Sorensen XG 1700 Series
6Pages

{{requestButtons}}

Catalog excerpts

Sorensen XG 1700 Series - 1

1700 Watt, 1U Programmable DC Power Supplies • Industry Leading Power Density – Up to 1700 Watts in 1U • Standard Digital Interfaces – USB&RS232/485 • LXI Ethernet and Isolated analog interfaces • Power Factor Correction-PFC and universal AC input • “Green” Sleep Mode – Automatically “sleeps” after period of non-use • Built in sequencing - Unload your system controller • Programmable fold-back protection delay The XG 1700 is an industry leading programmable DC power supply designed for test, production, laboratory, OEM and quality assurance applications. The XG 1700 is a 1700 Watt, 1U programmable power supply with constant voltage and constant current modes, automatic cross-over and numerous features enabling cost effective, easy integration. Key Features Easy Integration XG 1700 has many control and indication signals such as shutdown, constant voltage (CV) vs. constant current (CC) mode indication, OVP, OCP, OTP, and so on. In addition, the logical-high or -low is free selectable. Thus enabling the XG 1700 to replace existing power supplies with little or no system engineering required. Free selectable analog control range Most DC power supplies provide a 0 to 5 or 0 to 10 V analog control range to control the DC output from zero to full DC output range. With the XG 1700, the analog control range is free selectable starting at 0V to an upper range between 2V and 10V. In other words, the analog programming interface range is freely adjustable. Auxiliary DC output channels with control In many ATE systems one or more low power, fixed voltage supplies are needed to provide electrical power for any periphery within the ATE cabinet. For this purpose, the XG 1700 provides two standard auxiliary DC output channels. Both auxiliary power channels are controllable directly from the front-panel or through SCPI commands. With these channels, it is possible to drive outputdisconnect or polarity-reversal relays, without needing a complicated computer controlled relay board. DC-waveforms through internal sequencing To allow for extremely fast programming, sequences can be programmed into and stored in memory using standard SCPI commands through USB, RS-232/485, LXI or GPIB. Variable Fan Speed Control The XG 1700’s innovative approach to fan speed is determined by internal heat sink temperature. This allows the fans to adjust to a constant optimal speed when the output of the supply is being pulsed. This also reduces noise and increases fan life. Power Saving Standby Mode When the XG 1700 has been in an idle state, the supply can go into “sleep mode”, much like a computer monitor. This will allow the user to save energy and minimize lab noise. Since an XG 1700 left in sleep mode is still “on” the user will have quicker access to an enabled output. Key Modes Output Auto Start Mode (Auto Restart) The Auto Start mode establishes the state of the output of the power supply after recovery from a complete power cycle (all front panel LEDs are not illuminated), or after recovery from a PC failure or reboot. If Auto Start mode is set to On, the power supply output will return to its previous value. Also, after the loss of any remote digital control, the XG unit will remain active in its last programmed setting and will not disrupt any test process. Auxiliary Auto Start Mode The Auxiliary Auto Start mode determines the state of the auxiliary output after a complete power cycle (all front panel LEDS are not illuminated). With Auxiliary Auto Start mode turned to On, the auxiliary output will be activated after the power supply is powered up again. AMETEK Programmable Power 9250 Brown Deer Road San Diego, CA 92121-2267 USA Foldback Mode Foldback mode is used to disable the output when a transition is made between the operating modes. The power supply will turn off/disable the output and lock in foldback mode after a specified delay if the power supply transitions into CV mode or into CC mode, depending on the foldback mode settings. This feature is particularly useful for protecting current or voltage sensitive loads. Foldback can be set to trigger a switch when transitioning from CV to CC mode or from CC to CV mode. sales@ProgrammablePower.com

Open the catalog to page 1
Sorensen XG 1700 Series - 2

XG 1700 Series : Product Specifications Output Output Voltage 1 Line Regulation Voltage Line Regulation Current Load Regulation Voltage Load Regulation Current (0.005% of rated output voltage +2 mV) 4 (0.01% of rated output current +2 mA) 5 (0.005% of rated output voltage + 2 mV) 6 (0.02% of rated output current +5 mA) 7 Minimum output voltage is guaranteed to be ≤ 0.2% of the rated voltage at zero output setting. Minimum output current is guaranteed to be ≤ 0.4% of the rated current at zero output setting when measured with rated load resistance. Total output power is also based on AUX1...

Open the catalog to page 2
Sorensen XG 1700 Series - 3

XG 1700 Series : Product Specifications Maximum Recommended Remote Sense Line Drop Compensation per Line 9 Up-prog. Response Time, 0~Vmax Down-prog. Response Time: Full Load* Down-prog. Response Time: No Load* Over-Voltage Trip Point 9. When using remote sense, the total of the load voltage and the load line drops must not exceed the rated output of the power supply. For example, for an XG 6-220 in an application with 1 V of load line loss (0.5 V/Line), the maximum available load voltage would be 6-1=5 V. Note: The unit may operate at higher output voltages than this, but there is no...

Open the catalog to page 3
Sorensen XG 1700 Series - 4

XG 1700 Series : Product Specifications AC Line Input Specifications Rated AC Input Voltage/Frequency Operational AC Input Voltage/Frequency 85–265 Vac continuous, 47–63 Hz, single phase Power Factor Correction 0.99@100/200 Vac, rated output power Programming Mode Voltage & Current Output Voltage Programming Voltage & Current Output Resistive Programming Voltage Output Resistor Programming Output Voltage and Current Monitor Voltage Programming Accuracy (mV)1 ± 0.5% of rated output voltage, max (0-4V/4K range) ± 0.1% of rated output voltage Current Programming Accuracy (mV)1 ± 1% of rated...

Open the catalog to page 4

All AMETEK Programmable Power catalogs and technical brochures

  1. asterion_ac

    21 Pages

  2. ASM Series

    2 Pages

  3. ASA Series

    2 Pages

  4. XG Series

    4 Pages

  5. KDC Series

    4 Pages

  6. FX Series

    4 Pages

  7. FCS Series

    6 Pages

  8. EC1000S

    2 Pages

  9. CS Series

    4 Pages