Key Benefits
  • Suitable for wet or dry gas environments.
  • Compact design.
  • User-friendly operation.
Applications
  • Continuous Emission Monitoring (CEM) systems.
  • Wet or dry oxygen (O2) measurement.
Key Markets
  • Industrial sectors requiring emissions monitoring.
Product Overview

The CEM/Oxygen Analyzer is designed for extractive net oxygen analysis in both wet and dry gas conditions. It is cost-effective and integrates advanced features for emissions monitoring systems. The analyzer meets 40 CFR Part 60 and Part 75 Federal EPA performance specifications and regional O2 monitor requirements.

Technical Specifications
  • Sensor Specifications: Utilizes zirconium oxide (ZrO2) with an operating range of 0.1-100% O2. Accuracy is ±0.75% of reading or 0.05% O2, with a response time of less than 4 seconds.
  • Environmental Conditions: Operates in ambient temperatures from -18 to 50°C and relative humidity of 10-90% (non-condensing).
  • Power Requirements: 115 VAC or 230 VAC, 47-63 Hz, 1670 VA max.
Series 2000 Control Unit
  • Features a four-line display, analog outputs, alarms, and RS485 communication.
  • Includes optional Humox O2 wet/dry calculation software.
  • Provides diagnostics and supports autocalibration.
Performance Specifications
  • Max inlet temperature: 204°C (400°F).
  • Sample pressure: ±2 psig max.
  • Sample flow: 2 to 20 scfh.
Compliance and Certifications
  • Complies with EMC directive 89/336/EEC and low voltage directive 73/23/EEC.
  • UL Listed for NEC Class I, Division 2 areas.
Contact Information

For more information or to request a quote, visit ametekpi.com or contact their offices in the USA, Canada, Brazil, France, China, Germany, India, and Singapore.

See more

Catalog excerpts

CEM O2 Analyzer-1

AMETEK PROCESS INSTRUMENTS PRODUCT DATA SHEET Hkey benefits • Wet or dry gas • Small footprint • Easy to operate E APPLICATIONS • CEM system • Wet or dry O2 measurement FI KEY MARKETS • Industrial CEM/Oxygen Analyzer Extractive net oxygen (O2) analyzer for use in a wet or dry gas continuous emission monitoring (CEM) system or instrument cabinet For applications where a sample is taken to a remote analyzer location, the cost-effective CEM/O2 analyzer provides advanced system features that integrate into your overall emissions monitoring system. The analyzer complies with 40 CFR Part 60 and Part 75 Federal EPA performance specification requirements along with regional requirements for O2 monitors. Extractive analyzers Extractive analyzers are located remotely from the sample point. The sample can be delivered to the analyzer through a heated sample line (hot or wet) or cooled to remove the moisture (dry). With zirconium oxide (ZrO2), either method can be used. Most of the sample passes straight through the analyzer. A portion flows into the convection loop and is measured by the O2 cell. Series 2000 control unit Series 2000 microprocessor control provides four-line local display, analog outputs, alarms, expanded system diagnostics, autocalibration option, RS485 communication, and optional Humox O2 wet/dry calculation software for correlated flue gas moisture measurement. To find out more or request a quote visit our website ametekpi.com

 Open the catalog to page 1
CEM O2 Analyzer-2

CEM/Oxygen Analyzer PRODUCT DATA SHEET PERFORMANCE SPECIFICATIONS Sensor Specifications SALES, SERVICE & MANUFACTURING WORLDWIDE SALES AND SERVICE LOCATIONS © 2018, by AMETEK, Inc. All rights reserved. Printed in the U.S.A. F-0381 Rev 5 (0818) One of a family of innovative process analyzer solutions from AMETEK Process PROCESS INSTRUMENTS Instruments. Specifications subject to change without notice. To find out more or request a quote visit our website rX ametekpi.com PRO-054_Model CEM O2 Analyzer - F-0381 V3.indd 2