4064 Differential Pressure Valve
5Pages

{{requestButtons}}

Catalog excerpts

4064 Differential Pressure Valve - 1

Differential Sensing Pressure Valve Model 4064 Overview AMOT Model 4064 is used for sensing limits of increasing or decreasing differentials. Some applications include gas compressor installation to shut down the engine in the case of overloading, as well as sensing excessive pressure drop through a filter, indicating filter clogging. Typical applications l Compressor suction l Discharge pressure sensing l Detection of: - Clogs across filters Differential Sensing Pressure Valve l Detecting pump cavitation l Fluid leakage Key features and benefits l Settings from 0.55 - 241 bar (8 - 3500 psi) l Gulfproof, anodized aluminum construction l Accepts hydraulic or pneumatic signals

Open the catalog to page 1
4064 Differential Pressure Valve - 2

Differential Sensing Pressure Valve - Model 4064 Operation At the set differential, safety control system pressure coming into port A will vent out of port B. A typical application would be on a gas compressor installation. The gas discharge line would be connected to port P1, and the suction pressure line would be connected to port P2. If the pressure at P1 exceeded that of port P2 by the set amount, (indicating compressor connecting rod overloading), port A would vent and shut down the engine. Model 4064 is supplied by AMOT with the differential pressure setting compatible for a specific...

Open the catalog to page 2
4064 Differential Pressure Valve - 3

Differential Sensing Pressure Valve - Model 4064 HIGH PRESSURE VALVE INLET VALVE OUTLET SENSING 2 MOUNTING HOLES TAPPED 16 UNC THROUGH BACK OF CASE. CAN TAKE 6mm OD BOLTS Datasheet 4064 Diff Pressure Valve 0311 Revl

Open the catalog to page 3
4064 Differential Pressure Valve - 4

Differential Sensing Pressure Valve - Model 4064 How to order Use the table below to select the unique specification of your 4064 Differential Sensing Pressure Valve: Since there are several variables in these units, we request that the customer supplies the exact operating characteristics. In order to see whether the desired differential is obtainable, proceed as follows (refer to the Model Code Table below): Please specify: a. Port No. and Pressure of Fixed Port b. Port No. and Pressure at which Variable Port trips and whether on increasing or decreasing pressure 1. Model No....

Open the catalog to page 4
4064 Differential Pressure Valve - 5

AMOT USA 8824 Fallbrook Dr Houston TX 77064 USA AMOT Western Way Bury St Edmunds Suffolk, IP33 3SZ England Asia and Australasia AMOT Shanghai Rm A308 Building A8 Jiahua Business Center 808 Hongqiao Road Shanghai 200030 China Tel +86 (0) 21 6447 9708 Fax +86 (0) 21 6447 9718 Email shanghai@amot.com AMOT Singapore 10 Eunos Road 8 #12-06 Singapore Post Centre Singapore 408600 Tel +65 6408 6265 Fax +65 6293 3307 Email singapore@amot.com

Open the catalog to page 5