Product catalog summary
Introduction
The Model A15/79 Total Residual Chlorine Monitor is designed for monitoring chlorine levels in potable water, wastewater effluent, and cooling water to control biological activity. Chlorination ensures safe drinking water, recreational water safety, and reduces biofouling in cooling systems.

Chlorine Measurement
Residual chlorine exists in various forms, and measuring total residual chlorine is essential in systems with mixed chlorine forms. The standard method involves reacting chlorine with potassium iodide at pH 4, releasing iodine, which is then measured.

ATI’s Model A15/79 Features
  • Uses a unique sensing technique with a membraned gas sensor for iodine measurement, enhancing stability by preventing sample contaminants from contacting electrodes.
  • Offers two sensing systems: direct contact gas sensor and air stripping system for highly contaminated samples.
  • Includes an alphanumeric LCD for chlorine display, alarm status, and configuration information.
  • Programmable control relays for setpoint, deadband, and time delay, with multiple control modes.
  • Isolated 4-20 mA output, programmable and invertible.

Operation
The monitor is an automated system that mixes a sample with buffer and potassium iodide. The iodine released is measured using either a direct contact or air stripping method, suitable for low-range measurements in dechlorinated wastewater.

Components
  • Chemistry module for buffer and potassium iodide addition.
  • Inlet flow assembly for raw sample delivery.
  • Electronic readout for chlorine concentration display and alarm contacts.

Specifications
  • Range: 0-2.000 or 0-20.00 PPM
  • Accuracy: ± 0.02 PPM
  • Repeatability: ± 0.01 PPM
  • Operating Conditions: 0-50°C, 0-95% RH non-condensing
  • Power: 110/220 VAC, 50/60 Hz

Installation
Includes a 20 ft. interconnecting cable, extendable to 100 ft. Optional stainless steel system panel available for component mounting.

Ordering Information
Model A15/79 - C - D - E, with options for enclosure type, sensing system, and power supply.
See more

Catalog excerpts

Analytical Technology A15/79 Total Chlorine Monitor-2

Chlorination of potable water, wastewater effluent, and cooling water is widely used throughout the world to control biological activity in the water. Disinfection of potable water with chlorine ensures that tap water is safe to drink once it has passed through the distribution system. Wastewater disinfection helps to ensure that receiving streams are safe for recreational use, and cooling water chlorination reduces biofouling that can degrade heat transfer efficiency. In addition to these common uses, there are many other applications where chlorine addition helps to reduce biological contamination....

 Open the catalog to page 2
Analytical Technology A15/79 Total Chlorine Monitor-3

Gas Phase Sensing: Measurement is made without contact between sample and electrodes, eliminating the potential for sensor fouling. Standard Method: Total chlorine is measured using EPA recommended method of reaction of sample with buffer and potassium iodide, and measurement of iodine released in the reaction. Alphanumeric LCD: Provides residual chlorine display, alarm status indication, and all configuration information. Two Control Relays: Relays are programmable for setpoint, deadband, and time delay. Relays offer pulse frequency and pulse width modulation control modes in addition to simple...

 Open the catalog to page 3
Analytical Technology A15/79 Total Chlorine Monitor-4

Suffix C - Enclosure 1 - Panel Mount 2 - NEMA 4X Wall Mount Suffix D - Sensing System 1 - Contacting Gas Sensor System 2 - Air Stripping Sensor System Suffix E - Power 1 - 120 VAC, 60 Hz 2 - 220 VAC, 50 Hz Options: 00-1261 Stainless steel system mounting plate 31-0037 Sensor interconnect cable (max. 100 ft.) Represented By: Ordering Information: Model A15/79 - C - D - E Total Chlorine Monitor Electronic Monitor Range: 0-2.000 or 0-20.00 PPM Accuracy: ± 0.02 PPM Repeatability: ± 0.01 PPM Linearity: 0.1% of F.S. Zero Drift: < 0.01 PPM per month Display: 16 character alphanumeric backlit LCD Control...

 Open the catalog to page 4

All Analytical Technology catalogs and technical brochures

  1. C12-17

    2  Pages

  2. F12/D

    4  Pages

  3. ChlorLog

    2  Pages

  4. Model Q46H/83

    4  Pages

  5. E12-15 IR

    2  Pages

  6. Metrinet

    4  Pages

  7. Model Q45N

    4  Pages

  8. Q45H/64

    2  Pages

  9. Q45C2

    2  Pages

  10. Q22PX

    2  Pages

  11. Model Q45P/R

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.