SL

SL

SL

Product catalog summary
Overview: The Anderson Instrument Company's "SL" Level Transmitter is designed for precise liquid level measurement in sanitary applications. It offers superior accuracy and long-term signal stability, reducing the need for frequent recalibrations and preventing costly overflow or run-dry situations.
Key Features:
  • Accuracy of 0.2% at installation, maintained over a year.
  • Field calibration with "one-touch" sensor zeroing and simple range calibration.
  • Quick disconnect receptacles and a two-year warranty covering water ingress.
  • Available in various fitting and range combinations, all CE compliant and meeting 3-A Sanitary Standards.
Performance Specifications:
  • Level Measurement Ranges: SL1 & SL5 (0-30" to 0-140" w.c.), SL2 & SL6 (0-140.1" to 0-415" w.c.), SL3 & SL7 (0-415.1" to 0-830" w.c.), SL4 & SL8 (0-830.1" to 0-1385" w.c.).
  • Calibrated Accuracy: ±0.20% of URL.
  • Temperature Limits: Process (0°F to 265°F), Ambient (15°F to 120°F).
  • Response Time: 526 mSec.
  • Output: 4-20mA dc, 2-wire with optional Hart digital protocol.
Materials and Construction:
  • Housing Material: 304 and 316 stainless steel.
  • Wetted Parts: 316L stainless steel electropolished.
  • Ratings: NEMA 4X, IP-66, IP-67.
Applications:
  • Inventory Control
  • Batching/Mixing Control
  • Suitable for both conductive and non-conductive fluids.
Ordering Information: The document provides detailed part numbers for various fittings, connectors, and accessories, ensuring compatibility with different tank configurations and installation requirements.
See more

Catalog excerpts

SL-1

PASTEURIZATION CONTROLS New technology proven to eliminate long-term signal drift — provides substantial savings in all inventory applications! • Fewer tune-ups * More reliable inventories * 3-A compliant; Third party Special Features Include: * Quick Disconnect Receptacles with optional Field Wiring Connectors * One-Touch Field Calibration * Available with Hart • Inventory Control • Batching/Mixing Control Anderson Instrument liquid level in sanitary Transmitter incorporates state superior accuracy and long term signal stability. The field tested performance of repetitive re-calibrations along with protection against costly overflow/run-dry situations that can occur with less stable level transmitters. The expected a year later! We've also incorporated a field calibration feature that provides "one-touch" sensor zeroing as well as simple range calibration, without the need for special tools and fixtures, pressure sources, or removal ofthetransmitterfrom the tank. This translates to real cost savings during installation application requirements. With quick disconnect receptacles; we have even extended our two-year warranty to cover water ingression. fitting and range combinations you'll need to fit any sanitary tank application. All variations ANDERSON INSTRUMENT CO., INC • 156AURIESVILLE RD. • FULTONVILLE, NY 12072 • USA • 800-833-0081 • FAX 518-922-8997 ANDERSON INSTRUMENT CO. LP • 400 BRITANNIA RD. EAST, UNIT 1 • MISSISSAUGA, ONTARIO L4Z 1X9 • CANADA • 905-603-4358 • FAX 905-568-1652 NEGELE MESSTECHNIK GmbH • RAIFFEISENWEG 7 • D-87743 EGG A. D. GÜNZ • GERMANY • +49 (0) 8333/9204-0- FAX+49 (0) 8333/9204-49

 Open the catalog to page 1
SL-2

Level Measurement Ranges: (Factory calibrated at no charge and easily field calibrated within the parameters listed below) Minimum Maximum fURL*i Proof Pressure Ranges to accomodate vacuum available on request Calibrated Accuracy: (includes repeatability, hysteresis, and linearity) ±0.2% of Upper Range Limit 2 times the URL (see table above) Calibration Stability: Process Temperature Limits: Ambient Temperature Limits: Compensated Temp. Range: Temperature Stability: Over-Range Capacity: Response Time: Analog + Hart digital protocol. Does not support Multidrop mode URL = Upper Range Limit Power...

 Open the catalog to page 2
SL-3

SPAN RANGE Anderson Flush Mount Long Anderson Flush Mount Short Cherry Burrell Flush Mount Long (insulated tank) Cherry Burrell Flush Mount Short (uninsulated tank) King Gage Flush Mount Long3 King Gage Flush Mount Medium King Gage Flush Mount Short Tank Mate Flush Mount Long1.3 Tank Mate Flush Mount Medium1 Tank Mate Flush Mount Short1 Continental (long) Rosemount / Foxboro Sanitary Spud - Short3 Rosemount / Foxboro Sanitary Spud - Long3 Endress & Hauser Universal Adaptor - Short Endress & Hauser Universal Adaptor - Long Liquid Scale Flush Mount Medium2.3 Field Calibrated '—SENSOR WIRING 01...

 Open the catalog to page 3
SL-4

Sensor Fittings and Dimensions 3-7/64" 3-7/64" "A" "A" 3-7/64" 3-7/64" "A" "A" 3-7/64" 3-7/64" 3-7/64" 3-7/64" 3"3" "A" "A" 2"2" DIA. DIA. 3" 3" 3-19/64" 3-19/64" "A" "A" 2" 2" DIA. DIA. 2-1/4" 2-1/4" 3-19/64" 3-19/64" 3-19/64" 3-19/64" 1-1/4" DIA. 1-1/4" DIA. 2-1/4" 2-1/4" 3-19/64" 3-19/64" 1-1/4" DIA. 1-1/4" DIA. KING SHELL TYPE KING SHELL TYPE "A" "A" NON INSULATED 2-3/16 NON INSULATED 2-3/16 STANDARD 6-9/16 KING SHELL TYPE "A" 8-13/16 NON LONG INSULATED 2-3/16 2-3/16 8-13/16 NON LONG NON INSULATEDINSULATED2-3/16 STANDARD 6-9/16 STANDARD 6-9/16 STANDARD LONG LONG 6-9/16 8-13/16 8-13/16 "A"...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.