Total Chlorine Monitor Model Q46H/79S
4Pages

{{requestButtons}}

Catalog excerpts

Total Chlorine Monitor Model Q46H/79S - 1

Chlorination of potable water, wastewater effluent, and industrial cooling water is widely used throughout the world to control biological activity in the water. Disinfection of potable water with chlorine ensures that tap water is safe to drink after passing through the distribution system piping. Wastewater disinfection helps to ensure that receiving streams are safe for recreational use, and cooling water chlorination reduces biofouling that can degrade heat transfer efficiency. This wide use of chlorination for disinfection purposes results in the need for a reliable “residual chlorine” analyzer that can operate in a variety of applications. Non-Contacting “Total Chlorine” Monitoring Call 800.959.0299 to speak with a sales representative or visit us on the web at www.analyticaltechnolog

Open the catalog to page 1
Total Chlorine Monitor Model Q46H/79S - 2

Residual chlorine is found in many chemical forms in water systems. Residuals in clean water are often predominantly free chlorine while wastewater and cooling water can contain mixtures of free chlorine, combined chlorine, and organochlorine species. Measurement of residual chlorine in applications where only free chlorine (potable water) or only combined chlorine (chloraminated water) exist can often be monitored with direct sensor measurement. However, applications where a variety of chlorine forms can exist (wastewater effluent and some cooling water) require a more complicated...

Open the catalog to page 2
Total Chlorine Monitor Model Q46H/79S - 3

FEATURES Gas Phase Sensing. Measurement is made without contact between sample and sensor, eliminating the potential for sensor fouling. Standard Method. Total Chlorine is measured using EPA recommended iodometric measurement after reaction of the sample with buffer and potassium iodide. Analog Output Options. Two isolated 4-20 mA outputs are standard. One output is programmable for PID function. Three Control Relays. Relays are programmable for setpoint, deadband, and time delay. Digital Communications. Communication options for Profibus-DP, Modbus-RTU, or Ethernet-IP. Clear Display....

Open the catalog to page 3
Total Chlorine Monitor Model Q46H/79S - 4

Display Range ORDERING INFORMATION Model Q46H/79S-A-B Total Chlorine Monitor Suffix A - Power 1 - 115 VAC, 50/60 Hz 2 - 230 VAC, 50/60 Hz Suffix B - Digital Output 1 - None 2 - Profibus-DP 3 - Modbus-RTU 4 - Ethernet-IP ACCESSORIES 31-0038 7-c Sensor interconnect cable, 100 ft max. 05-0094 Panel Mount Bracket Kit 47-0005 2"U-bolt, 304SS CHEMISTRY MODULE Sensor All systems are supplied with one package of membranes, one 120 cc bottle of electrolyte, one 50 gram container of Kl, 2 reagent bottles with reagent pickup assemblies, and 2 reagent bottle brackets. ATI's Solution to Dechlorination...

Open the catalog to page 4