Product catalog summary
Introduction
Anderson Power Products® has been a leader in the connector industry since 1953. The Saf-D-Grid® connector system, introduced in 2009, is designed for 380-400 VDC power distribution systems, providing safe connections for various devices up to 600 VDC. It is compatible with the IEC 320 C13 and C14 AC connection system and is UL rated for disconnecting a 400 VDC, 20 amp load.
Specifications
The Saf-D-Grid® connectors handle up to 40A and 600V DC or AC, offering greater power density compared to the IEC 320 C13 & C14 system. They are made from RoHS compliant materials, including high-temperature nylon and polycarbonate housings, stainless steel springs, and copper contacts with silver plating. The connectors are hot plug rated for 250 cycles at 400V and 20A load, with a dielectric withstanding voltage of 3,300V and an operating temperature range of -20°C to 80°C.
Safety Features
The connectors minimize the risk of personal contact with hazardous voltage, passing UL & IEC finger probe tests. They contain arcing within the housings and feature a first mate, last break ground contact for safety. An integral latch prevents accidental disconnection.
Mechanical Specifications
The connectors have a contact retention force of 20 lbf (89 N) and a plug latch retention force of 20 lbf (89 N). They are durable for up to 5,000 cycles without load and are designed to withstand mechanical shock and vibration as per IEC standards.
Temperature and Ratings
The connectors are rated under UL 1977 and IEC 61984, with specific ratings for different wire sizes and conditions of use. They are designed for both current interruption and disconnect only applications.
Tooling and Assembly
APP recommends specific tooling for compliance with UL, CSA, and other safety agencies. Using unapproved tooling voids the connector warranty. Various receptacle kits and contacts are available for different termination methods, including crimp and solder.
Drawings and Dimensions
Detailed drawings and dimensions are provided for different receptacle types, including panel cutouts and contact dimensions.
Power Cords
Various plug types are available, including wide "T" latch, small latch, and right angle "T" latch plugs, all compatible with the receptacle types. Common cable types used in Saf-D-Grid® power cords are specified for different wire sizes.
Cable Specifications
Detailed specifications for various cable types, including SJT, ST, SOOW, HVCT, H05VVF, and 60245 IEC 57, are provided. Each type is described with its voltage rating, approvals, jacket material, conductor insulation, and coloring notes.
Power Connection Design
The document outlines a simplified power connection design featuring a wide 'T' latch plug and ultra-short receptacle, ensuring touch-safe connectors.
Product Listings
Detailed tables list various power cords, specifying length, description, standards, part numbers, and packaging options.
DC Electrical Power Distribution Systems
The document discusses the advantages of DC systems over AC systems, highlighting reduced electrical losses and higher reliability. It mentions the standardization efforts by APP® in developing safety standards for low voltage DC systems.
DC Arcing and Safety
The document addresses the challenges of DC arcing, noting that the Saf-D-Grid® connector uses specific design features to mitigate damage from DC arcs.
Applications
Saf-D-Grid® connectors are suitable for use in power supplies and Power Distribution Units (PDUs) within information and communication technology racks.
Trademarks
EMerge Alliance and NEMA are registered trademarks, indicating industry recognition and compliance.
See more

Catalog excerpts

Saf-D-Grid®-1

Connector System for Higher Voltage Power Distribution Anderson Power Products®

 Open the catalog to page 1
Saf-D-Grid®-2

Safe Connections for Higher Voltage Power Distribution Systems First Mate, Last Break Ground Contact • Provides the safety of an earthing path before engagement of the power contacts. Integral Latch • Connectors cannot be accidentally unmated, preventing unwanted power loss to critical equipment. T-Latch Straight Plug Hot Plug Rated • The connectors are rated for current interruption for both electronic (capacitive) and electrical (resistive) loads. Touch Safe / Shock Protection • Minimizes the risk of personal contact with a hazardous voltage. Passes UL & IEC finger probe (plug & receptacle)...

 Open the catalog to page 2
Saf-D-Grid®-3

| TEMPERATURE CHARTS | Amperes Applied -12 AWG 14 AWG 16 AWG 18 AWG UL 1977 & IEC 61984 RATINGS | | UL 817 RATINGS | Receptacle Series Wire Size Agency Rating 3 Note: No IEC 61984 approvals for 2002N, 2002V, 2005N & 2005V series receptacles. Straight Plug / SOOW 600V 1 Note: Voltage limited by wire insulation rating 2 Note: Voltage limited by the IEC connector on the cord set | CCC RATINGS | - Pending Receptacle Series • UL1977 ratings are for recognized components under UL1977 file# E26226. Ratings may vary once the final listing category is considered. Do not exceed maximum operating temperature...

 Open the catalog to page 3
Saf-D-Grid®-4

Receptacle Housings Only Housing Style & Non-Bulk Std. Bulk Std. Panel Thickness - Part Numbers - Pack - Part Numbers - Pack Compatible Loose Piece Std. Reeled Std. Receptacles - Part Numbers - Pack - Part Numbers - Pack Flush Mount 2003G1-LPBK 1 2003G1 2,500 | TOOLING | Tooling Available Directly from Anderson Power Products (All Customers) • Contact ATS Directly to Purchase or Lease Tooling P.O. Box 6780, Harrisburg, PA 17112 USA T: 877-671-2955 F: 717-810-2862 www.applicationtooling.com NOTE: Tooling recommended by APPis required for UL, CSA & other safety agency compliance. Use of unapproved...

