Introduction
The iKon-M/L SO Series by Andor is a line of high-performance scientific cameras designed for applications requiring high sensitivity and resolution. These cameras feature back-illuminated sensors with peak quantum efficiency (QE) up to 95%, low readout noise, and deep thermoelectric cooling down to -100°C.
Key Specifications
- Sensor options: 1 MP or 4.2 MP with pixel sizes of 13x13 µm or 13.5x13.5 µm.
- Cooling: Thermoelectric cooling to -100°C.
- Readout noise: As low as 2.9 electrons.
- Interfaces: USB2, Labview, and EPICS compatibility.
Applications
The cameras are suitable for various imaging applications including VUV/EUV/XUV imaging, X-ray imaging, X-ray microscopy, and X-ray diffraction.
Features & Benefits
- Open-front design for direct vacuum chamber interfacing.
- High photon collection efficiency with enhanced back-illuminated sensors.
- Low noise electronics for improved signal-to-noise ratios.
- Flexible readout speeds up to 5 MHz for dynamic processes.
- Compatibility with Windows, Linux, and Labview for seamless integration.
Performance Specifications
- Peak QE: >95% for most sensor types.
- Pixel readout rates: 0.05, 1, 3, and 5 MHz.
- Dark current: As low as 0.0001 e-/pixel/sec at -100°C.
- Frame rates: Up to 4.4 fps for iKon-M and 0.953 fps for iKon-L.
System Specifications
- Sensor types include back-illuminated and front-illuminated CCDs.
- Vacuum compatibility: Greater than 10^-8 millibar.
- Mounting: DN100CF / 6” CF / CF-152 flange.
Best Practices
- Ensure vacuum environments are free of contaminants.
- Protect sensors from condensation and mishandling.
- Use appropriate cooling and sealing techniques to maintain performance.
Ordering Information
Options for flange hole types, cooling, sensor types, and accessories are available to customize the camera setup according to specific needs.
Conclusion
The iKon-M/L SO Series provides robust solutions for high-energy detection and imaging applications, offering flexibility, high sensitivity, and integration capabilities for advanced scientific research.
Warranty and Handling
The sensor has no warranty due to exposure to uncontrolled environments. Handling precautions for SO/HO open front end systems are crucial to avoid permanent damage.
Specifications
Figures are typical unless specified. Edge pixels may show partial response. Cooling temperatures are for the slowest readout speed; faster speeds may require higher cooling temperatures. Quantum efficiency is provided by the sensor manufacturer. Dark current is averaged over the CCD area, excluding blemishes. Linearity is measured up to the system's saturation point. Typical binning or array size combinations are used for measurements.
Graph and Accessories
A graph shows photoelectrons as a function of photon energy. Accessories include various cables, power supplies, a CD with user guides, a performance booklet, a protective cover plate, and fixing screws for the cover plate.
Minimum Computer Requirements
A 3.0 GHz single core or 2.4 GHz multi-core processor, 2 GB RAM, 100 MB free hard disk space (1 GB recommended for data spooling), USB 2.0 High-Speed Host Controller, and Windows (8, 8.1, 10) or Linux are required.
Operating and Storage Conditions
Operating temperature is 0°C to 30°C with relative humidity below 70% (non-condensing). Storage temperature ranges from -25°C to 50°C, with a maximum bakeout temperature of +55°C.
Power Requirements
The power requirement is 100 - 240 VAC, 50 - 60 Hz. Power consumption varies: iKon-M at 48W max, iKon-L with 4 stage cooler at 60W max, and iKon-L with 5 stage cooler at 120W max.
Weight
The iKon-M SO weighs approximately 4.9 kg, and the iKon-L SO weighs approximately 5.5 kg.
See more

Catalog excerpts

iKon-M/L SO Series-1

OPEN-FRONT CCDs DIRECT DETECTION IMAGING Key Specifications • 1 MP or large area 4.2 MP sensors • Peak QE up to 95% (soft x-ray region) • High resolution 13x13 or 13.5x13.5 µm pixels • TE-cooling down to -100°C • Readout noise as low as 2.9 e• Labview and EPICS compatibility Key Applications P VUV/EUV/XUV Imaging P X-Ray Imaging P X-Ray Microscopy P X-Ray Diffraction (XRD) P X-Ray Plasma Imaging P X-Ray source characterization P X-Ray Phase Contrast Imaging P X-Ray Tomography P High Harmonic Generation (HHG) P Crys

 Open the catalog to page 1
iKon-M/L SO Series-2

INTRODUCING IKON-M & -L SO High Resolution, High Sensitivity and High Dynamic Range ‘Direct’ Detection Andor’s iKon series offers outstanding sensitivity performance through a combination of > 95% QE back-illuminated sensors, low noise readout electronics and industry-leading, maintenance-free deep TE-cooling down to -100°C. It features high resolution 1 and 4.2 Megapixel large area sensor options (with 13 and 13.5 µm pixels respectively) for simultaneous high dynamic range and high spatial resolution imaging in the VUV and soft x-ray range. A convenient 16-point, knife-edge sealed 6” rotatable...

