x 13.5 µm pixel size options Ideal balance of dynamic range and resolution, on-head binning to extend dynamic range. High photon collection efficiency for maximising signal-to-noise ratios. ‘Enhanced’ process back-illuminated sensor options for increased QE in the soft x-ray range. Thermo-electric cooling down...
Open the catalog to page 3
TECHNICAL DATA System Specifications •2 iKon-M SO Sensor Options BN: Back-illuminated CCD, uncoated NEW BEN: Back-illuminated CCD, enhanced process, uncoated FI: Front-illuminated CCD BR-DD: Back-illuminated CCD, deep-depletion Pixel size 13.3 x 13.3 mm with 100% fill factor 27.6 x 27.6 mm with 100% fill factor Image area Minimum temperatures•4 Air cooled Coolant recirculator Coolant chiller coolant @10°C 0.75l/min Blemish specification Grade 1 sensor from supplier. Camera blemishes as defined by Andor Grade A https://andor.oxinst.com/learning/view/article/ccd-blemishes-and-non-uniformities...
Open the catalog to page 4
Quantum Efficiency Curves Quantum efficiency / % Hard X-rays Key: VUV: Vacuum Ultraviolet, EUV: Extreme Ultraviolet, XUV: Extreme Ultraviolet (X-Ray) For more information about Andor solutions for ‘indirect’ detection please go to www.andor.com/scientific-cameras/high-energy-detection *Note BN-DD has the same QE as BN below 1800 eV Dark Current Beryllium Window Transmission 100% 90% 80% BEN (iKon-L), BR-DD
Open the catalog to page 5
Frame Rates 50 kHz Precision photometry mode Binning Full Frame Full Frame Full Frame Full Frame iKon-L SO 50 kHz Precision photometry mode Full Frame Full Frame Full Frame Full Frame
Open the catalog to page 6
Typical Set-up Vacuum Chamber Photoelectrons vs Incident X-rays Flange e.g. CF203 Photoelectrons per detected X-ray iKon-M/L-SO CCD Power Supply (iKon-L only) Power Supply Power Supply Cable Best Practice Guidelines Condensation • It is strongly advised that the camera should not be used in a condensing atmosphere. • If used in a condensing atmosphere the sensor MUST be protected and the use of a cold finger is strongly recommended. Contamination & Damage • When not in use, the sensor chamber should be covered and sealed. • Due to the exposed nature of the sensor, extreme care should be...
Open the catalog to page 7
CREATING THE OPTIMUM PRODUCT FOR YOU iKon-L SO iKon-M SO example shown example shown Choose the flange hole type (iKon-L) Description No thread (ø 8 mm through hole)* Flange Hole Type * Please contact your Andor representative for further details about this option. M8 or 5/16 UNC nut required behind flange to secure bolt from vacuum chamber. Refer also to Mechanical Drawings on page 9. Choose the sensor type option Choose the cooling option (iKon-L) Back Illuminated CCD, with no AR coating 4-stage peltier cooling (Air cooled: -70ºC, Coolant recirculator: -75ºC, Coolant chiller, coolant @...
Open the catalog to page 8
MECHANICAL DRAWINGS iKon-L SO CF-152 Flange Position of pixel 1,1 3xSMB Water Connectors (x2) to suit 6.0mm ID soft PVC hose No thread, captive nuts Variation: no thread, non-captive nuts Please contact your Andor representative for further details about this option Bolts to come from this end M8 x 45 long Nut slides into cut-out Bolts to come from this end M8 x 45 long 168.1mm [6.62”] Image plane of sensor Image plane of sensor Nut rotates this side Metric attachment Image plane of sensor Bolts to come from this end Note: Please contact us for further information on attachment options...
Open the catalog to page 9
ORDER TODAY Need more information? At Andor we are committed to finding the correct solution for you. With a dedicated team of technical advisors, we are able to offer you one-to-one guidance and technical support on all Andor products. For a full listing of our regional sales offices, please see: andor.com/contact Our regional headquarters are: Europe Japan Belfast, Northern Ireland Tokyo Phone +44 (28) 9023 7126 Phone +81 (3) 6732 8968 Fax +44 (28) 9031 0792 Fax +81 (3) 6732 8939 North America China Concord, MA, USA Beijing Phone +1 (860) 290 9211 Phone +86 (10) 5884 7900 Fax +1 (860) 290...
Open the catalog to page 10All Andor Technology catalogs and technical brochures
-
Marana sCMOS
9 Pages
-
MicroPoint 4
9 Pages
-
ZL41 Cell sCMOS
7 Pages
-
Sona sCMOS
9 Pages
-
Optistat
11 Pages
-
Multi-Wavelength Imaging
11 Pages
-
BC43
13 Pages
-
andor-kymera-193-specifications
15 Pages
-
andor-dragonfly-specifications
14 Pages
-
Solis-Brochure
6 Pages
-
Spectroscopy-Solutions-Brochure
24 Pages
-
iStar CCD and sCMOS
8 Pages
-
Neo 5.5 sCMOS
6 Pages
-
Mechelle 5000
5 Pages
-
Cameras for Astronomy
8 Pages
-
Microspectroscopy Gatefold
8 Pages
-
Spectroscopy Brochure
25 Pages
-
Apogee Alta F9000
5 Pages
-
Apogee Aspen CG230
5 Pages
-
Apogee Aspen CG47
5 Pages
-
Apogee Aspen CG6
5 Pages
-
ApogeeAspen CG9000
5 Pages
-
iXon EMCCD
13 Pages
-
Zyla for Physical Sciences sCMOS
12 Pages
-
iVac OEM 2
2 Pages
-
iKon-M OEM 2-page PV
2 Pages
-
iKon-M X-Ray 2
2 Pages
-
Newton EMCCD
16 Pages
-
iQ Software
12 Pages
-
sCMOS
16 Pages
-
Luca vs Interline CCD
6 Pages
-
Low Light Imaging
8 Pages
-
Darkcurrent
3 Pages
-
iXon Back-illuminated
6 Pages
-
Revolution
23 Pages
-
High Energy Detection_2014
28 Pages
-
Clara Flyer
2 Pages
-
PRODUCT PORTFOLIO 2013
51 Pages
-
Andor Revolution XD brochure
23 Pages
-
Revolution DSD
11 Pages
-
Active Illumination Solutions
25 Pages
-
Clara Interline CCD Series
2 Pages
-
Intensified Camera Series
9 Pages
-
Neo and Zyla sCMOS
27 Pages
-
iXon
33 Pages
Archived catalogs
-
High Energy Detection_2019
8 Pages
-
Astronomy Brochure_2014
19 Pages
-
Astronomy Brochure
19 Pages
-
iKon-M USB X-Ray Brochure
2 Pages