TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp
8Pages

{{requestButtons}}

Catalog excerpts

TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp - 1

SENSORS FOR FOOD AND BIOPHARMA. Temperature Sensor Tri-Clamp Application/Specified usage ·· Temperature Measurement in vessels and pipes Application examples ·· Monitoring of CIP-/SIP-process ·· Temperature monitoring in milk vessels Hygienic design/Process connection ·· Tri-Clamp sealing system without adapter ·· Product contacting materials compliant to FDA ·· Sensor completely made of stainless steel ·· Conforming to 3-A Sanitary Standard 74-06 Features/Advantages ·· Direct Connection without adapter ·· Integrated transmitter optional ·· Different electrical connections available Options/Accessories ·· 2 x Pt100 (not retrofittable) ·· 2 x Pt100 with two transmitters (not retrofittable) ·· Pt100 chip with other classes of accuracy (1/3B, 1/10B) ·· Programmable transmitters with output 4...20 mA, 2-wire ·· Programming adapter MPU-P 9701 ·· Integrated transmitters for HART-protocol ·· Integrated transmitter MPU-LCD with display in connecting head ·· Fast response sensor tip 3 mm and 4 mm ·· Pre-assembled connecting cable in other lengths and other material Temperature Transmitter MPU-LCD with Display Application / Specified Usage ·· 4...20mA transmitter with LCD for Pt100 temperature sensor ·· For installation in temperature sensor ·· Sensor monitoring Features ·· 4-digit display with green backlight ·· Temperature measurement in °C and °F ·· Easy range select by one button ·· Lower costs for wiring because of 2-wire technology Note See product information „MPU-LCD“ for de

Open the catalog to page 1
TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp - 2

Specification Temperature sensor

Open the catalog to page 2
TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp - 3

Electrical Connection Electrical connection without transmitter Elektrischer Anschluss ohne Kopftransmitter Electrical connection with Kopftransmitter Elektrischer Anschluss mit transmitter Configuration M12 plug Belegung M12-Stecker 1: + supply 2: - supply 4...20 mA 3: not connected 4: not connected With cable gland Mit Kabelverschraubung With 2 x M12 plug Belegung 2. M12-Stecker Configuration 2nd M12 plug 4...20 mA current loop 4...20 mA Stromschleife With cable gland Belegung Klemmen terminal Configuration strip 3 4 Electrical connection with two transmitter (TFP-67) Klemmen für 1. Pt100...

Open the catalog to page 3
TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp - 4

Dimension table Tri-Clamp

Open the catalog to page 4
TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp - 5

Sensor Tips | Accessories Sensor tip diameter and response time All temperature sensors are available with smaller sensor tips, to ensure a shorter response time. The below-mentioned times were measured by emersing a temperature sensor from room temperature into boiling water. Sensor tip 0 6 mm 50 %-time: t50 < 3.0 s 90 %-time: t90 < 8.0 s Sensor tip 0 4 mm 50 %-time: t50 < 2.4 s 90 %-time: t90 < 6.5 s Sensor tip 0 3 mm 50 %-time: t50 < 0.5 s 90 %-time: t90 < 1.5 s Clamp size D [mm] (see page 4)

Open the catalog to page 5
TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp - 6

Conditions for a measuring point according to 3-A Sanitary Standard 74-06 ·· The sensors TFP-47, -57, -67, -167 conforming to the 3-A Sanitary Standard. ·· The sensors are designed for CIP-/ SIP-cleaning. Maximum 150 °C / 120 min. ·· Only with 3-A conforming Tri-Clamp connection. ·· Mounting position, self draining and the position of the leackage hole must be in accordance to current 3-A Sanitary Standard. Transport / Storage Conventional Usage ·· No outdoor storage ·· Dry and dust free ·· Not exposed to corrosive media ·· Protected against solar radiation ·· Avoiding mechanical shock and...

Open the catalog to page 6
TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp - 7

Order Code Order code for version with 1 x Pt100 (connecting head 0 57 mm) (connecting head 0 57 mm, with spacer) (connecting head 0 18 mm, electrical connection via M12 plug) Sensor length EL in mm 020...500 (in steps of 5 mm) Diameter thermowell in mm 6 8 Diameter sensor tip in mm X (no reduction) 3 (only for thermowell 6 mm) 4 (only for thermowell 6 mm and 8 mm) 6 (only for thermowell 8 mm) Accuracy class Pt100 A 1/3B 1/10B Electrical connection (not selectable for TFP-167) PG (cable gland M16x1.5) M12 (M12 plug, standard with MPU-LCD) MPU-H (HART-protocol) MPU-LCD (with display) only...

Open the catalog to page 7
TFP-47, -57, -67, -167 Temperature Sensor Tri-Clamp - 8

Order code for version with 2 x Pt100 TFP-47.2 (connecting head 0 57 mm, 2 x Pt100, no transmitter possible) TFP-57.2 (connecting head 0 57 mm, 2 x Pt100, with spacer, no transmitter possible!) TFP-67 (high connecting head 0 57 mm, 2 x Pt100, prepared for 2 x transmitter) Sensor length EL in mm 020...500 (in steps of 5 mm) Diameter thermowell in mm 6 8 Diameter sensor tip in mm X (no reduction) 3 (only for thermowell 6 mm) 4 (only for thermowell 6 mm and 8 mm) 6 (only for thermowell 8 mm) Accuracy class Pt100 A 1/3B 1/10B Electrical connection (only for TFP-47.2 and 57.2) PG (cable gland...

Open the catalog to page 8