Catalog excerpts
FEATURES > Si-PIN Photodiode Օ Thermoelectric Cooler Beryllium Window Օ Hermetic Package (TO-8) Wide Detection Range Օ Easy to Operate Si-PINDetectorFET TemperatureBeWindow Monitor MountingStud2-StageCooler APPLICATIONS > X-Ray Fluorescence Օ OEM Process Control Օ 5.9 keV > 55 Fe > RoHS / WEEE Compliance Portable Instruments Օ Art & Archaeology Teaching & Research Օ Lead Detectors Space and Astronomy Օ Environmental Monitoring Nuclear Plant Monitoring Օ Heavy Metals in Plastic Semiconductor Processing Օ Plating Thickness Sulfur in Oil & Coal Detection Օ Smoke Stack Analysis Coal & Mining Operations Օ Jewelry Analysis Forensic Investigations 6 mm > 2 x 500 M m25.6 M s peaking timeP/B Ratio: 6200/1 > Energy (keV) ICR (kcps) 275250 225 200 175 150 1251 10 100 1,000 Resolution vs. ICR for Dierent Peaking Times > M s, 12 M s, or 20 M s) and the MCA function. The XR-100CR/PX2CR or XR-100CR/PX4 system ensures stable operation in less than one minute from power turn-on. The resolution for the 5.9 keV peak of M s). The PX4 is DC powered by an AC adaptor and provides both a variable Shaping Amplifier (.25 ns to 40 0.8 M s2.4 M s > Model XR-100CR is a high performance X-Ray Detector, Pre-amplifier, and Cooler system using a thermoelectrically cooled Si-PIN Photodiode as an X-Ray detector. Also mounted on the 2-stage cooler are the input FET and a novel feedback circuit. These components are kept at approximately -55հC, and are monitored by an internal temperature sensor. The hermetic TO-8 package of the detector has a light tight, vacuum tight thin Beryllium window to enable soft X-Ray detection. Power to the XR-100CR is provided by either the PX2CR or the PX4. The PX2CR is AC powered and includes a spec- troscopy grade Shaping Amplifier with fixed time constant (6 4.8 M s9.6 M s25.6 > FWHM (@ 5.9 keV) M s > 1,000100101 Throughput for Dierent Peaking Times2.4 0.8 M s M s4.8 > OCR (kcps) M s9.6 > 55 M s25.6 > Fe is 145 eV FWHM to 260 eV FWHM depending on the de- tector type and shaping time constant (see next page for selection guide). M s > 1 10 100 1,000 ICR (kcps) size="-1">
Open the catalog to page 1FeKZnK > Counts Counts Counts
Open the catalog to page 3Counts 109 Cdexcitation source >
Open the catalog to page 4All Amptek Inc. catalogs and technical brochures
-
DP5 Specifications
4 Pages
-
OEM Components
2 Pages
-
XR-100CR Selection Chart
2 Pages
-
GAMMA-RAD
4 Pages
-
XR-100T-CdTe
4 Pages
-
pre amplifier A250
4 Pages
-
DIGITAL PULSE PROCESSOR
4 Pages
-
Miniature X- Ray Source
4 Pages
-
Silicon Drift Detector
4 Pages
-
Complete X- Ray Spectrometer
4 Pages