Overview: The Series B12 is a 2-wire gas transmitter designed to transmit a 4–20 mA signal proportional to gas concentration. It operates on a 24 VDC power supply and can drive loads up to 675 ohms. It can also function at 12 VDC for battery-operated applications with reduced load capacity.
Specifications:
  • Gas Type: Customer-selected from a list of available sensors.
  • Range: Standard range provided unless specified otherwise.
  • Accuracy: Generally ±5% of value, limited by calibration gas accuracy.
  • Repeatability: ±1% of full scale.
  • Linearity: ±0.5% of full scale.
  • Zero Drift: Sensor dependent, generally less than 2% per month.
  • Span Drift: Application dependent, generally less than 3% per month.
  • Output: Loop-powered 4–20 mA, 675 ohms max at 24 VDC.
  • Power: 12–30 VDC.
  • Enclosure: NEMA 4X Polystyrene, optional explosion-proof.
  • Controls: Zero and span potentiometers on the circuit board.
  • Operating Temperature: -30° to +55°C (oxygen: -10° to +55°C).
  • Pressure Limits: 7–30 PSIA (0.5–2 Bar).
  • Weight: 0.25 lbs; 1.75 lbs for explosion-proof unit.
  • Display: Optional 3-Digit LCD (not available with explosion-proof enclosure).
Gas and Range Availability: The document provides a comprehensive list of gases and their minimum and maximum detection ranges, including ammonia, carbon monoxide, hydrogen, nitric oxide, oxygen, and others.
Ordering Information: Model numbers are specified using suffixes for gas type, enclosure type, measurement range, and units of measurement. Accessories such as calibration adapters and flowcell assemblies are also available.
Contact Information: Analytical Technology, Inc. provides contact details for their US and UK offices for further inquiries and orders.
See more

Catalog excerpts

B12 2-Wire Modular Gas Detector-2

Series B12 transmitters are loop-powered instruments Transmitters are normally supplied with the sensor that transmit a 4–20 mA signal linearly proportional to close coupled to the enclosure. However, for special gas concentration. Operated from a 24 VDC power applications, the unit can be supplied with separate supply, the transmitter will drive loads up to 675 ohms sensors that can be located up to 25 feet from the — sufficient for most monitoring applications. transmitter. Sensor duct mounting adapters and Alternatively, the unit can operate at 12 VDC — with sensor flowcells can also be provided...

 Open the catalog to page 2
B12 2-Wire Modular Gas Detector-3

Specifications Gas Type: Range: Accuracy: Electronic Repeatability: Electronic Linearity: Zero Drift: Span Drift: Output: Power: Enclosure: Controls: Operating Temperature: Sensor Pressure Limits: Weight: Display: Customer-selected from available sensor list Supplied with standard range for each gas unless otherwise specified Generally ±5% of value, but limited by available calibration gas accuracy ±1% of full scale ±0.5% of full scale Sensor dependent, but generally less than 2% of full scale per month, non-cumulative Application Dependent, but generally less than 3% per month. Loop-powered...

 Open the catalog to page 3
B12 2-Wire Modular Gas Detector-4

How To Order Specify model number using the suffixes below. Model B12-CC-D-EEEE 2-Wire Gas Transmitter Suffix CC Gas Type – Standard range shown in parentheses 10 - Bromine (0-2 PPM) 11 - Chlorine (0-10 PPM) 12 - Chlorine Dioxide (0-2 PPM) 13 - Fluorine (0-2 PPM) 14 - Ozone (0-2 PPM) 15 - Ammonia (0-100 PPM) 16 - Carbon Monoxide (0-100 PPM) 18 - Hydrogen (0-4%) 19 - Oxygen (0-25%) 20 - Phosgene (0-2 PPM) 21 - Hydrogen Chloride (0-20 PPM) 22 - Hydrogen Cyanide (0-20 PPM) 23 - Hydrogen Fluoride (0-20 PPM) 24 - Hydrogen Sulfide (0-50 PPM) 25 - Nitric Oxide (0-100 PPM) 25 - Nitrogen Dioxide (0-20...

 Open the catalog to page 4

All Analytical Technology catalogs and technical brochures

  1. C12-17

    2  Pages

  2. F12/D

    4  Pages

  3. ChlorLog

    2  Pages

  4. Model Q46H/83

    4  Pages

  5. E12-15 IR

    2  Pages

  6. Metrinet

    4  Pages

  7. Model Q45N

    4  Pages

  8. Q45H/64

    2  Pages

  9. Q45C2

    2  Pages

  10. Q22PX

    2  Pages

  11. Model Q45P/R

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.