EX1000 Series

EX1000 Series
1 / 16 PagesView full catalog

EX1000 Series

Product catalog summary
Overview
The EX1000 Series by VTI Instruments is a high-density, compact data acquisition system designed for precision and reliability. It features LXI™ LAN connectivity, integrated signal conditioning, and supports various transducer types such as thermocouples, voltages, RTDs, thermistors, frequency, strain, and pressure. The series is scalable, allowing expansion from tens to thousands of channels, and includes a DC version for proximity to test articles. Self-calibration and web-based access enhance usability.
Specifications
The EX1000 Series supports a wide range of transducer types with independent signal conditioning paths and software-selectable filters. It offers end-to-end self-calibration for each signal path, ensuring accuracy despite drift or temperature variations. The instruments are scalable for synchronized high-speed, high-channel count applications and feature open transducer detection for channel status monitoring.
Signal Conditioning and Protection
The EX10SC modular platform extends the EX1000's capabilities, supporting various transducer types on a per-channel basis. It provides exceptional input protection and isolation, suitable for environments with high electrical noise or transient power surges. Supported inputs include thermocouples, RTDs, thermistors, potentiometers, strain gages, pressure, high-level voltage, frequency, and current.
Installation and Control
The EX1000 Series is fully LXI™ compliant, facilitating distributed measurements and reducing cabling costs. It connects directly to LAN networks and features a web-accessible user interface for easy setup and control. The EXlab software provides a programming-free setup, data logging, and measurement display.
Environmental Specifications
The instruments operate within a temperature range of -5°C to +55°C for AC models and -10°C to +65°C for DC models, with storage temperatures from -40°C to +70°C. They conform to MIL-PRF-28800F standards for shock and vibration, supporting operation up to 3000 meters in altitude.
Model Selection
The series includes models like EX1000A, EX1000A-TC, EX1016A, EX1032A, and EX1048A, each with varying channel capacities and input types. The EX10SC module offers additional signal conditioning capabilities with 16-channel capacity and 1500Vrms isolation.
Technical Specifications
  • Input Range Limits: -200 °C to +850 °C for 100 Ω Pt sensors.
  • Input Resistance: Normal at 50 MΩ, Power Off and Overload at 200 kΩ.
  • Input Protection: Continuous protection at 240 V AC, transient protection according to ANSI/IEEE C37.90.1.
  • Sensor Excitation Current: 0.25 mA.
  • Lead Resistance Effect: ±0.005 °C/Ω.
  • Common Mode Voltage (CMV): 1500 Vrms max.
  • Stability: Offset ±20 ppm/°C, Gain ±50 ppm/°C.
  • Noise: Output noise at 100 kHz is 200 μVrms.
  • Bandwidth: -3 dB at 3 Hz.
  • Response Time: 90% span in 150 ms.
RTD Standards
  • 100 Ω PT with an alpha coefficient of 0.00385, compliant with DIN 43760, JIS C 1604-1989, and IEC 751 standards.
Model Specifications
  • EX10SC-8B38-01: Full Bridge Strain with 3.33V Excitation.
  • EX10SC-8B38-02: Full Bridge Strain with 10V Excitation.
  • EX10SC-8B41 Series: Various voltage input models with 1 kHz bandwidth.
  • EX10SC-8B45 Series: Frequency input models ranging from 0 to 100 kHz.
  • EX10SC-8B47 Series: Linearized thermocouple types J, K, and T with specific input ranges and accuracies.
Ordering Information
  • Includes various models such as EX1000A, EX1016A, EX1032A, and EX1048A, each designed for specific input types and ranges.
  • Accessories include rack mount kits and interconnect cables.
See more

Catalog excerpts

EX1000 Series-1

©2014 VTI Instruments Corporation. All rights reserved. EVERY TIME

 Open the catalog to page 1
EX1000 Series-2

OVERVIEW A CC U R AT E . P O W E R F U L . E A S Y TO U S E . The EX1000 family of LXI™ instruments are the most advanced, full-featured data acquisition solutions available on the market today. These scalable, standalone instruments provide superior measurement accuracy and repeatability thanks to fully integrated signal conditioning, advanced cold junction compensation (CJC), and end-to-end self-calibration. The EX1000 family of data acquisition instruments addresses your most demanding distributed measurement applications in one easy-to-use package. F L E X I B L E C H A N N E L C O N F I...

