Catalog excerpts
Replace unreliable sensors & cut maintenance costs. The Q22 Specialty pH/ORP sensors are designed for use with all non-ATI analyzer systems and generic panel meters, allowing these end users to utilize the same robust features of the standard ATI Q25 sensors. The sensors are classified as either Universal or Loop-Powered, depending on the output selected. The Universal sensors emulate standard, non-amplified combination sensors and are designed to interface with all non-ATI pH/ORP analyzers. The sensors require no power supply as the preamplifier is powered by an internal lithium battery. The pH sensor outputs a mV signal in the range of either -500 to +500 mV or 0 to 2 VDC; both are linear over the 0 to 14 pH range. The ORP sensor outputs a mV signal that ranges from -1000 to +1000 mV. These sensors may be used as replacement sensors for use with all non-Quantum analyzers. The Loop-powered sensors require an external 7-30 VDC power supply and provide a 4-20 mA output signal for direct connection to generic panel meters, data acquisition systems, or other devices that accept a current input. The sensor includes integral temperature compensation of the pH signal, so no temperature output is provided. The sensor output is uncalibrated, therefore, the receiving instrument must be capable of providing user calibration of the pH or ORP signal on a periodic basis. System Features Differential-Style Sensor: The reference element is a second glass pH electrode immersed in a reference buffer solution. This glass reference system allows the sensor to be used in applications that poison conventional pH or ORP sensors. Integral Preamplifier: The integral preamplifier is encapsulated in the body of the sensor. This creates a low impedance signal output which ensures stable readings in harsh environments, and maximizes the distance between sensor and analyzer. PEEK® or 316SS Sensor Body Construction: All sensor housings are constructed of either PEEK®, a high performance thermoplastic that provides outstanding mechanical strength and chemical resistance, or 316 stainless steel. Multiple Electrode Types: Sensor electrodes are userspecified to ensure measurement reliability and maximum sensor lifetime. The type of pH electrode can be selected for optimal performance. The metal ORP electrode is either platinum or gold, depending on the process chemicals. Replaceable Sensor Saltbridge: A large volume, dual junction saltbridge is used to maximize the in-service time of the sensor. The replaceable saltbridge allows for easy and inexpensive sensor regeneration.
Open the catalog to page 1Ordering Information: Model Q22-A-B-C-D-E Sensor Model Q22 Sensor Specifications Measuring Range: Sensitivity: Stability: Wetted Materials Temperature Compensation: Sensor Cable: Temperature Range: Pressure Range: Max. Flow Rate: Max. Sensor to Analyzer Distance: Sensor Body Options: Shipping Weight: 0 to 14 pH; 0 to +1000 mV or ±1000 mV 0.002 pH; 0.2 mV 0.02 pH; 2 mV (per 24 hours, non-cumulative) PEEK®, ceramic, titanium, glass, Viton®, EDPM Platium or Gold : ORP 316 Stainless Steel with sanitary or insertion body styles Pt100 or Pt1000 RTD 6 conductor plus 2 shields, HDPE Jacket -5 to...
Open the catalog to page 2All Analytical Technology catalogs and technical brochures
-
C12-17
2 Pages
-
F12/D
4 Pages
-
D16 PortaSens III
4 Pages
-
ChlorLog
2 Pages
-
Model Q46H/83
4 Pages
-
E12-15 IR
2 Pages
-
Ammonia Monitor Model Q46N
4 Pages
-
Metrinet
4 Pages
-
B12 Wet Gas Detector
2 Pages
-
B14 Gas Alarm Module
4 Pages
-
Q45S Wet H2S Gas Detector
4 Pages
-
A14/A11 Modular Gas Detector
8 Pages
-
Model Q45N
4 Pages
-
Q45H/64
2 Pages
-
Q45C2
2 Pages
-
Model Q45P/R
2 Pages