Catalog excerpts

Low Pressure Valve Model 4047 Overview AMOT Model 4047 is used as a 2-way or 3-way high capacity, low pressure valve for settings from 0.007 bar (0.1) psi falling to 0.77 bar (11.2 psi) rising over several ranges. Applications include sensing low pressure low pressure gas, water, fuel, oil, or for liquid level sensing and control. By piping to the vacuum port, the valve can be used to sense vacuum pressure from 0.007 bar (0.1) psi falling. The 4047 can detect overload on gas engines by sensing the vacuum pressure in the intake manifold. Typical applications • Sense low pressure or vacuum of water, air, natural gas, oil and more Detection of overload on gas engines Sensing of vacuum intake air manifold 3-way valve has balanced force design Pressure can be applied at any port Buna N (Nitrile) “tadpole” seals are easily replaced Bubble-tight seals with center dead spot (no port overlap) Gulfproof finish standard
Open the catalog to page 1
Low Pressure Valve - Model 4047 Valve to open on rising pressure Port 1 must be plugged. Rising pressure will open Port 2 to Port 3 above the trip point. Valve to open on falling pressure Port 3 must be plugged. Falling pressure will open Port 2 to Port 1 below the set trip point. Valve operation for 3-way action is identical with that for 2-way except that there will be no plugged diaphragm housing Valve spool diaphragm Buna N (Nitrile) Maximum operating ports. On valves set to trip on rising pressure, Port 1 will open to Port 2 until just below the trip point. Port 3 will open to Port 2...
Open the catalog to page 2
Low Pressure Valve - Model 4047 MOUNTING BRACKET Use the tables below to select the unique specification of your 4047 Low Pressure Valve: Datasheet 4047 Low Pressure Valve 0513 Revl
Open the catalog to page 3
Low Pressure Valve - Model 4047 Maintenance Properly applied and installed, Model 4047 requires minimal maintenance. Unless leakage or other problems are noticed sooner, an inspection of the units at yearly intervals is adequate to detect and make provision for normal wear and preventative maintenance. It is recommended that the valve be checked monthly if possible for proper functioning by simulating an unsafe condition. Service kits STAMP "P" Seal ring Seal ring
Open the catalog to page 4
Europe, Middle East, Africa AMOT USA 8824 Fallbrook Dr Houston TX 77064 USA AMOT Western Way Bury St Edmunds Suffolk, IP33 3SZ England Asia Pacific AMOT Controls GmbH Rondenbarg 25 22525 Hamburg Germany AMOT Shanghai Rm 4102 - 4104 United Plaza 1468 Nanjing Road West Shanghai 200040 China
Open the catalog to page 5All AMOT catalogs and technical brochures
-
IP1-Impact-Transmitter
2 Pages
-
7001 Swing Gate
4 Pages
-
4095 2-Way Vent Valve
1 Pages
-
4395 Electric Trip Switch
4 Pages
-
4103D Temperature Detector
4 Pages
-
1672 Pressure Sensing Valve
7 Pages
-
4109 Vibration Sensor
7 Pages
-
Model 8402
6 Pages
-
Model 4123C
5 Pages
-
Model 4418F
9 Pages
-
Model 4420
7 Pages
-
Model 2180
6 Pages
-
XTS-W Bearing Wear Monitor (BWM)
11 Pages
-
SEDM
4 Pages
-
MPD Introduction
12 Pages
-
Control System Solutions
12 Pages
-
Chalwyn Spark Arrestors
4 Pages
-
System Selection Guide
12 Pages
-
Product Selection Guide
20 Pages
-
Intake Air Shutoff Valve
4 Pages
-
Temperature Control Valve
21 Pages
-
Metal Particle Detector
8 Pages
-
2 or 3-Way Pressure Valve
5 Pages