Catalog excerpts
PASTE U RIZATI O N CONTROLS Sanitary Differential Level Transmitter (TDL) Electronic sensors eliminate hard-to-install capillaries position compensation issues Dual transmitter output Smaller diaphragm size simplifies spud and sensor Meets intrinsic safety requirements, HART protocol Quick Disconnect Receptacles with optional Field Wireable level transmitter with features that improve performance Driftless Level transmitters as primary inputs, installation, stability are all greatly enhanced versus competitive solutions. on 24 Volt DC power, meet intrinsic safety requirements provided a HART protocol Steel enclosure and integral most convenient using standard electronic cabling for sensor and output wiring. Dual outputs are standard, with DP (level) as the primary output, with the (pressure and/or vacuum) or bottom (total tank pressure). In most applications this can process connection. Finally, we've added additional sensor fittings for simple retrofitting to sanitary tank spuds level application where pressure and/or vacuum conditions exist. more information please visit our or contact your local Authorized Anderson Distributor. ANDERSON INSTRUMENT CO., INC • 156 AURIESVILLE RD. • FULTONVILLE, NY 12072 • USA • 800-833-0081 • FAX 518-922-8997 ANDERSON INSTRUMENT CO. LP • 400 BRITANNIA RD. EAST, UNIT 1 • MISSISSAUGA, ONTARIO L4Z1X9 • CANADA • 905-603-4358 • FAX 905-568-1652 NEGELE MESSTECHNIK GmbH • RAIFFEISENWEG 7 • D-87743 EGG A. D. GÜNZ • GERMANY • +49 (0) 8333/9204-0 • FAX +49 (0) 8333/9204-49
Open the catalog to page 1Sanitary Differential Level Transmitter Specifications DIFFERENTIAL (LEVEL) OUTPUT Medium Range: High Range: SECONDARY OUTPUT (PRESSURE AND/OR VACUUM) PERFORMANCE SPECIFICATIONS (Best Fit Straight Line) Over-Range Capacity: 60 psig - low/med range 100 - psig high range TEMPERATURE SPECIFICATIONS Process Temp. Limits: 0°- 300°F (-18°-149°C) Ambient Temp. Limits (sensor only): 15°-150°F Compensated Temp. Range (sensor only): Calibration Stability: Ambient Temp. Limits (trans Temperature Stability: Signal Output: 4-20 mA DC for level output; vacuum/total output Transmitter Enclosure Power:...
Open the catalog to page 24-20 mAwith HART Communication Analog Only (4-20mA) w/Life Sciences 4-20 mAwith HART Communication w/ Life Sciences Documentation SECONDARY OUTPUT - S.O. on total system pressure (bottom sensor) OUTPUT #2 ZERO CALIBRATION (LRV) - OUTPUT #2 FULL SCALE - DIFFERENTIAL OUTPUT UPPER RANGE LIMIT (URL)- Note: Top and bottom sensors must be specified same URL SENSOR LOCATION/TYPE - Bottom (Total Pressure) Anderson Flush Mount Long (71060-A3, A5, A7, A9) Anderson Flush Mount Short (71060-A4, A6, A8) Rosemount / Foxboro Sanitary Spud - Short Rosemount / Foxboro Sanitary Spud - Long 3" ANSI 150 Flange...
Open the catalog to page 3Sensor Fittings and Dimensions FIELD COMMUNICATIONS PROTOCOL
Open the catalog to page 4All Anderson Instrument catalogs and technical brochures
-
LA
2 Pages
-
LB/LL
4 Pages
-
SL
4 Pages
-
Turbine Flowmeter
2 Pages
-
Pressure Gauges
2 Pages
-
AWESOME 1/8 DIN Panel Meters
2 Pages
-
Thermowells
2 Pages