Catalog excerpts

2-Way Sensing Valve Model 4109 - Vibro-Guard Overview AMOT Model 4109 Vibro-Guard Valve is a 2-way acceleration sensing valve with optional electric microswitch. Failing bearings, broken blades, cracked, broken or bent shafts, misfiring, and accumulated deposits are a few of the items which the Vibro-Guard can detect. This unit is weatherproof and corrosion protected for salt spray atmospheres (Gulfproofed). Typical applications l Motors l Engines Model 4109 2-Way Sensing Valve l Pumps l Compressors l Fan drives l Any moving equipment Key benefits l Gulf-proofed finish l Pneumatic and electric versions available l Reliable repeatability l Pneumatic reset/override available
Open the catalog to page 1
2-Way Sensing Valve - Model 4109 Vibro-Guard Operation Model 4109 makes use of a pivoted lever assembly with a high strength, potted magnet near the end opposite the pivot. When the unit is reset, the magnet is thrust toward the steel armature imbedded in the base and is held there by magnetic force plus the force of the loading spring until the inertia of the lever assembly exceeds the holding force of the magnet and spring. When this occurs, the lever assembly snaps to the tripped position and remains there until manually or pneumatically reset. Tripping of the lever assembly allows the...
Open the catalog to page 2
2-Way Sensing Valve - Model 4109 Vibro-Guard Adjustment Vibro-Guard is factory set at approximately 2 G’s in the horizontal position. Should this setting not be suitable for the intended application, an adjustment will be necessary. To adjust the trip point, isolate the Vibro-Guard from the safety circuit and bring the protected machine to its rated speed and load. Remove Cover (47) and check Lever Assembly (24) to see if the unit has tripped. If it has, attempt to reset by firmly pressing the rectangular leaf spring on the lever assembly at Point B (see assembly drawing on the back page)....
Open the catalog to page 3
2-Way Sensing Valve - Model 4109 Vibro-Guard Typical piping diagram This circuit will actuate a Master Safety Control or Pressure Operated Valve upon excessive vibration as detected by the AMOT Model 4109. The Pneumatic Indicating Relay will show the cause of the shutdown and the Model 4057 Valve can be used to remotely rest or override the 4109. PSESSUBE OPERATsD niJLllUHE IHLET AECLSSTDEHTEh I'JPJhG Properly applied and installed, Model 4109 requires practically no maintenance. An inspection of the unit at yearly intervals is adequate to detect and make provision for normal wear. It is...
Open the catalog to page 4
2-Way Sensing Valve - Model 4109 Vibro-Guard Maintenance continued UALWE WITH Mjx\u#,trr SWITCH
Open the catalog to page 5
2-Way Sensing Valve - Model 4109 Vibro-Guard Housing and cover material: Precision cast aluminum black anodized Internal parts: Aluminum or plated steel Standard seals: Viton Maximum operation temperature: 93°C 200°F Maximum valve intlet pressure: 6.2 bar 90 psi Valve capacity (tipped) at 20 psi: 0.09 m3/min 3 scfm Vibration sensing range on horizontal surface 6G
Open the catalog to page 6
AMOT Western Way Bury St Edmunds Suffolk, IP33 3SZ England AMOT USA 8824 Fallbrook Dr Houston, TX 77064 USA Asia and Australasia AMOT Shanghai Rm A8-671 Jiahua Business Center 808 Hongqiao Road Shanghai 200030 China Tel +86 (0) 21 6447 9708 Fax +86 (0) 21 6447 9718 Email shanghai@amot.com AMOT Singapore 10 Eunos Road 8 #12-06 Singapore Post Centre Singapore 408600 Tel +65 6408 6265 Fax +65 6293 3307 Email singapore@amot.com
Open the catalog to page 7All AMOT catalogs and technical brochures
-
IP1-Impact-Transmitter
2 Pages
-
7001 Swing Gate
4 Pages
-
4095 2-Way Vent Valve
1 Pages
-
4395 Electric Trip Switch
4 Pages
-
4103D Temperature Detector
4 Pages
-
1672 Pressure Sensing Valve
7 Pages
-
4047 Pressure Valve
5 Pages
-
Model 8402
6 Pages
-
Model 4123C
5 Pages
-
Model 4418F
9 Pages
-
Model 4420
7 Pages
-
Model 2180
6 Pages
-
XTS-W Bearing Wear Monitor (BWM)
11 Pages
-
SEDM
4 Pages
-
MPD Introduction
12 Pages
-
Control System Solutions
12 Pages
-
Chalwyn Spark Arrestors
4 Pages
-
System Selection Guide
12 Pages
-
Product Selection Guide
20 Pages
-
Intake Air Shutoff Valve
4 Pages
-
Temperature Control Valve
21 Pages
-
Metal Particle Detector
8 Pages
-
2 or 3-Way Pressure Valve
5 Pages