 Open the catalog to page 4
Saf-D-Grid®-5

| PANEL MOUNT RECEPTACLES | - For Solder Termination to Wire Receptacle Kits (Housing & Contacts) Termination Panel Non-Bulk Std. Bulk Std. Housing Type Thickness - Part Numbers - Pack - Part Numbers - Pack Flush Mount Flush Mount Flush Mount Flush Mount Flush Mount Flush Mount Flush Mount Flush Mount Short Depth Short Depth Short Depth Short Depth Short Depth Short Depth Ultra Short Depth Ultra Short Depth Ultra Short Depth Ultra Short Depth Wire, Crimp* 0.8mm Wire, Crimp* 1.0mm Wire, Crimp* 1.2mm Wire, Crimp* 1.6mm Wire, Solder 0.8mm Wire, Solder 1.0mm Wire, Solder 1.2mm Wire, Solder 1.6mm...

 Open the catalog to page 5
Saf-D-Grid®-6

See Product Drawings on the Website for Additional Information [26.80 + 0.10 L 0.00 1.055 + 0.004 - 0.000 [ 2.5 ] R. 10 MAX TYP. Panel Cut Out for All Receptacle Types [ 17.0 ] 0.67 Flush Mount & Short Contact Ultra Short Depth - For Solder Termination to Wire [ 29.0 ] 1.14 Short Depth - For Crimp Termination to Wire [ 22.6 ] 0.89 Flush Mount - For Crimp Termination to Wire [ 2.26 ] 57.4 “ Flush Mount - For Solder Termination to WireFlush Mount - For Solder Termination to PCB [ 0.55 ] | 14.0 DIM "A" (3) PLC'S Short Depth - For Solder Termination to WireShort Depth - For Solder Termination to...

 Open the catalog to page 6
Saf-D-Grid®-7

Small Latch Plug Small latch release button in the center top of the plug body. Right Angle “T” Latch Plug Right angle cord over mold to the plug with wide latch button. Simplified Power Connection Design 1. The Same Receptacle is Used on Both the Power & Load Sides. 2. The Same Plug is Used on Both Sides of the Power Cord. 3. Both Plug & Receptacle Connectors are Touch Safe. | Common Cable Types Used in Saf-D-Grid® Power Cords |Cable Voltage Jacket Conductor Conductor InsulationType Rating Approvals Material Insulation Coloring Notes SJT NOTE: Reference the plug cordset drawings for exact information...

 Open the catalog to page 7
Saf-D-Grid®-8

kCCC Pending Single-Ended Small Latch Plug Power Cord Length Non-Bulk Std. Bulk Std. M FT Description UL 817 TUV - Part Numbers - Pack - Part Numbers - Pack NOTE: Shading Indicates Build to Order

 Open the catalog to page 8
Saf-D-Grid®-9

Single-Ended Right Angle “T” Latch Plug Power Cord Length M FT Description UL 817 TUV 2.0 3.0 6.0 2.0 3.0 6.0 2.0 3.0 6.0 2.0 3.0 6.0 14 AWG ST UL 600V 90C • • 14 AWG ST UL 600V 90C • • 14 AWG ST UL 600V 90C • • 16 AWG ST UL 600V 90C • 16 AWG ST UL 600V 90C • 16 AWG ST UL 600V 90C • 18 AWG ST UL 600V 90C • 18 AWG ST UL 600V 90C • 18 AWG ST UL 600V 90C • 2.0 mm² HVCT PSE 600V 75C 2.0 mm² HVCT PSE 600V 75C 2.0 mm² HVCT PSE 600V 75C Non-Bulk - Part Numbers - Bulk - Part Numbers -

 Open the catalog to page 9
Saf-D-Grid®-10

Non-Bulk - Part Numbers - Bulk - Part Numbers - Bulk - Part Numbers - Bulk - Part Numbers - Double-Ended “T” Latch / IEC C20 Power Cord Length Non-Bulk M FT Description UL 817 TUV* - Part Numbers - 2.0 3.0 6.0 * TUV applies only to Saf-D-Grid® connector side. L Saf-D-Grid Plug Double-Ended Right Angle “T” Latch / Straight “T” Latch Plug Power Cord Length Non-Bulk M FT Description UL 817 TUV - Part Numbers - 14 AWG ST UL 600V 90C • • 14 AWG ST UL 600V 90C • • 14 AWG ST UL 600V 90C • • 16 AWG ST UL 600V 90C • 16 AWG ST UL 600V 90C • 16 AWG ST UL 600V 90C • 18 AWG ST UL 600V 90C • 18 AWG ST UL 600V...

 Open the catalog to page 10
Saf-D-Grid®-11

Double-Ended Right Angle “T” Latch / Left Angle “T” Latch Power Cord Length M FT Description UL 817 TUV NOTE: Shading Indicates Build to Order

 Open the catalog to page 11
Saf-D-Grid®-12

DC Electrical Power Distribution Systems DC Efficiency DC electrical distribution systems have a basic advantage over AC systems. By eliminating AC to DC conversions a DC distribution system is simpler than an AC system. With less electrical and electronic devices, a DC system can be designed with lower electrical losses and higher reliability. These advantages are further multiplied for systems having DC energy storage for backup power or peak shaving, or a local DC energy source such as photovoltaic cells, wind turbines or fuel cells. APP® has been a leader in the development of system and...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.