Catalog excerpts
Maximum Flexibility in UV/Vis
Open the catalog to page 1ScanDrop2 The ScanDrop2 from Analytik Jena is the 2nd generation of microvolume spectrophotometers uniting flexibility and reliability with innovative technology and modern design all in a single instrument. A flexible, easy-to-use platform for measuring small volumes of 0.3 µl or more, the new ScanDrop2 and its familiar walkaway principle allow operators to process samples either individually or in a series of up to 16 samples. The ability to record the entire spectrum from 190 nm to 1000 nm in only one second makes the system the ideal choice for UV/Vis applications, particularly for...
Open the catalog to page 2Efficient, robust UV/Vis spectrophotometer ■■ recise: UV/Vis adsorption measureP ments between 190 nm and 1000 nm ■■ Optimum: CCD detector for optimized resolution ≥ 1.2 nm ■■ Powerful: Only 1 sec per spectrum/ sample for fast results ■■ Long-lasting: Highly precise, fiberless optical system combined with a powerful xenon flash lamp Innovative design for reliable handling ■■ Simple: Easy handling just pipette the sample and take your measurement ■■ Intelligent: Rotating mechanism opens instrument for optimum access and view of the 10” tablet PC ■■ Brilliant: 2D scanning area adaptable to...
Open the catalog to page 3Efficient, Robust Spectrophotometer This flexible, precise spectrophotometer raises the bar for UV/Vis measurements at wavelengths ranging from 190 nm to 1000 nm, making it ideal for protein and nucleic acid applications. The ScanDrop2 is a versatile, robust instrument that is user friendly without sacrificing measurement reliability. Optimized for the UV/Vis range, its symmetrical Czerny-Turner design with a linear CCD detector ensures excellent stability and reproducible results while offering a high level of resolution (≥ 1.2 nm). Its long-lasting xenon flash lamp, which, unlike other...
Open the catalog to page 4Innovative Design for Reliable Handling Clever design: Measurements with the ScanDrop² are very easy and reliable, thanks to how the instrument opens and automatically positions samples in the path of the beam. The instrument opens automatically in the front with a 180° rotating motion that provides optimum access for sample positioning. This also guarantees an unobstructed view of the adapted 10” tablet PC used for operating the instrument every time. The direction of the opening mechanism can be switched to accommodate right- and left-handed operators. This eliminates the need for opening...
Open the catalog to page 5Flexible Adaption to Meet a Variety of Demands Designed around a successful walk-away principle, the ScanDrop2 is a powerful, versatile UV/Vis spectrophotometer for testing either individual samples or simple series of samples. In addition to working as a standard photometer with a 10 mm cuvette position, the ScanDrop² also accommodates various adapters that allow it to run multiple samples in parallel. CHIPCUVETTE® The ScanDrop2 utilizes the unique, patented CHIPCUVETTE®, which allows the user to test samples ranging in volume from 0.3 µl to 4 µl. At the same time, CHIPCUVETTE® includes 16...
Open the catalog to page 7Reliable Data Capture and Simple Evaluation The FlashSoftPro control and analysis software, which is available in a standard PC version and in a version optimized for tablets with touchscreens, incorporates features and analysis modules exceeding all expectations. The integrated 10” tablet PC turns the ScanDrop2 into a compact, stand-alone system based on Windows 8.1 that can be operated with no peripherals. The ScanDrop2 can also be operated from a standard PC or laptop. In addition to its easy-to-use, uncluttered menu interface, the software also comes with a series of preinstalled...
Open the catalog to page 8Control and analysis software FlashSoftPro
Open the catalog to page 9Technical Data Spectral photometer data Wavelength precision Absorptions rang Spectral resolution Wavelenght reproducibility Absorption accuracy Photometric reproducibility Measuring principle Polychromator system with symmetric Czerny-Turner Light source Xenon Flash Lamp Wavelenght range Linear CCD detector optimized to UV/Vis Sample amount Sample parameter Number of samples 1 to 16 sample @ 2 path length parallel Sample handling M easurement of samples by using cuvettes (10 mm or CHIPCUVETTE®) O ptional: measurements without consumables by Butterfly Cuvette Application UV/Vis Cuvette Path...
Open the catalog to page 10Technical Data Dimensions Weight Additional technical data Interface PC connection: USB Tablet: USB for data transfer, barcode reader
Open the catalog to page 11Order Information Order Number ScanDrop² Device combination for usage of different adapter and 10 mm cuvette measurement position, without PC, incl. software FlashSoftPro Butterfly Cuvette for ScanDrop² Flip-top cuvette incl. adapter for UV/Vis measurements without consumables, 9 positions with 1 mm path lenght each CHIPCUVETTE® Adapter for ScanDrop² Adapter for CHIPCUVETTE® and UV/Vis measurements using ScanDrop², double determination of 1 to 16 sample at 0.1 mm and 1.0 mm path lenght Standard Cuvette Adapter for ScanDrop² Adapter for up to 8 Standard Cuvettes (10 mm) and UV/Vis...
Open the catalog to page 12All Analytik Jena GmbH+Co. KG catalogs and technical brochures
-