Overview: The document provides comprehensive technical specifications and operational details for the J1905S alarm panel, designed for high-security installations. It highlights features such as dual redundant power supply, input selection, and alarm processing functions.
Specifications:
  • Format: DIN 96 x 96
  • Power Supply: 15-65Vac/dc or 80-265Vac/dc with 4KV galvanic insulation
  • Inputs: 8 inputs with LED indicators, selectable as simple indicators or alarms
  • Outputs: 8 open collector outputs, synthesis relay, and sound alarm relay
  • LED Display: 7 color options, adjustable brightness
Key Features:
  • Alarm Processing: Configurable channels for indication or alarm treatment, with delay times and input contact direction options.
  • Redundant Power Supply: Dual power sources with automatic switching for continuous operation.
  • Input Selection: Configurable for positive or negative input types.
  • Security Features: Watchdog function to disable relays during system shutdown or power loss.
Operational Procedures:
  • LED Test and Reset: External buttons for testing LEDs and resetting alarms.
  • Inhibition Function: Allows selective channel inhibition for managing alarms during specific conditions.
  • Output Connections: Instructions for connecting outputs with overcurrent protection.
Recommendations:
  • Ensure proper configuration of input types and relay selections.
  • Utilize the inhibition function during non-critical periods.
  • Regularly test LED functionality and reset mechanisms.
Technical Alarm Centralization System Overview: The J3000/J3105 series are sequence panels for technical alarm centralization, managing and displaying alarm states through visual and auditory signals.
Functionality and Main Characteristics: Detects changes in input states, triggering LED blinking and activating sound and synthesis outputs. Reset is performed step-by-step via push buttons.
Input and Output Configuration: Supports NO and NC inputs, with adjustable delay times. Outputs can activate based on input activation or LED status.
Switch and Button Functions: Rear switches allow for program selection and input configuration. Front panel buttons manage sound alarms and LED states.
Alarm Sequence Types: Two sequence types differentiate between first and subsequent alarms using fast and slow blinking modes.
Fault and Indicator Management: Handles fault avalanches, identifying the first alarm for rapid troubleshooting.
Terminal and Connection Details: Outlines use of terminals for input and output connections, including positive and negative input configurations.
Conclusion: The J3000/J3105 series offers flexible configuration options and robust fault management capabilities, ensuring clear differentiation of alarm states.
Specifications: The J3500 alarm panel system includes various input and output configurations, synchronization capabilities, and relay options. It supports both positive and negative input configurations.
Procedures: Includes a test function for sequentially activating channels and outputs, and a reset function via terminal or front panel button.
Standards and Recommendations: Supports synchronization across multiple panels and recommends galvanic isolation for relay outputs.
Key Features: Supports RS232 and optional RS485/422 connections, includes a display for operating status, and can be expanded with additional software.
Application Example: Describes connecting multiple panels with synchronized blinking LEDs and centralized control.
Technical Specifications: Power supply options range from 14Vdc to 260Vac/dc, operating temperature range of -10°C to +50°C, and includes a DIN 144x144 format.
Accessories: Lists various accessories, including relay cards for DIN rail mounting and sealed fronts for enhanced protection.
See more

Catalog excerpts

Alarm Annunciators-1

ANNUNCIATORS Range Technical Alarm J3000/J3105 PANEL’PC Bus Alarms Centralization

 Open the catalog to page 1
Alarm Annunciators-2

Realized by the company «TIME» (France) Realized by the company «Kautz StarkstromAnlagen GmbH» (Germany) 3, Rue de la Garenne - Z.I. de Vernon 27950 SAINT MARCEL - FRANCE tél. : +33 (0)2 32 51 47 16 Fax : +33 (0)2 32 21 13 73 http://www.ami-control.com  : [email protected]

 Open the catalog to page 2
Alarm Annunciators-3

Dual security power supply Positive and negative inputs (Extension of the J1905 with redundant power supply) «General alarm» relay selection Inputs selection «Positive or négative» Fuse Voltage presence LED «LEDs test» button «Reset» button REAR VIEW This panel is designed for installations with «high security». It includes all the capabilities of J1905, added to : - Single or double permanent power supply, with automatic switching from one to the other in case of failure. - Inputs can be activated by a contact connected to the «+» or to «-» (open collector contact or contact connected to ground)....

 Open the catalog to page 3
Alarm Annunciators-4

A channel can be «positive input» or «negative input». The selection is made with S6 at the back of the panel. Contact direction: the direction of contact (NO / NC) is selected with the S3 switch. Caution : in case of a channel selected by S6 in negative input, the S3 selection becomes reversed. Indicator / Alarm Selection External «LEDs Test» External «Reset» «Synthesis» relay selection «LEDs Test» The microprocessor is provided with a «Watchdog» that disables the «synthesis» relay and «Sound alarm» relay in case of system shut-down or in case of loss of one of the two power supplies. The «Sound...

