Model Q46H/83

Model Q46H/83

Model Q46H/83

Product catalog summary
Overview: The Permanganate Monitor Model Q46H/83 is designed for continuous monitoring of permanganate (MnO4-) concentrations in water, primarily used for reducing organics and controlling zebra mussels in raw water intake structures. It helps operators adjust chemical feed rates to achieve target values and quickly identify feed problems.
Key Features:
  • Gas-Phase Measurement: Utilizes a gas-phase approach to avoid sensor contamination by manganese dioxide (MnO2) deposits.
  • Components: Consists of an electronic display unit and a chemistry module with sample and reagent pumps, and a gas sensor.
  • Display and Outputs: Features a large back-lit LCD display, three SPDT alarm relays, and two 4-20 mA outputs. Digital communication options include Profibus-DP, Modbus-RTU, and Ethernet-IP.
Theory of Operation: The monitor uses an Auto-Chem chemistry module to treat the sample, strip iodine gas, and measure it. The sample is mixed with pH buffer and potassium iodide, and the resulting iodine is measured using an amperometric membraned sensor.
Installation: The system requires AC power and includes a 25 ft sensor cable, extendable up to 100 ft. It supports a sample flow rate of 5-20 gallons per hour.
Specifications:
  • Sensor Type: Membraned Iodine Gas Sensor
  • Response Time: 95% in 3 minutes
  • Power: 115 or 230 VAC, 50/60 Hz
  • Operating Temperature: 2 to 50°C
Ordering Information: Model Q46H/83-A-B with options for power and digital output configurations.
Additional Products: The document also mentions the Q46S/66 Residual Sulfite Monitor for dechlorination control in wastewater effluent.
See more

Catalog excerpts

Model Q46H/83-1

Permanganate (MnO4-) is a strong oxidizer used in the water industry for reduction of organics in raw water. It is also used for control of zebra mussel problems at raw water intake structures. Continuous monitoring of low permanganate concentrations allows operators to adjust chemical feed rates and achieve target values. Chemical feed problems that result in either too little or too much residual can be quickly identified and corrected. Monitor MnO4- without Sensor Contamination! Call 800.959.0299 to speak with a sales representative or visit us on the web at www.analyticaltechnology.com

 Open the catalog to page 1
Model Q46H/83-2

Continuous monitoring of permanganate in treated water presents sensor contamination issues. When permanganate reacts with organics or other reducing materials in solution, manganese dioxide (MnO2) is formed and readily plates out on sensing electrode surfaces. The resulting deposits degrade the measurement and can be difficult to clean. The Q46/83 eliminates this problem by employing a measurement method in which the sensor never comes into contact with the sample. In operation, water containing permanganate is mixed with pH buffer and potassium iodide solutions. Permanganate oxidizes the iodide...

 Open the catalog to page 2
Model Q46H/83-3

FEATURES Gas Phase Sensing. Measurement is made without contact between sample and sensor, eliminating the potential for sensor fouling. Standard Method. Permanganate is measured using iodometric measurement after reaction of the sample with buffer and potassium iodide. Analog Output Options. Two isolated 4-20 mA outputs are standard. One output is programmable for PID function. Three Control Relays. Relays are programmable for setpoint, deadband, and time delay. Digital Communications. Communication options for Profibus-DP, Modbus-RTU, or Ethernet-IP. Clear Display. Back-lit large LCD display...

 Open the catalog to page 3
Model Q46H/83-4

ELECTRONIC MONITOR Display Range CHEMISTRY MODULE ORDERING INFORMATION Model Q46H/83-A-B Permanganate Monitor Suffix A - Power 1 - 115 VAC, 50/60 Hz 2 - 230 VAC, 50/60 Hz Suffix B - Digital Output 1 - None 2 - Profibus-DP 3 - Modbus-RTU 4 - Ethernet-IP ACCESSORIES 31-0038 7-c Sensor interconnect cable, 100 ft max. 05-0094 Panel Mount Bracket Kit 47-0005 2"U-bolt, 304SS NOTE: All systems are supplied with one package of membranes, one 120 cc bottle of electrolyte, one 50 gram container of Kl, 2 reagent bottles with reagent pickup assemblies, and 2 reagent bottle brackets. Sensor Type ATI's Solution...

 Open the catalog to page 4

All Analytical Technology catalogs and technical brochures

  1. C12-17

    2  Pages

  2. F12/D

    4  Pages

  3. ChlorLog

    2  Pages

  4. E12-15 IR

    2  Pages

  5. Metrinet

    4  Pages

  6. Model Q45N

    4  Pages

  7. Q45H/64

    2  Pages

  8. Q45C2

    2  Pages

  9. Q22PX

    2  Pages

  10. Model Q45P/R

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.