Topload bottle tester
2Pages

{{requestButtons}}

Catalog excerpts

Topload bottle tester - 1

1 CENTOR First Dynamomètre simple ANDILOG Technologies - BP 6200l - 13845 Vitrolles Cedex 9 • info@andilog.com • Tél. : +33 820 888 202 • Fax : +33 820 888 902 TOPLOAD 1000 / 2500 Bottle and packaging testing The TopLoad 1000/2500 bottle crushing systems are specially designed to provide an easy method for carrying out compression tests on bottles and small containers. The instrument can be used in the workshop or laboratory. It is fitted with a a wide plate. It can apply force of 1000 N and it can be used for bottles up to a height of 400mm. The force gauge shows force applied and the maximum compression force directly. The displacement display determines the value of the compression movement. The control console is used to start the test, to control fast upward and downward movement and to adjust the test parameters such as the speed between 10 and 350mm / min for raising and lowering the crosshead. The speed and displacement values are continuously shown on the console display. Also Available in a 2,000N capacity. The system is supplied with a Ø 50mm fixed plate. Models et capacities SPeCIFICATIONS Capacity Travel Displacement resolution Displacement accuracy Maximum vertical space Adjustable speed in mm/min Speed resolution Speed accuracy Manual high speed Mecanical stops Software stops Stop on force Cycles Worktable dimensions Overall dimensions Weight Power TOPLOAD 1000 TOPLOAD 2500 1 kN 2 kN 200 mm 300 mm 0,.01 mm 0.01 mm 0.05 mm 0.05 mm 430 mm 530 mm 10 to 350 10 to 350 1 mm/min 1 mm/min 5 % 5 % 350 mm/min 350 mm/min Yes Yes Yes Yes Yes Yes Yes Yes 200 x 300 mm 200 x 300 mm 855 x 345 x 500 947 x 345 x 500 40 kg 50 kg 220 V 220 V Topload tester for bottles Included : - Test stand STeNTOr II - One force sensor - Compression plate Ø 50 mm - Support plate Ø 100 mm - Certificate of calibration linked to COFrAC Type of tests : - Force at break : Automatic calculation of the break and peak force with automatic high speed return to the start position. - Force at a travel : Automatic calculation of the force when the bottle is compressed at a travel. Automatic high speed return to the start position. Specifications FeATureS Accuracy resolution Sampling rate Overload protection units Auto-off Bargraph Peak in tension and compression Display peak and current reading in the same time Display of the curve force / deflection Tare Force limit Average and standard deviation TOPLOAD 0,5 % Full scale 1/10000 Fule scale 1000 Hz 200% Pe N, Lb, Kg, g, Oz Adjustable 5 to 15 minuts, ã ã ã ã ã ã ã FeATureS Memory emergency stop Automatic recognition of additionnal sensors Available force sensors Manual high speed Auto return Automatic and manual tare Automatic calculations (Break, average...) Safety guard rS232 output uSB output uSB sampling rate TOPLOAD 100 results, 1 curve ã ã 20N, 50N, 100N, 200N, 500N, 1kN, 2kN ã ã ã ã Option Current value, extrema, calcuation Current value 1000 values / second

Open the catalog to page 1
Topload bottle tester - 2

2 ANDILOG Technologies BP 62001 13845 Vitrolles Cedex 9 - France info@andilog.com • www.andilog.com Tél. : +33 820 888 202 • Fax : +33 820 888 902 One touch start test rS232, uSB and TTL outputs Draw the curve directly on the test stand Mecanical travel stops Travel control panel Color touchscreen with large icons Automatic recognition of additionnal force sensors ISO 9001:2008 Certified Dimensions TOPLOAD 1000 TOPLOAD 2500 Support plate Cible Datastick : SD memory card reader to save your data directly on the card without a computer Compatible Caligraph software: Software to download...

Open the catalog to page 2

All ANDILOG Technologies catalogs and technical brochures

Archived catalogs

  1. BAT1000

    1 Pages

  2. CNR CT TM

    3 Pages

  3. CNR CT TW

    3 Pages

  4. CNR EA TT

    3 Pages

  5. CNR EA TM

    3 Pages

  6. CNR EA TH

    3 Pages

  7. CNR EA TW

    3 Pages

  8. CNR DLR

    2 Pages

  9. CNR CTR

    4 Pages

  10. CNR EAR

    3 Pages

  11. CNR DT

    2 Pages

  12. CNR FT

    1 Pages

  13. CNR EA

    2 Pages

  14. CNR CT

    4 Pages