 Open the catalog to page 2
EX1000 Series-3

EX1000 Series EX1000A • EX1000A-TC/TCDC • EX1016A EX1032A • EX1048A • EX10SC EX10SC HIGHLIGHTS 16-Channel capacity Mix and match transducer types on a per-channel basis CO L D J U N C T I O N CO M P E N S AT I O N The heart of any truly accurate thermocouple measurement system is the CJC implementation. These instruments combine multiple precision thermistors, a significant thermal mass, and careful parts placement to provide world-class measurement performance. Seamless integration with the EX1000A, EX1016A and EX1032A Simplified, reliable The EX10SC modular signal conditioning platform expands...

 Open the catalog to page 3
EX1000 Series-4

EX1000 Series EX1000A • EX1000A-TC/TCDC • EX1016A EX1032A • EX1048A • EX10SC Challenging measurement environments, such as areas with high levels of electrical noise or transient power surges, require unique protection capabilities. The EX10SC signal conditioning platform provides exceptional input protection and isolation across a wide range of operating conditions, protecting valuable instrumentation and ensuring measurement integrity. Simply match the signal characteristics with the appropriate signal conditioning module, make connections with the easy-to-use termination access points, and...

 Open the catalog to page 4
EX1000 Series-5

Precision, Scalable Measurement Instruments LXI Synchronization Technology Mini-T/C connectivity Open thermocouple indication 19”, 1U configuration Power indication LAN/LXI status LEDs Standard LAN connectivity Digital alarm outputs Precision hardware handshaking NIST field calibration capable EX1048A REAR VIEW Precision voltage and thermocouple D-sub connectivity for voltages Mini-T/C connectivity for thermocouples EX1016A FRONT VIEW Single cable access for up to 16 channels of independent signal conditioning inputs 16-channel signal conditioning chassis Individually configurable per channel...

 Open the catalog to page 5
EX1000 Series-6

CHANNEL TYPES SAMPLING RATE TEMPERATURE RESOLUTION TEMPERATURE ACCURACY See Thermocouple Accuracy table on page 5 TEMPERATURE NOISE, PEAK-TO-PEAK PROGRAMMABLE FILTERS *Note: fluctuations for main voltage to the power supply not exceeding VOLTAGE RESOLUTION VOLTAGE ACCURACY ±(0.025% + 500 μV) with self-cal, ±(0.05% + 1 mV) without self-cal ±(0.025% + 50 μV) with self-cal, ±(0.05% + 100 μV) without self-cal ±(0.025% + 10 μV) with self-cal, ±(0.05% + 20 μV) without self-cal ±(0.025% + 10 μV) with self-cal, ±(0.05% + 20 μV) without self-cal ±(0.050% + 10 μV) with self-cal, ±(0.10% + 20 μV) without...

 Open the catalog to page 6
EX1000 Series-7

EX1000A/16A/32A/48A/TC/TCDC Specifications L X I S P E C I F I C AT I O N S CLOCK SPECIFICATIONS Clock oscillator accuracy Synchronization accuracy Reports “synchronized” when < ±200 μs of the 1588 master clock Timestamp Accuracy As good as time synchronization down to 50 ns IEEE 1588-BASED TRIGGER TIMING Alarm Trigger time accuracy As good as time synchronization down to 50 ns Time to trigger delay Receive LAN[0-7] Event Trigger time accuracy As good as time synchronization down to 50 ns Time to trigger delay Future timestamp Past/zero timestamp HARDWARE TRIGGER TIMING LXI Trigger Bus Time to...

