TM2000 Oxygen Analyzer

TM2000 Oxygen Analyzer

TM2000 Oxygen Analyzer

Product catalog summary
Key Benefits
  • Modular design allows for easy upgrades and field service.
  • Utilizes a zirconium oxide (ZrO2) sensor that prevents failure to a zero O2 reading, ensuring process protection.
  • Optional sample bypass enhances response times and maintains sensor inlet free of dead volume.
  • Features RS-485 serial communications, 0-20/4-20 mA current outputs, and digital alarms for seamless systems integration.
Applications
  • Cryogenic gas generating systems
  • Nitrogen purity systems
  • Blanket gas analysis
  • Inert gas purity
  • Welding atmospheres
  • Air separation
  • Atmospheric oven control
  • Glove box applications
Key Markets
  • Specialty gases
  • Bulk gas
  • Ultra High Purity (UHP) gases
Performance Specifications
  • Operating range: 0.1 ppm O2 to 100% O2.
  • Accuracy: ±1% of reading or 0.02% O2 absolute for percent readings; ±2% of reading or 0.5 ppm O2 absolute for ppm readings.
  • Response time: Less than 5 seconds at 0.6 L/min.
  • Repeatability: ±0.5% of reading or 0.1% O2 absolute for percent readings; ±0.5% of reading or 0.1 ppm O2 absolute for ppm readings.
  • Ambient temperature range: -18°C to 50°C.
  • Max inlet temperature: 71°C.
  • Sample flow: 0.1 to 1.0 L/min.
  • Power requirements: 115 VAC ±10%, 50/60 Hz, 288 VA (230 VAC optional).
  • Enclosure: Indoor/Outdoor NEMA 3R.
Series 2000 Controller Unit Specifications
  • Display: Four-line by 20-character vacuum fluorescent display.
  • Analog output: Two isolated linear current outputs, fully scalable.
  • Alarms: Two independent O2 alarms, high or low selectable.
  • Diagnostics: Includes watchdog timer, service alarms, and system tests.
  • Communications: RS-485, two-way addressable.
  • Ambient temperature: -10°C to 50°C.
  • Enclosure: Standard weatherproof NEMA 4 (IP 56) wall/panel mount.
  • Power requirements: Nominal 115-230 VAC ±10%, 47-63 Hz, 75 VA max.
  • System compliance: EMC Directive 2004/108/EC; Low Voltage Directive 73/23/EEC.
Additional Information

The TM2000 Trace Oxygen Analyzer is designed to provide superior protection through quick response to process changes, particularly in cryogenic gas generating processes. It is supported by the Series 2000 Controller, which offers user-friendly software and advanced diagnostics.

See more

Catalog excerpts

TM2000 Oxygen Analyzer-1

AMETEK* PROCESS INSTRUMENTS PRODUCT DATA SHEET TM2000 Trace Oxygen Analyzer Superior protection through quick response to process change The TM2000 net oxygen (O2) analyzer protects industrial processes by quickly responding to changes using an industry-proven zirconium oxide (ZrO2) sensor. It operates within a wide range of 0.1 ppm to 100% O2, and can accurately respond from atmosphere to low ppm O2 levels in just seconds. In addition, the TM2000 can detect excess combustibles process upsets in the presence of very low ppm O2 readings. This unique benefit is particularly important in cryogenic gas generating processes, where the TM2000 can distinguish between an O2 upset condition and an excess combustibles upset condition. The TM2000 is supported by the Series 2000 Controller, which features user-friendly, menu driven software with helpful system status text messages that allow you to begin using the TM2000 quickly. Advanced software diagnostics and on-line help further simplify the use of the TM2000, which comes complete with a standard weatherproof housing. The controller can be housed separately from the sensor. KEY BENEFITS • Modular design for easy upgrades and field service • Process protection with a ZrO2 sensor that will not fail to a zero O2 reading • Optional sample bypass improves response times and keeps sensor inlet purged of dead volume • RS-485 serial communications, 0-20/4 - 20 mA current outputs, and digital alarms for systems integration B? APPLICATIONS • Cryogenic gas generating systems • Nitrogen purity systems • Blanket gas analysis • Inert gas purity • Welding atmospheres • Air separation • Atmospheric oven control • Glove box applications FI KEY MARKETS • Specialty gases • Bulk gas • UHP gases To find out more or request a quote visit our website [PRO-033] Thermox TM2000 Trace Oxygen - F-0159_V10.indd 1 28/08/2018 14

 Open the catalog to page 1
TM2000 Oxygen Analyzer-2

TM2000 Trace Oxygen Analyzer PRODUCT DATA SHEET PERFORMANCE SPECIFICATIONS Sensor Specifications SALES, SERVICE & MANUFACTURING WORLDWIDE SALES AND SERVICE LOCATIONS Canada - Alberta 2876 Sunridge Way NE Calgary AB T1Y 7H9 Tel: +1 403 235 8400 Fax: +1 403 248 3550 © 2018, by AMETEK, Inc. All rights reserved. Printed in the U.S.A. F-0159 Rev 8 (0818) One of a family of innovative process analyzer solutions from AMETEK Process PROCESS INSTRUMENTS Instruments. Specifications subject to change without notice.

 Open the catalog to page 2

All AMETEK Process Instruments catalogs and technical brochures

  1. CEM O2 TM

    2  Pages

  2. CEM Humox

    2  Pages

  3. WDG-HPIIC

    2  Pages

  4. CG1000

    2  Pages

  5. CMFA-P 2000

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.