CEM Humox

CEM Humox

CEM Humox

Product catalog summary
Key Benefits
  • Continuous emissions monitoring (CEMS) with options for hot wet or cold dry extractive methods.
  • Software for O2 wet/dry calculation to measure flue gas moisture.
Applications
  • Emissions and compliance monitoring.
  • Instrumentation panels for CEMS.
Key Markets
  • Continuous Emissions Monitoring Systems (CEMS).
  • Measurement of stack moisture and O2 wet/dry levels.
Product Overview

The CEM Humox analyzer measures moisture and oxygen content in flue gas using two sensors (one for dry and one for wet samples) and a Series 2000 control unit. It helps in emissions correction, product quality assurance, and minimizing stack corrosion.

Extractive Analyzers

These analyzers are remotely located from the sample point and can handle samples delivered through heated lines or cooled to remove moisture. They use zirconium oxide (ZrO2) for measurement.

Performance Specifications
  • Sensor Specs: Operating range for O2 is 0.1% to 100%, and for moisture, 5% to 85% by volume. Accuracy for O2 is ±0.75% of reading or ±0.05% absolute, and for moisture, ±3% of reading or ±1% absolute.
  • Response Time: Less than 4 seconds at 2 scfh over one decade.
  • Max Inlet Temperature: 400°F (204°C).
  • Sample Flow: 0.1 to 1.0 L/min (0.6 L/min recommended).
  • Environment: Ambient temperature range from -18°C to 50°C (0°F to 122°F), with relative humidity from 10% to 90%, noncondensing.
  • Power Requirements: 115 VAC or 230 VAC, ±10%, 47-63 Hz, 313 VA max.
  • Enclosure: Indoor use only.
Series 2000 Control Unit Specs
  • Display: Four-line x 20-character vacuum fluorescent display with various data outputs and user programmable text.
  • Analog Output: Three isolated linear current outputs, fully scalable.
  • Alarms: Four independent sensor alarms, configurable for high or low settings.
  • Diagnostics: Includes watchdog timer, service alarms, and system tests.
  • Communications: RS-485 2-way addressable.
  • Environment: Ambient temperature from 14 to 122°F (-10 to 50°C), with relative humidity from 10% to 80%, noncondensing.
  • Enclosure Options: Various mounting options, all UL Listed for NEC Class I, Division 2 areas.
  • Calibration: Features for extending oxygen cell lifetime and automatic calibration options.
  • Power Requirement: 115-230 VAC ±10%, 47-63 Hz, 75 VA max.
  • Compliance: Meets EMC Directive 2004/108/EC and Low Voltage Directive 73/23/EEC.
See more

Catalog excerpts

CEM Humox-1

AMETEK PROCESS INSTRUMENTS PRODUCT DATA SHEET CEM Humox Measurement of moisture in flue gas The CEM/Humox moisture in flue gas analyzer consists of two CEM/Oxygen (O2) sensors (one dry and one wet) and a special version of the Series 2000 control unit. It is designed to measure net O2 and moisture content in flue gas and process applications to calculate emissions on a dry or wet basis. The O2 and moisture data is used to correct emissions, assure product quality, or minimize stack corrosion. The analyzer indicates moisture, O2 wet and O2 dry concentrations in percent by volume. Extractive analyzers Extractive analyzers are located remotely from the sample point. The sample can be delivered to the analyzer through a heated sample line (hot or wet) or cooled to remove the moisture (dry). With zirconium oxide (ZrO2) either method can be used. Most of the sample passes straight through the analyzer. A portion flows into the convection loop and is measured by the O2 cell. ■key benefits • Hot Wet or Cold Dry extractive continous emissions monitoring (CEMS) • O2 wet/dry calculation software for correlated flue gas moisture measurement B5 APPLICATIONS • CEMS • Hot Wet extractive CEMS • Emissions and compliance • Instrumentation panels FI KEY MARKETS • CEMS • Stack moisture (O2 wet/dry) Model CEM Humox for Moisture - F-0155.indd 1 09/08/2018 11:38

 Open the catalog to page 1
CEM Humox-2

PRODUCT DATA SHEETPERFORMANCE SPECIFICATIONS Sensor Specs SALES, SERVICE & MANUFACTURING WORLDWIDE SALES AND SERVICE LOCATIONS Canada - Alberta 2876 Sunridge Way NE Calgary AB T1Y 7H9 Tel: +1 403 235 8400 Fax: +1 403 248 3550 © 2018, by AMETEK, Inc. All rights reserved. Printed in the U.S.A. F-0155 Rev 10 (0818) One of a family of innovative process analyzer solutions from AMETEK Process Instruments. PROCESS INSTRUMENTS Specifications subject to change without notice. Model CEM Humox for Moisture - F-0155.indd 2

 Open the catalog to page 2

All AMETEK Process Instruments catalogs and technical brochures

  1. CEM O2 TM

    2  Pages

  2. WDG-HPIIC

    2  Pages

  3. CG1000

    2  Pages

  4. CMFA-P 2000

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.