Pressure Sensing Valve - Model 4023 Overview AMOT Model 4023 can be used as a 2 or 3-way capacity, pressure sensing valve. This valve is ideal for applications that require compressor suction and discharge pressure sensing at high pressure levels. Dual purpose construction provides a wide latitude of applications and permits easy field adjustment or changeover from trip on falling to trip on rising pressure. Trip settings are adjustable in eight ranges from 1.2 bar (18 psi) falling to 524 bar (7600 psi) rising pressure. The 4023 valve is suitable for use on air, hydraulic, or gas control systems with control systems pressure up to 8.6 bar (125) psi. Typical applications • Well head control • Actuator piloting valve • Suction/discharge pressure Key features and benefits • Setting to 524 bar (7600 psi) • 2 or 3-way action • Balanced 3-way valve - pressure can be applied to any port • 3-way valve suitable for LP gases, natural gas, oil, air etc • Bubble-tight seals with center dead spot (no port overlap) • Field adjustable - rising or falling • Adjustable setpoint • Gulfproof finish standard
Open the catalog to page 1Pressure Sensing Valve - Model 4023 Operation The 3-way valve has a pressure–actuated, spring return operator. Without pressure applied to the sensed pressure port, Port 3 is open to Port 2. With pressure applied to the sensed pressure port, Port 3 closes before Port 1 opens to Port 2. A small dead spot on the center of the stroke prevents valve port overlap. The valve is normally set at the factory so that Port 1 just opens to Port 2 on a pressure rise to the specified tripping pressure setting. The valve is converted to 2-way action by plugging Port 1 or Port 3. A manual reset feature is...
Open the catalog to page 2Pressure Sensing Valve - Model 4023 Installation continued Position Adjusting part opening Lever position standard valves pneumatic reset rising pressure. [Risrig Pressure Only) Pressure Range Codes 5 & 6. Pressure Range Properly applied and installed 4023 valves require minimal maintenance. Unless leakage or other problems are noticed earlier, an inspection of the units at yearly intervals is adequate to detect and make provision for normal wear and preventive It is recommended that Model 4023 be checked monthly for proper functioning by simulating an unsafe condition. AMOT designs and...
Open the catalog to page 3Pressure Sensing Valve - Model 4023 How to order Use the tables below to select the unique specification of your 4023 Pressure Sensing Valve: B Port Threads and Finish Buna N (Nitrile) for pressure ranges 1 and 2 Viton for pressure ranges 1 and 2 Viton for pressure ranges 3 to 8 Anodized (Gulfproof) Pneumatic (Special Order)
Open the catalog to page 4Pressure Sensing Valve - Model 4023 Dimensions Manual reset after trip on rising or falling pressure 1.1 [28.6] Pneumatic reset only after trip on rising pressure 3 Ports 1/4” - NPT 0.8 [20.6] 2 Mounting holes tapped 3/8 - 16 N.C. through back of Case. Can take 1/4” O.D. bolts. Sensed Pressure Port 1/4 - NPT Pipe Thread 7.1 [179.4] Note: Drain hole may be rotated 360°. Pressure Range Codes 7 and 8 only Drain 1/8” - NPT Pipe Thread Pressure Range Codes 3-8 only
Open the catalog to page 5Europe, Middle East, Africa AMOT USA 8824 Fallbrook Dr Houston TX 77064 USA AMOT Western Way Bury St Edmunds Suffolk, IP33 3SZ England Asia Pacific AMOT Shanghai Rm 4102 - 4104 United Plaza 1468 Nanjing Road West Shanghai 200040 China Tel +86 (0) 21 6279 7700 Fax +86 (0) 21 5237 8560 Email shanghai@amot.com AMOT Singapore 10 Eunos Road 8 #12-06 Singapore Post Centre Singapore 408600 Tel +65 6408 6265 Fax +65 6293 3307 Email singapore@amot.com
Open the catalog to page 6All AMOT catalogs and technical brochures
-
IP1-Impact-Transmitter
2 Pages
-
7001 Swing Gate
4 Pages
-
4095 2-Way Vent Valve
1 Pages
-
4395 Electric Trip Switch
4 Pages
-
4103D Temperature Detector
4 Pages
-
1672 Pressure Sensing Valve
7 Pages
-
4047 Pressure Valve
5 Pages
-
4109 Vibration Sensor
7 Pages
-
Model 8402
6 Pages
-
Model 4123C
5 Pages
-
Model 4418F
9 Pages
-
Model 4420
7 Pages
-
Model 2180
6 Pages
-
XTS-W Bearing Wear Monitor (BWM)
11 Pages
-
SEDM
4 Pages
-
MPD Introduction
12 Pages
-
Control System Solutions
12 Pages
-
Chalwyn Spark Arrestors
4 Pages
-
System Selection Guide
12 Pages
-
Product Selection Guide
20 Pages
-
Intake Air Shutoff Valve
4 Pages
-
Temperature Control Valve
21 Pages
-
Metal Particle Detector
8 Pages
-
2 or 3-Way Pressure Valve
5 Pages