Catalog excerpts
eV FWHM SD D > Counts 9.6 s peaking time100,000 CPSP/B Ratio: 6,800/1 S D D S D D > Energy (keV) Figure 1. 55 Fe Spectrum with silicon drift detector (SDD). SD D > XR-100SDD Features S D D > HIGH COUNT RATE - >300,000 CPS Օ 136 eV FWHM Resolution High Peak-to-Background Ratio - 6800:1 Օ 7 mm S D D > 2 x 450 m Օ USB Controlled No Liquid Nitrogen SD D S D D > Applications Օ X-Ray Fluorescence RoHS / WEEE Compliance XRF Օ OEM & Special Applications Process Control Օ ResearchThe XR-100SDD and X-123SDD Silicon Drift Detectors (SDD) are the latest additions to Ampteks line of x-ray detectors that revolutionized the industry. Their high performance, small size, and low cost make them the ideal detector for OEM hand-held ap- plications to bench-top analyzers. The silicon drift detector (SDD) enables extremely high count rate applications with excellent energy res- olution. The detector is housed inside the same TO-8 package as AmptekҒs other detectors, so its form-factor is a direct replacement for current systems and is com- patible with all Amptek accessories and options. The Amptek Silicon Drift Detectors (SDD) represent a breakthrough in x-ray detector technology by providing o-the-shelfӔ performance previously available only from expensive cryogenically cooled systems. X-Ray Detector and Digital Pulse Processor with MCA S D D SD D S D D > X-123SDD SD D SD D S D D SD D S D D > Complete X-Ray Spectrometer Includes: 1 Silicon Drift Detector and Preamplier 2 Digital Pulse Processor and MCA 3 Power Supply S D D S D D S D D S D D > AMPTEK Inc. 14 DeAngelo Drive, Bedford, MA 01730-2204 USA Tel:+1 781 275-2242 Fax:+1 781 275-3470 E-mail: sales@amptek.com www.amptek.com SD D >
Open the catalog to page 1Amptek SDD Eciency and Transmission Amptek SDD Eciency and Transmission > 1/3 mil Be 0.8 0.2 1/3 mil Be 1/2 mil Be 1/2 mil Be 1 mil Be 1 mil Be Eciency (log) Total Attenuation Eciency (linear) Photoabsorption Total Attenuation K Ҏ lines of selected elements Photoabsorption O F Ne Na Mg Al Si P S Ar Ca Ti Cr Fe Ni Zn Ge Br Sr Mo Ag Sb Ba Ta Au Pb U Fm 0 1 10 100 1.00.10.010.001Energy (keV) 0 1 10 100 1.00.60.40.0Energy (keV) Figure 7. Eciency (log scale) of 450 ѵm thick SDD and transmission through Be window.Figure 8. Eciency (linear scale) of 450 m thick SDD and trans-mission through Be...
Open the catalog to page 4All Amptek Inc. catalogs and technical brochures
-
DP5 Specifications
4 Pages
-
OEM Components
2 Pages
-
XR-100CR Selection Chart
2 Pages
-
GAMMA-RAD
4 Pages
-
XR-100T-CdTe
4 Pages
-
pre amplifier A250
4 Pages
-
DIGITAL PULSE PROCESSOR
4 Pages
-
Miniature X- Ray Source
4 Pages
-
Complete X- Ray Spectrometer
4 Pages
-
X-RAY DETECTOR
4 Pages