Analytical Technology PQ45 Portable Monitor & Data-Logger System
4Pages

{{requestButtons}}

Catalog excerpts

Analytical Technology PQ45 Portable Monitor & Data-Logger System - 1

Mooddeell PPQQ4455 Portable Water Quality Monitoring System Portable System for Water Quality Monitoring

Open the catalog to page 1
Analytical Technology PQ45 Portable Monitor & Data-Logger System - 2

Portable monitoring systems operate continuously for up to 30 days on 2 internal C-cell batteries. Rechargeable C-cell batteries may be substituted for the standard alkaline batteries, but the duration of operation will be different depending on the batteries used. As an option, the internal batteries may be eliminated and a terminal block is supplied for connection to an external 5-17 VDC power supply. This option allows easy adaptability to solar power systems. Complete P-Q45 systems are supplied in a durable carrying case with provision for user supplied locks to protect from tampering....

Open the catalog to page 2
Analytical Technology PQ45 Portable Monitor & Data-Logger System - 3

Water connections are made using flexible inlet and drain tubing. Fittings are supplied for the user to adapt tubing to piping systems. Other than a shut-off valve at the sample point, no additional flow controls are required. The P-Q45 contains a flow regulation device that will maintain sample flow at about 400 cc/min. at any inlet pressure from 5-100 PSI (0.3-7 Bar). An internal V-strainer protects the flow control from any large particles, and the fittings supplied for liquid connection contain internal valves that stop flow as soon as the fitting is disconnected. A 20ft length of...

Open the catalog to page 3
Analytical Technology PQ45 Portable Monitor & Data-Logger System - 4

Measurement Type: Dissolved Oxygen 0-40.00 PPM Combined Chlorine 0-2.000 PPM Min., 0-200 PPM Max. Free Chlorine 0-2.000 PPM Min., 0-200 PPM Max. Dissolved Ozone 0-200 PPB Min., 0-20.00 PPM Max. Dissolved ClO2 0-200 PPB Min., 0-20.00 PPM Max. Conductivity 0.0 – 200 ìS Min., 0.00 – 2 S Max. pH 0.00 – 14.00 pH ORP -1000 to +2000 mV Sensor Type: Voltametric, potentiometric or conductance Response Time: 90% in 60 seconds average (dependent on type of measurement) Accuracy: ± 1% of range typical Repeatability: ± 0.5% of range typical Electronic Linearity: ± 0.5% of Full Scale Zero Drift: < 1%...

Open the catalog to page 4

All Analytical Technology catalogs and technical brochures

  1. C12-17

    2 Pages

  2. F12/D

    4 Pages

  3. ChlorLog

    2 Pages

  4. E12-15 IR

    2 Pages

  5. Metrinet

    4 Pages

  6. Model Q45N

    4 Pages

  7. Q45H/64

    2 Pages

  8. Q45C2

    2 Pages

  9. Q22PX

    2 Pages

  10. Model Q45P/R

    2 Pages