  3. TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp

TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp

TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp

TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp

Product catalog summary
Application and Usage:
Temperature sensors are designed for use in vessels and pipes, particularly for monitoring CIP/SIP processes and temperature in milk vessels. They feature a hygienic design with a Tri-Clamp sealing system and are made of FDA-compliant stainless steel, conforming to the 3-A Sanitary Standard 74-06.
Features and Advantages:
The sensors offer direct connection without an adapter, optional integrated transmitters, and various electrical connections. They are available with fast response sensor tips and pre-assembled connecting cables.
Specifications:
The sensors are made from stainless steel (AISI 304 and 316L) with a surface quality of Ra ≤ 0.8 µm. They support insertion lengths from 20 to 500 mm and operate under a maximum pressure of 10 bar. Temperature ranges include ambient (-50 to +80 °C), process (-50 to +250 °C), and CIP/SIP cleaning (up to 150 °C for 120 minutes).
Electrical Connections:
Options include cable glands and M12 plugs, with protection classes IP67 and IP69K. The sensors support 4...20 mA current loops and are compatible with various transmitter configurations.
Dimensional Drawings:
Tri-Clamp sizes range from 25 mm to 91 mm, suitable for various pipe diameters and styles as per DIN and ISO standards.
Sensor Tips and Accessories:
Sensor tips are available in diameters of 3 mm, 4 mm, and 6 mm, with response times ranging from 0.5 to 3.0 seconds for 50% response and 1.5 to 8.0 seconds for 90% response.
Warnings and Installation:
Ensure proper storage conditions, avoid mechanical shock, and comply with 3-A Sanitary Standards during installation. Electrical devices must be recycled according to national regulations.
Standards and Guidelines:
The sensors comply with the Electromagnetic Compatibility Directive 2014/30/EU and are not suitable for explosive areas or security-relevant equipment.
Order Codes:
Order codes specify sensor versions, lengths, thermowell diameters, accuracy classes, electrical connections, and transmitter options.
See more

Catalog excerpts

TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp-1

SENSORS FOR FOOD AND BIOPHARMA. Temperature Sensor Tri-Clamp Application/Specified usage ·· Temperature Measurement in vessels and pipes Application examples ·· Monitoring of CIP-/SIP-process ·· Temperature monitoring in milk vessels Hygienic design/Process connection ·· Tri-Clamp sealing system without adapter ·· Product contacting materials compliant to FDA ·· Sensor completely made of stainless steel ·· Conforming to 3-A Sanitary Standard 74-06 Features/Advantages ·· Direct Connection without adapter ·· Integrated transmitter optional ·· Different electrical connections available Options/Accessories ·· 2 x Pt100 (not retrofittable) ·· 2 x Pt100 with two transmitters (not retrofittable) ·· Pt100 chip with other classes of accuracy (1/3B, 1/10B) ·· Programmable transmitters with output 4...20 mA, 2-wire ·· Programming adapter MPU-P 9701 ·· Integrated transmitters for HART-protocol ·· Integrated transmitter MPU-LCD with display in connecting head ·· Fast response sensor tip 3 mm and 4 mm ·· Pre-assembled connecting cable in other lengths and other material Temperature Transmitter MPU-LCD with Display Application / Specified Usage ·· 4...20mA transmitter with LCD for Pt100 temperature sensor ·· For installation in temperature sensor ·· Sensor monitoring Features ·· 4-digit display with green backlight ·· Temperature measurement in °C and °F ·· Easy range select by one button ·· Lower costs for wiring because of 2-wire technology Note See product information „MPU-LCD“ for de

 Open the catalog to page 1
TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp-2

Specification Temperature sensor

 Open the catalog to page 2
TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp-3

Electrical Connection Electrical connection without transmitter Elektrischer Anschluss ohne Kopftransmitter Electrical connection with Kopftransmitter Elektrischer Anschluss mit transmitter Configuration M12 plug Belegung M12-Stecker 1: + supply 2: - supply 4...20 mA 3: not connected 4: not connected With cable gland Mit Kabelverschraubung With 2 x M12 plug Belegung 2. M12-Stecker Configuration 2nd M12 plug 4...20 mA current loop 4...20 mA Stromschleife With cable gland Belegung Klemmen terminal Configuration strip 3 4 Electrical connection with two transmitter (TFP-67) Klemmen für 1. Pt100 clamps...

 Open the catalog to page 3
TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp-4

Dimension table Tri-Clamp

 Open the catalog to page 4
TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp-5

Sensor Tips | Accessories Sensor tip diameter and response time All temperature sensors are available with smaller sensor tips, to ensure a shorter response time. The below-mentioned times were measured by emersing a temperature sensor from room temperature into boiling water. Sensor tip 0 6 mm 50 %-time: t50 < 3.0 s 90 %-time: t90 < 8.0 s Sensor tip 0 4 mm 50 %-time: t50 < 2.4 s 90 %-time: t90 < 6.5 s Sensor tip 0 3 mm 50 %-time: t50 < 0.5 s 90 %-time: t90 < 1.5 s Clamp size D [mm] (see page 4)

 Open the catalog to page 5
TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp-6

Conditions for a measuring point according to 3-A Sanitary Standard 74-06 ·· The sensors TFP-47, -57, -67, -167 conforming to the 3-A Sanitary Standard. ·· The sensors are designed for CIP-/ SIP-cleaning. Maximum 150 °C / 120 min. ·· Only with 3-A conforming Tri-Clamp connection. ·· Mounting position, self draining and the position of the leackage hole must be in accordance to current 3-A Sanitary Standard. Transport / Storage Conventional Usage ·· No outdoor storage ·· Dry and dust free ·· Not exposed to corrosive media ·· Protected against solar radiation ·· Avoiding mechanical shock and vibration...

 Open the catalog to page 6
TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp-7

Order Code Order code for version with 1 x Pt100 (connecting head 0 57 mm) (connecting head 0 57 mm, with spacer) (connecting head 0 18 mm, electrical connection via M12 plug) Sensor length EL in mm 020...500 (in steps of 5 mm) Diameter thermowell in mm 6 8 Diameter sensor tip in mm X (no reduction) 3 (only for thermowell 6 mm) 4 (only for thermowell 6 mm and 8 mm) 6 (only for thermowell 8 mm) Accuracy class Pt100 A 1/3B 1/10B Electrical connection (not selectable for TFP-167) PG (cable gland M16x1.5) M12 (M12 plug, standard with MPU-LCD) MPU-H (HART-protocol) MPU-LCD (with display) only for...

 Open the catalog to page 7
TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp-8

Order code for version with 2 x Pt100 TFP-47.2 (connecting head 0 57 mm, 2 x Pt100, no transmitter possible) TFP-57.2 (connecting head 0 57 mm, 2 x Pt100, with spacer, no transmitter possible!) TFP-67 (high connecting head 0 57 mm, 2 x Pt100, prepared for 2 x transmitter) Sensor length EL in mm 020...500 (in steps of 5 mm) Diameter thermowell in mm 6 8 Diameter sensor tip in mm X (no reduction) 3 (only for thermowell 6 mm) 4 (only for thermowell 6 mm and 8 mm) 6 (only for thermowell 8 mm) Accuracy class Pt100 A 1/3B 1/10B Electrical connection (only for TFP-47.2 and 57.2) PG (cable gland Ml6x1.5)...

 Open the catalog to page 8