D12-IR Combustible Gas Transmitter

D12-IR Combustible Gas Transmitter

D12-IR Combustible Gas Transmitter

Product catalog summary
Overview: The D12-IR Gas Transmitter by ATI is a versatile infrared system designed for detecting LEL or select toxic gases. It features a compact IR sensor housed in a corrosion-resistant enclosure, suitable for hazardous environments. The transmitter offers improved stability and sensor longevity by eliminating issues common with catalytic bead sensors.
Configurations: The D12-IR is available in four configurations:
  • Transmitter: Operates in 3-wire mode with an integral LCD for gas concentration and alarm indication.
  • Transmitter with HART™: Supports HART™ protocol for communication, offering 4-20 mA and constant current modes.
  • Transmitter with Integral Relays: Provides three relay outputs for local alarm functions, programmable for setpoints and delays.
  • Transmitter with Modbus™: Includes RS-485 communication with Modbus™ interface, supporting up to 247 unique addresses.
Key Features:
  • LCD Graphics Display: Displays gas concentrations and alarm indications with a backlight for visibility.
  • Internal Data Logger: Stores measured gas values at user-defined intervals, retrievable via MODBUS™.
  • Non-Intrusive Operation: Allows adjustments without opening the enclosure using a magnetic tool.
  • Password Protection: Secures program settings with a user-selectable 4-digit password.
  • Modular Electronics: Easy plug-in assembly for quick replacement.
  • Explosion Proof Enclosure: Rated for hazardous areas, certified by UL, FM, and CSA.
  • Scalable 4-20 mA Output: Programmable output range within sensor boundaries.
  • Fail-safe Sensor Operation: Continuously monitors sensor functions, indicating problems on display and analog output.
  • High Range Methane Measurement: Factory calibrated for volumetric methane measurements, with ranges from 0-10% to 0-100% by volume.
  • Sensor Calibration History: Stores calibration data for review.
  • Three Internal Alarm Relays: Programmable for various alarm functions, with remote reset capability.
  • Analog and Relay Output Simulation: Allows testing without applying gas to the sensor.
  • Serial Communication Interface: Available with HART™ or MODBUS™ protocols for comprehensive communication and control.
Specifications:
  • Gas Types: Combustible gases, CO2, methane, N2O.
  • Sensor Type: Single path Non-dispersive Infrared (NDIR).
  • Range: Various ranges for different gases, including 0-100% V/V for methane.
  • Response Time: 90% in 10 seconds.
  • Accuracy: Generally ±5% of value.
  • Power: 12-30 VDC, 350 mA maximum.
  • Enclosure: Explosion-proof, Class 1, Div. 1, Groups B, C, & D.
  • Operating Temperature: -40º to +75ºC.
Ordering Information: Model D12IR-E-F-G with various suffixes for transmitter type, gas & range, and digital output options.
See more

Catalog excerpts

D12-IR Combustible Gas Transmitter-2

ATI’s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact IR sensor in a corrosion resistant housing with sintered flame arrestor to meet hazardous area classification requirements, and is suitable for most plant environments. The D12-IR gas transmitter eliminates the poisoning problems inherent in catalytic bead sensors. While catalytic LEL sensors offer reliable service, the presence of silicon vapors, hydrogen sulfide, and halogenated hydrocarbons can quickly degrade sensor performance....

 Open the catalog to page 2
D12-IR Combustible Gas Transmitter-3

Features For Every Application • LCD Graphics Display: Gas concentrations are displayed in • Fail-safe Sensor Operation: Because the IR sensor is large, easy to read numbers. The display also provides alarm always in an active state, the transmitter continuously moni- indication and complete menus for setting up operating para- tors critical sensor functions and indicates any sensor prob- meters. A backlight is standard for good visibility in low light. lems, both on the display and via the analog output. • Internal Data Logger: Measured gas values are stored at • High Range Methane Measurement:...

 Open the catalog to page 3
D12-IR Combustible Gas Transmitter-4

Combustible gas, carbon dioxide, volumetric methane, or nitrous oxide Combustible gas selectable for methane, ethane, propane, or butane Sensor Type: Single path Non-dispersive Infrared (NDIR) Sensor Separation: Maximum 25’ cable from sensor to transmitter Range: Combustible Gas: 0-50% LEL min., 0-100% max., or 0-100% V/V methane High Hydrocarbon: 0-10% min., 0100% max. V/V for heavier hydrocarbons Carbon Dioxide: 0-2000 PPM min., 0-50% max. Nitrous Oxide: 0-2000 PPM min., 0-1% max Response Time: 90% in 10 seconds Accuracy: Generally ±5% of value, but limited by available calibration gas accuracy...

 Open the catalog to page 4

All Analytical Technology catalogs and technical brochures

  1. C12-17

    2  Pages

  2. F12/D

    4  Pages

  3. ChlorLog

    2  Pages

  4. Model Q46H/83

    4  Pages

  5. E12-15 IR

    2  Pages

  6. Metrinet

    4  Pages

  7. Model Q45N

    4  Pages

  8. Q45H/64

    2  Pages

  9. Q45C2

    2  Pages

  10. Q22PX

    2  Pages

  11. Model Q45P/R

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.