 Open the catalog to page 7
EX1000 Series-8

Conditions • 60-minute warm-up • Guaranteed maximum limits are two times (2x) the typical values • 7 days, ±5 °C from last self-calibration • 20 °C to 30 °C, 1 year from full calibration • Exclusive of thermocouple errors • Exclusive of noise • Common mode voltage = 0 Note for K type: 1400 accuracy is for 1372 °C Note for T type: 50

 Open the catalog to page 8
EX1000 Series-9

EX10SC Signal Conditioning Module Specifications EX10SC-8B32-02 INPUT RANGE INPUT RESISTANCE Normal Power Off INPUT PROTECTION Continuous Transient CMV, INPUT TO OUTPUT TRANSIENT, INPUT TO OUTPUT CMR (50HZ OR 60HZ) NMR ACCURACY LINEARITY STABILITY Offset Gain NOISE Output BANDWIDTH, –3 dB RESPONSE TIME, 90% SPAN INPUT RANGE LIMITS Input Range Accuracy INPUT RESISTANCE Normal Power Off Overload INPUT PROTECTION Continuous Transient SENSOR EXCITATION CURRENT LEAD RESISTANCE EFFECT CMV, INPUT TO OUTPUT TRANSIENT, INPUT TO OUTPUT CMR (50 OR 60Hz) NMR ACCURACY STABILITY Offset Gain NOISE Output, 100...

 Open the catalog to page 9
EX1000 Series-10

EX10SC Signal Conditioning Module Specifications EX10SC-8B36-04 INPUT RANGE INPUT RESISTANCE Normal Power Off Overload INPUT PROTECTION Continuous Transient SENSOR EXCITATION CURRENT 10 kΩ Sensor LEAD RESISTANCE EFFECT Ω/Ω; 10 kΩ Sensor CMV, INPUT TO OUTPUT TRANSIENT, INPUT TO OUTPUT CMR (50 OR 60Hz) NMR ACCURACY LINEARITY STABILITY Offset Gain NOISE Output, 100 kHz BANDWIDTH, –3 dB RESPONSE TIME, 90% SPAN 50 MΩ 200 kΩ 200 kΩ 240 V AC ANSI/IEEE C37.90.1 0.25 mA; 100 Ω, 500 Ω, 1 kΩ Sensor 0.10 mA; ±0.01 Ω/Ω; 100 Ω, 500 Ω, 1 kΩ Sensor, ±0.02 1500 Vrms max ANSI/IEEE C37.90.1 120 dB 70 dB at 60 Hz...

 Open the catalog to page 10
EX1000 Series-11

EX10SC Signal Conditioning Module Specifications EX10SC-8B35-04 INPUT RANGE LIMITS –200 °C to +850 °C (100 Ω Pt) INPUT RESISTANCE Normal 50 MΩ Power Off 200 kΩ Overload 200 kΩ INPUT PROTECTION Continuous 240 V AC Transient ANSI/IEEE C37.90.1 SENSOR EXCITATION CURRENT 0.25 mA LEAD RESISTANCE EFFECT ±0.005 °C/Ω CMV, INPUT TO OUTPUT 1500 Vrms max TRANSIENT, INPUT TO OUTPUT ANSI/IEEE C37.90.1 CMR (50 OR 60Hz) 120 dB NMR 70 dB at 60 Hz STABILITY Offset ±20 ppm/°C Gain ±50 ppm/°C NOISE Output, 100 kHz 200 μVrms BANDWIDTH, –3 dB 3 Hz RESPONSE TIME, 90% SPAN 150 ms 100 Ω PT Input Range 0 °C to +600 °C...

 Open the catalog to page 11

All AMETEK VTI Instruments catalogs and technical brochures

  1. EX2500A

    2  Pages

  2. CT-400

    5  Pages

  3. CT-310A

    2  Pages

  4. CT-100C

    2  Pages

  5. SM7000D

    2  Pages

  6. RX0224

    5  Pages

  7. RX0124

    8  Pages

  8. RX0424

    6  Pages

  9. RX1032/RX1000

    5  Pages

  10. SMP1100/1200

    1  Page

  11. EX1629-001

    7  Pages

  12. EX1200 series

    27  Pages

  13. EMX-1434

    10  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.