AMETEK A PROCESS INSTRUMENTS ^ MEASURES: Moisture, hydrocarbon dew point PRODUCT DATA SHEET Dew Point TestersChanscope II & Model 13 Bureau of Mines Dew Point Testers The Chandler Bureau of Mines Dew Point Tester is a primary instrument used to measure the dew point temperature of any gas. It is rugged, portable, and can provide very repeatable results. Because it is a primary standard, the dew point tester requires no calibration and is frequently used to verify results of electronic hydrocarbon and water dew point analyzers. Hkey benefits • Meets ASTM D1142 • Portable and rugged for repeatable results • No calibration needed • RTD traceable to NIST (Chanscope II) • Easy to maintain and use • Verify fixed installation analyzers • Measure both water and hydrocarbon dew point temperatures • Capable of measurements in sour natural gas El APPLICATIONS • Natural gas pipelines • Natural gas custody transfer stations • Natural gas processing plants • Natural gas liquid separation • Industrial gases • Heat treating furnaces n KEY MARKETS • Natural gas • Steam and heat treating • Industrial gas • Refining • Chemical and petrochemical The Chandler Dew Point Tester is a chilled mirror device that operates by achieving the conditions required by the definition of dew point. A polished mirror is at one end of the chamber and a viewing window at the other. The operator controls an expandable gas through a valve, cooling the polished mirror until the dew point temperature is observed. Both moisture and hydrocarbon dew point temperature are obtained using the same method. The observed dew point temperature and pressure may be entered into the moisture content software available with the dew point tester to calculate the water content of the sample gas, such as natural gas. Accurate performance The Model 13 Bureau of Mines Dew Point Tester is the industry standard for dew point measurements, meeting ASTM D1142. Flexibility Both the Chanscope II and Model 13 are primary instruments capable of measuring both water and hydrocarbon dew point temperatures in a single analyzer, eliminating the need for (and cost of) multiple instruments. Easy to use With no electrical power required, simply connect the process gas and coolant and you are ready to perform your measurements.
Open the catalog to page 1Chanscope II Dew Point Tester © 2018, by AMETEK, Inc. All rights reserved. Printed in the U.S.A. F-0168 Rev 8 (0818) One of a family of innovative process analyzer solutions from AMETEK Process PROCESS INSTRUMENTS Instruments. Specifications subject to change without notice.
Open the catalog to page 2All AMETEK Process Instruments catalogs and technical brochures
-
NATURAL GAS SOLUTIONS
11 Pages
-
Ranarex Gas Gravitometers
2 Pages
-
Dew Point Tester
2 Pages
-
MGB1000 Micro Gas Blender
2 Pages
-
Dymaxion Mass Spectrometer
4 Pages
-
Remote Calibration Unit
2 Pages
-
WDG-VRM Oxygen Analyzer
2 Pages
-
WDG-VCM Flue Gas Analyzer
2 Pages
-
TM2000 Oxygen Analyzer
2 Pages
-
HAG Sampling Probe
2 Pages
-
5100 CO2 Gas Analyzer Atex
2 Pages
-
932 Multi Gas Analyzer
2 Pages
-
919 Hot Wet Gas Analyzer
2 Pages
-
910 Hot Wet Multi Gas CEM
2 Pages
-
9900RM/9900WM Gas Analyzers
2 Pages
-
931 Single Gas Analyzer
2 Pages
-
920 Multi Gas Analyzer
2 Pages
-
934 Single-Gas Analyzer
2 Pages
-
Ranarex Gravitometer
2 Pages
-
303B Moisture Analyzer
2 Pages
-
5920 UHP Moisture Analyzer
2 Pages
-
5910 UHP Moisture Analyzer
2 Pages
-
5830 Moisture Analyzer
2 Pages
-
5812 Moisture Analyzer
2 Pages
-
5800 Moisture Analyzer
2 Pages
-
2850 Moisture Analyzer
2 Pages
-
5100 CO2 Gas Analyzer
2 Pages
-
5000 Sample System
2 Pages
-
5000 Analyzer Controller
2 Pages
-
5000 Moisture Analyzer
2 Pages
-
3050-TE Moisture Analyzer
2 Pages
-
3050-AP Moisture Analyzer
2 Pages
-
3050-AM Moisture Analyzer
2 Pages
-
WDG 1200 1210 Insitu
2 Pages
-
CEM O2 TM
2 Pages
-
CEM Humox
2 Pages
-
TM2000 Trace Oxygen Analyzer
2 Pages
-
CEM O2 Analyzer
2 Pages
-
WDG-HPIIC
2 Pages
-
CG1000
2 Pages
-
CMFA-P 2000
2 Pages
-
ta5000 Gas Analyzers
2 Pages
-
ta3000 Gas Analyzers
2 Pages