 Open the catalog to page 2
iKon-M/L SO Series-3

FEATURES & BENEFITS Feature DN100CF / 6” CF / CF-152 flange and knife-edge sealing provided as standard for direct interfacing to vacuum chambers (rotatable design for iKon-M models). Choice of acquisition speed or large field-of-view to best match experimental needs. 13 x 13 and 13.5 x 13.5 µm pixel size options Ideal balance of dynamic range and resolution, on-head binning to extend dynamic range. High photon collection efficiency for maximising signal-to-noise ratios. ‘Enhanced’ process back-illuminated sensor options for increased QE in the soft x-ray range. Thermo-electric cooling down to...

 Open the catalog to page 3
iKon-M/L SO Series-4

TECHNICAL DATA System Specifications •2 iKon-M SO Sensor Options BN: Back-illuminated CCD, uncoated NEW BEN: Back-illuminated CCD, enhanced process, uncoated FI: Front-illuminated CCD BR-DD: Back-illuminated CCD, deep-depletion Pixel size 13.3 x 13.3 mm with 100% fill factor 27.6 x 27.6 mm with 100% fill factor Image area Minimum temperatures•4 Air cooled Coolant recirculator Coolant chiller coolant @10°C 0.75l/min Blemish specification Grade 1 sensor from supplier. Camera blemishes as defined by Andor Grade A https://andor.oxinst.com/learning/view/article/ccd-blemishes-and-non-uniformities Advanced...

 Open the catalog to page 4
iKon-M/L SO Series-5

Quantum Efficiency Curves Quantum efficiency / % Hard X-rays Key: VUV: Vacuum Ultraviolet, EUV: Extreme Ultraviolet, XUV: Extreme Ultraviolet (X-Ray) For more information about Andor solutions for ‘indirect’ detection please go to www.andor.com/scientific-cameras/high-energy-detection *Note BN-DD has the same QE as BN below 1800 eV Dark Current Beryllium Window Transmission 100% 90% 80% BEN (iKon-L), BR-DD

 Open the catalog to page 5
iKon-M/L SO Series-6

Frame Rates 50 kHz Precision photometry mode Binning Full Frame Full Frame Full Frame Full Frame iKon-L SO 50 kHz Precision photometry mode Full Frame Full Frame Full Frame Full Frame

 Open the catalog to page 6
iKon-M/L SO Series-7

Typical Set-up Vacuum Chamber Photoelectrons vs Incident X-rays Flange e.g. CF203 Photoelectrons per detected X-ray iKon-M/L-SO CCD Power Supply (iKon-L only) Power Supply Power Supply Cable Best Practice Guidelines Condensation • It is strongly advised that the camera should not be used in a condensing atmosphere. • If used in a condensing atmosphere the sensor MUST be protected and the use of a cold finger is strongly recommended. Contamination & Damage • When not in use, the sensor chamber should be covered and sealed. • Due to the exposed nature of the sensor, extreme care should be taken...

 Open the catalog to page 7
iKon-M/L SO Series-8

CREATING THE OPTIMUM PRODUCT FOR YOU iKon-L SO iKon-M SO example shown example shown Choose the flange hole type (iKon-L) Description No thread (ø 8 mm through hole)* Flange Hole Type * Please contact your Andor representative for further details about this option. M8 or 5/16 UNC nut required behind flange to secure bolt from vacuum chamber. Refer also to Mechanical Drawings on page 9. Choose the sensor type option Choose the cooling option (iKon-L) Back Illuminated CCD, with no AR coating 4-stage peltier cooling (Air cooled: -70ºC, Coolant recirculator: -75ºC, Coolant chiller, coolant @ 10ºC,...

 Open the catalog to page 8
iKon-M/L SO Series-9

MECHANICAL DRAWINGS iKon-L SO CF-152 Flange Position of pixel 1,1 3xSMB Water Connectors (x2) to suit 6.0mm ID soft PVC hose No thread, captive nuts Variation: no thread, non-captive nuts Please contact your Andor representative for further details about this option Bolts to come from this end M8 x 45 long Nut slides into cut-out Bolts to come from this end M8 x 45 long 168.1mm [6.62”] Image plane of sensor Image plane of sensor Nut rotates this side Metric attachment Image plane of sensor Bolts to come from this end Note: Please contact us for further information on attachment options iKon-M...

 Open the catalog to page 9
iKon-M/L SO Series-10

ORDER TODAY Need more information? At Andor we are committed to finding the correct solution for you. With a dedicated team of technical advisors, we are able to offer you one-to-one guidance and technical support on all Andor products. For a full listing of our regional sales offices, please see: andor.com/contact Our regional headquarters are: Europe Japan Belfast, Northern Ireland Tokyo Phone +44 (28) 9023 7126 Phone +81 (3) 6732 8968 Fax +44 (28) 9031 0792 Fax +81 (3) 6732 8939 North America China Concord, MA, USA Beijing Phone +1 (860) 290 9211 Phone +86 (10) 5884 7900 Fax +1 (860) 290 9566...

 Open the catalog to page 10
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.