4102D/J and 4102M Temperature Valves and 4102M
8Pages

{{requestButtons}}

Catalog excerpts

4102D/J and 4102M Temperature Valves and 4102M - 1

Temperature Detectors for Moving Bearings Models 4102D, J & M Overview AMOT Model 4102D & J Temperature Valves and Model 4102M Miniature Temperature Valves are ideal for use on medium and high speed engines. The valves initiate a warning or shutdown upon a sudden temperature rise in critical machine parts caused by tight, worn or out-of-round bearings, tight packing glands, cracked or broken shafts, torsional vibration, power or compressor cylinder overload, lack of lubricant flow and many other sources. The 4102M valves provide the same low cost reliability for small bearings that have been field proven by their larger counterparts (Model 4102D & J) in larger stationary bearing applications. Model 4102D & J Temperature Detector Model 6702X Spare Fuse Rod Typical applications l Accurate and reliable in engines used for gas compression, power generation, pipeline, marine and general industrial service l Monitors bearings, shafts and other moving parts for unsafe high temperature levels l Responds to increased bearing temperatures caused by: - Tight, worn or out-of-round bearings - Cracked or broken shafts - Power or compressor cylinder overload - Lack of lubrication fluid - Tight packing glands - Torsional vibration - Mis-alignment - Other sources of temperature rise Model 4102M Temperature Detector Model 7334X Spare Fuse Rod Key features and benefits l Provides early warning of problems - avoids high cost bearing failures l Use with oil, air or gas l Instant response to excessive bearing temperatures l Compact design - easy, low cost installation l Minimal maintenance - low cost of ownership

Open the catalog to page 1
4102D/J and 4102M Temperature Valves and 4102M - 2

Temperature Detectors - Model 4102 AMOT Model 4102 temperature detectors are a safety device suitable for monitoring bearing temperature. A thin film of eutectic alloy (less than 0.01 cubic mm in volume) secures a spring- loaded fuse rod. When the temperature increases, the sensing end melts the alloy and the fuse rod is instantly released moving outwards. Due to their small eutectic mass, the detectors are virtually as responsive as thermocouples. Model 4102 temperature detectors do not require the impractical wiring of electrical sensors. The trip temperature will be between 79°C and...

Open the catalog to page 2
4102D/J and 4102M Temperature Valves and 4102M - 3

Temperature Detectors - Model 4102 Installation Factors • Control pressure source may be clean dry air/gas (for versatile, non-hazardous locations). • Maximum pressure to IN port of the vent valve is 60 psi. • Install the vent valve above the oil level in the sump to facilitate manual re-setting. • Each sensing device should be connected to control pressure lines and piped in series ending with the master safety control/alarm component. • Must NOT be installed with the fuse rod tip • Not recommended for installation where oil may leak along the unsealed fuse rod shaft. • See Fig. 1 or Fig....

Open the catalog to page 3
4102D/J and 4102M Temperature Valves and 4102M - 4

Temperature Detectors - Model 4102 How to order - Model 4102D & J Use the tables below to select the unique specification of your Model 4102D/4102J Temperature Detector: Example Code Basic Model Mounting Thread Code Description Brass Body - Eutectic Alloy Sensor Installed Depth (min - max) *Consult Fuse Rod Selection Chart on page 3 for installed projection length Fuse Rod Length *Consult Fuse Rod Selection Chart on page 3 for installed projection length Trip Temperature Special Requirements

Open the catalog to page 4
4102D/J and 4102M Temperature Valves and 4102M - 5

Temperature Detectors - Model 4102 Dimensions - 4102M Figure 2 Fuse Rod Length Code Selection 4102 M - Fuse Rod Length Code Selection Install Depth Code Projection Length Flush

Open the catalog to page 5
4102D/J and 4102M Temperature Valves and 4102M - 6

Temperature Detectors - Model 4102 How to order - Model 4102M Use the tables below to select the unique specification of your Model 4102M Temperature Detector: Example Code Basic Model Mounting Thread Installed Depth (min - max) Consult Fuse Rod Length Code Selection Table on page 5 for projection length Fuse Rod Length Consult Fuse Rod Length Code Selection Table on page 5 for projection length -AA Code Description Brass Body - Eutectic Alloy Sensor Trip Temperature Special Requirements

Open the catalog to page 6
4102D/J and 4102M Temperature Valves and 4102M - 7

Temperature Detectors - Model 4102 Service Kits Replacement Fuse Rod Assemblies may be ordered from the tables below. Consult the Fuse Rod Length Code Selection tables on pages 3 and 5 for projection lengths. How to Order: Replacement fuse rod for Models 4102D & J Example Code Consult Fuse Rod Length in 'How to Order' table Trip Temperature How to Order: Replacement fuse rod for Model 4102M Example Code Consult Fuse Rod Length in 'How to Order' Table Trip Temperature

Open the catalog to page 7
4102D/J and 4102M Temperature Valves and 4102M - 8

AMOT USA 8824 Fallbrook Dr Houston, TX 77064 USA AMOT Shanghai Rm 4102 - 4104 United Plaza 1468 Nanjing Road West Shanghai 200040 China Europe, Middle East and Africa AMOT Western Way Bury St Edmunds Suffolk, IP33 3SZ England Tel +44 (0) 1284 762222 Fax +44 (0) 1284 760256 Email info@amot.com AMOT Controls GmbH Rondenbarg 25 22525 Hamburg Germany Tel +49 (0) 40 8537 1298 Fax +49 (0) 40 8537 1331 Email germany@amot.com AMOT Russia #34 Shabolovka Street Building 2 Moscow 115419 Russia Tel +7 495 617 12 93 Fax +7 495 913 97 65 Email russia@amot.com