video corpo

Compliance Testing

Compliance Testing
1 / 12 PagesView full catalog

Compliance Testing

Product catalog summary
Overview: The CTS Series by California Instruments is an advanced system designed for immunity compliance testing, particularly for products sold in Europe and Japan. It offers high sampling rates and data transfer speeds to meet international regulatory requirements for emissions and immunity.
Key Features:
  • Integrated System: Utilizes direct PC bus access for high-speed data acquisition, surpassing traditional IEC test systems.
  • Global Standards Support: Complies with European and Japanese standards, providing a comprehensive solution for AC and DC powered products.
  • Easy-to-Use Interface: Offers real-time data display, continuous PASS/FAIL monitoring, and generates reports in MS Word and Excel formats.
  • Modular System Components: Available in various power levels, supporting single and three-phase operations.
Compliance Testing:
  • Supports a range of EN/IEC standards for harmonics, flicker measurement, AC voltage dips, and more.
  • Certified by the National Physics Laboratory (NPL) for full compliance with IEC Harmonics and Flicker standards.
Cost-Effectiveness and Upgradability: The system is designed to be cost-effective and upgradable, allowing for future enhancements without significant hardware changes.
Instrument Control Software: Includes Windows-based software for easy access to power source capabilities, supporting various functions like waveform generation and harmonic measurements.
Harmonics Analyzer: Provides detailed voltage and current analysis, ensuring compliance with IEC 61000-4-7 standards.
Flicker Reference Impedance: Implements IEC 60725 compliant reference impedance, supporting different national standards.
Test Reports and Data Records: Generates comprehensive test reports in MS Word format, with data stored for further analysis.
Specifications: The CTS systems support flicker tests at 230 V, 115 V, or user-specified voltages at 50 or 60 Hz. They comply with the latest IEC 61000-3-3 and IEC 61000-3-11 standards, including amendments. They offer real-time flicker results and support for various EUT types with programmable and lumped reference impedances.
Procedures: Flicker tests can be run unattended, with results displayed in real-time. The system provides a simple user interface for test setup and execution, with graphical displays of parameters like VRMS, dmax, dc, dt, and Pst. Test reports can be generated in MS Word or Open Office formats, including detailed measurement data.
Norms and Standards: The CTS systems adhere to ISO 9001:2000 standards and support a range of EN/IEC 61000-4 immunity tests. These include voltage dips, interruptions, harmonics, interharmonics, and various other tests specified by IEC standards. The systems also support avionics power test standards like Mil-Std-704 and RTCA-DO160.
Recommendations: The document suggests using the CTS system's replay mode for detailed analysis and submitting test data to California Instruments for expert review. It also recommends using the PACS unit for isolation and accurate current sensing during tests.
Specifications:
1. Voltage: Max input 1000 Vpeak, Crest factor up to 5:1, Accuracy ±0.1% ±0.05% FS ±3 mV, Resolution 10 mV, CMRR 80 dB.
2. RMS Current: Auto-ranging with ranges 4, 16, 40/75 Arms, Max input 40/75 Arms, Crest factor varies by range, Accuracy ±0.1% ±0.05% FS ±3 mA, Resolution 1 mA.
3. Power: Range 0.1 - 24,000 W, Accuracy ±0.25% ±0.25% FS ±20 mW, Resolution 0.1 W.
4. Apparent Power: Range 0.1 - 24,000 VA, Accuracy ±0.15% ±0.15% FS ±20 mVA, Resolution 0.1 VA.
5. Power Factor: Range 0.000 - ±1.000, Accuracy ±0.005, Resolution 0.001.
6. Crest Factor: Range 20:1, Accuracy ±0.005, Resolution 0.001.
7. Frequency: Range 45.0 - 65.0 Hz, Accuracy 0.01% of reading, Resolution 0.1 Hz.
8. Harmonic Analysis: Fundamental to 40th, Accuracy varies for fundamental and harmonics, Interharmonics resolution 5 Hz, Measurement window 10, 12, 16 periods, Smoothing filter 1.5 sec.
9. Flicker: Pst Range 0.5 - 5.0, Accuracy 3%, Resolution 0.01, Integration time varies.
Procedures and Standards:
- Specifications are for L-N in three-phase configurations and valid under balanced load conditions.
- Specifications are warranted over an ambient temperature range of 25°± 5° C.
- Ordering information includes various models and configurations for single and three-phase systems.
PC Requirements:
- Compatible with Windows XP/2000/Vista, recommended hardware includes a 2.0 GHz CPU, 1 GB RAM, 80 GB hard disk, and PCI slot.
- Software requirements include MS Word and Windows.
Options and Accessories:
- Various options for impedance, compliance, and synchronization are available.
- Accessories include spare PCI A/D cards and signal interface cables.
General Information:
- Specifications are subject to change without notice.
- For higher power systems, contact the factory.
- Detailed ordering information and model specifications are provided.
See more

Catalog excerpts

Compliance Testing -12

Model VA Power AC Source EN61000-4 PACS model Single Phase Systems 100-CTS AC Line none - PACS-13001iX-CTS 3000 VA 3001 > X Included with each CTS system: PACS-15001iX-CTS (-400) 5000 VA 5001 > X (-400) PACS-1 General Options: Three Phase Systems iX Series based CTS Options: C5- Cabinet 54. System installed in 19Ԕ instrument rack. Highly recommended for all three phase systems. Prex C5-ђ to standard model number to order.CIC-PC Suitable PC with preinstalled CTS and GUI software. Includes Case, keyboard, mouse, Windows and MS Word.CIC-PCX Adds 17 inch monitor and printer to CIC-PC.-RMS Rack mount...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.