 Open the catalog to page 4
Alarm Annunciators-5

INPUTS CONNECTIONS : Connection diagram for J1905S with negative inputs Connection diagram for J1905S with positive inputs (contacts connected to the frame) The «Leds Test», «RESET», «Inhibition» Inputs must always be connected to the «+ COM». +/~ Automaton output card +/~ Automaton output card Input by «External Voltage» : Maximum voltage on input: 65 Vac / dc. In other cases, use the diagram «dry contact input.» In case where the input is powered by an external voltage (e.g. open collector controller card) it is necessary to interconnect the «-» of external electronic with the J1905S terminal...

 Open the catalog to page 5
Alarm Annunciators-6

J1905S FRONT FACE : «Voltage presence» indicator : A «voltage presence» LED is present on the front face. It lights green when all power supplies present are active. In the case of loss of one of the power supplies, the Led will become flashing red. It will go to orange fixed when the «blocking» terminal will be activated. «LED Test» button : A «test led» button is available on the front face. A rear terminal allows to connect an external button (closing contact, it must be connected to the «+ COM») which will provide «LED test» on several panels at once. RESET button LEDs Test button RESET or...

 Open the catalog to page 6
Alarm Annunciators-7

LED LUMINOSITY ADJUSTMENT : - LED luminosity can be adjusted using a connected external potentiometer between terminals 1 and 2 of J rear connector by rapid connection. - No potentiometer => maximum luminosity. - With potentiometer 1 to 5 kOhm => adjustments. Dimming Command Rear terminal External Potentiometer OUTPUT FOR EXTERNAL BUZZER : An external buzzer (10mA maximum, Voltage 12Vdc) can be connected to terminal 3 and 4 of J connector respecting polarity «+» on terminal 3. (But it is better to use the contact of RKL relay). External Buzzer POWER SUPPLY / DUAL POWER SUPPLY : Depending on the...

 Open the catalog to page 7
Alarm Annunciators-8

PRODUCING LABELS : Labels are ordinary paper sheets that can be slid into a transparent pocket included in the thickness of the front face. A blank label is supplied with each unit. Labels can be handmade, or draw the screen of the PC and produced on a colour printer (laser or ink-jet). The PC software allows to create labels including images, allows to save and duplicate the achievements. This PC software is FREE. It is possible to load it on our website : www.ami-control.com For high humidity countries, the printing on plastic sheets is recommended. SETTINGS : Potentiometers Time delay adjustment...

 Open the catalog to page 8
Alarm Annunciators-9

MAIN CHARACTERISTICS : 02 Version 15-65Vac/dc Used in « Positive Inputs» : (Positive Inputs, Open contacts) - Consumption min. - Consumption max. (8 channels active) - Consumption 1 card 8 output relays - Consumption on input - High Threshold Used in « Negative Inputs» : (Negative Inputs, Closed contacts) - Consumption min. - Consumption max. (8 channels active) - Consumption 1 card 8 output relays - High Threshold Relay «General Alarm» Technical Alarm Line resistance allowed on contact input (with «+ COM») «Sound Alarm» Relay Buzzer output Protection without front cover Protection with front...

 Open the catalog to page 9
Alarm Annunciators-10

ADDITIONAL PRODUCTS : M0810 Front plate 19-inch, brushed aluminium Ht : 3U Front for bay 4 pre-drilled holes 92x92mm. M0816 Closing cover Closing cover for mounting on M0810 front plate. M0722, IP54 sealed front «Quarter-turn» closing button DIN format 96x96. IP54 sealed front that is fitted directly to product front. An O-ring provides sealing between steel cabinet and panel. The front is a transparent openning door. M0731 Adapter to mount on DIN Rail profil TS35. 96x96 format. This kit allows to mount panels with 96x96 format on a DIN rail TS35 retaining the display towards the operator. M0722...

 Open the catalog to page 10
Alarm Annunciators-11

WALL CABINET ALARM With single or redundant power supply Allows a wall display of all information with and without memory and reset, with or without audible alarm. This economic wall-mounted cabinet displays states and alarms of a installation. It’s equipped with the J1905S (redundant power supply). The J1905S also allows to receive the input contacts with a positive voltage or negative voltage (open collector). It includes : - A buzzer is mounted on the bottom outside the cabinet in order to increase its effectiveness. - A selectable general contact for postponement, and 8 outputs corresponding...