CG1000

CG1000

CG1000

Product catalog summary
Overview: The CG1000 is a portable oxygen analyzer designed for industrial and laboratory applications. It offers a wide operating range from 0.1 ppm to 100% O2 and features fast response times, advanced electronic capabilities, and easy integration into control systems.
Key Benefits:
  • Fast response time of less than 5 seconds over one decade.
  • Fails safe to air instead of reading zero O2.
  • Reliable monitoring of sample flow with reduced calibration expenses.
  • Easy integration via digital communications and analog outputs.
  • Specialized models available for rapid thermal processing (RTP).
Applications: The CG1000 is suitable for various applications including rapid thermal processing, air separation, inert gas purity analysis, blanket/purge gas analysis, glove box applications, cryogenic gas generation, atmospheric oven/furnace control, and UV curing ovens.
Key Markets: The analyzer is targeted at sectors such as semiconductors, specialty welding, pharmaceuticals, fiber optics, polymers, and graphite and carbon fiber industries.
Performance Specifications:
  • Operating range: 0.1 ppm O2 to 100% O2.
  • Accuracy: ±2% of reading or 0.05% O2 absolute.
  • Response time: Less than 5 seconds at 150 sccm over one decade.
  • Repeatability: ±0.5% of reading or 0.1% O2 absolute.
  • Environment: Ambient temperature 5 to 40°C, relative humidity 10 to 80% non-condensing.
  • Sample flow: 50 to 200 sccm, factory-calibrated at 150 sccm.
  • Power requirements: 115 VAC, 60 Hz, 150 VA or 230 VAC, 50 Hz, 150 VA.
Features:
  • Lightweight and portable with a compact case and handle.
  • User-friendly with menu-driven software and system status messages.
  • Reliable monitoring with an electronic flow sensor and optional built-in pump.
  • Advanced diagnostics and online help for simplified operations.
Communication and Outputs:
  • RS485, 2-way addressable communication.
  • Two isolated linear current outputs, fully scalable.
  • Two independent alarms, high or low selectable.
Compliance and Dimensions:
  • Complies with EMC Directive 89/336/EEC and Low Voltage Directive 73/23/EEC.
  • Dimensions: 202 x 273 x 406 mm, weight approximately 8.6 kg.
Contact Information: For more information or to request a quote, visit ametekpi.com or contact their worldwide sales and service locations.
See more

Catalog excerpts

CG1000-1

AMETEK PROCESS INSTRUMENTS PRODUCT DATA SHEET CG1000 Oxygen AnalyzerQuickly responds to net oxygen changes from 0.1 ppm to 100% O2 The CG1000 is a portable oxygen (O2) analyzer for industrial and laboratory applications. It has a wide operating range (0.1 ppm to 100% O2, auto-ranging), a fast response to O2 changes, and advanced electronic capabilities for easy system integration. Lightweight A compact case with handle makes it easy to move the analyzer to different sampling locations. KEY BENEFITS • Fast response of <5 sec over 1 decade • Fails safe to air instead of reading zero O2 • Reliably monitors sample flow • Calibrated on % gases to read low ppm, reducing calibration expenses • Easily integrated into control schemes via digital communications & analog outputs • Available in specialized models for RTP User-friendly Menu-driven software includes helpful system status messages, allowing you to begin using the CG1000 quickly. Advanced software diagnostics and online help simplify operations. Reliable monitoring An electronic flow sensor eliminates the high maintenance and potential leaks associated with mechanical flow meters, allowing you to reliably monitor the flow of gases into the analyzer, and can even trigger a flow alarm if flow to the analyzer stops. Also, an optional built-in pump allows samples to be pulled from processes under vacuum and compensates for pressure when measuring O2 under vacuum. APPLICATIONS • Rapid thermal processing (RTP) • Air separation • Inert gas purity (N2, Ar, CO2, He, etc.) • Blanket/purge gas analysis • Glove box applications • Cryogenic gas generation • Atmospheric oven/furnace control • UV curing ovens FI KEY MARKETS • Semiconductor • Specialty welding • Pharmaceutical • Fiber optics chemical carbon fiber

 Open the catalog to page 1
CG1000-2

PERFORMANCE SPECIFICATIONS 1. All static performance characteristics are with operating variables constant. 2. System accuracy referenced to 0.1 to 10% calibrated range. © 2019, by AMETEK, Inc. All rights reserved. Printed in the U.S.A. F-0222 Rev 7 (0219) One of a family of innovative process analyzer solutions from AMETEK Process Instruments. PROCESS INSTRUMENTS Specifications subject to change without notice.

 Open the catalog to page 2

All AMETEK Process Instruments catalogs and technical brochures

  1. CEM O2 TM

    2  Pages

  2. CEM Humox

    2  Pages

  3. WDG-HPIIC

    2  Pages

  4. CMFA-P 2000

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.